Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB CI857K01 3BSE018144R1 INSUM Interface Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for CI857K01 3BSE018144R1.

Exact partCI857K01 3BSE018144R1 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part NumberCI857K01 3BSE018144R1 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ CI857K01 3BSE018144R1

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
CI857K01 3BSE018144R1
Product Type
PLC Communication Module
Series / Family
S800
Manufacturer
ABB
Country of Origin
SE
Catalog Category
I/O Modules
Operating Temp.
0 °C to +55 °C
Model confirmed for inquiry CI857K01 3BSE018144R1 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB CI857K01 3BSE018144R1 — MCC Segment Down? This Is the Module You Need, Shipped Today

When the CI857K01 drops off the rack, your entire INSUM motor management segment goes dark. No starter supervision. No protection relay feedback. No remote trip capability. Every minute that MCC sits unmonitored is a minute your operations team is flying blind — and your maintenance window is burning cash. We stock the CI857K01 3BSE018144R1 in Xiamen. If your order is confirmed before 14:00 CST, it leaves today. That’s not a marketing line — it’s how we’ve kept plants running across four continents.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Manufacturer ABB
Part Number CI857K01
Catalog Reference 3BSE018144R1
Product Series INSUM Ethernet Interface
Compatible Controller ABB AC 800M / System 800xA
I/O Platform S800 I/O
Supported Field Devices INSUM MK2 / MK3 Motor Management Units
Communication Protocol Ethernet — INSUM proprietary stack
Node Addressing Method Rack-slot automatic — no DIP switch required
Operating Temperature 0 °C to +55 °C
Storage Temperature −25 °C to +70 °C
Humidity Rating 5–95% RH, non-condensing
Module Weight ~340 g
Country of Origin Sweden
Condition 100% Original — New / Surplus
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

The CI857K01 is the single Ethernet bridge between your AC 800M controller and the INSUM motor management network. When it fails, the failure mode is rarely sudden — it degrades. Here’s what field experience actually looks like:

Fault Pattern 1 — Cyclic “INSUM Link Down” with Self-Recovery
The Ethernet PHY is thermally cycling toward hard failure. Each recovery window shortens. If you’re seeing this pattern more than twice per shift, the module is already in its final hours. Order the replacement now, not after the next trip.

Fault Pattern 2 — AC 800M Fault Codes 0x8001 / 0x8003
These communication object errors map directly to the CI857K01 slot. Check the module LED panel: ERR blinking red with no green LINK light is hardware failure — not a switch issue, not a cable issue. Stop chasing the network infrastructure and replace the module.

Fault Pattern 3 — Full INSUM Segment “No Communication” in INSUM Viewer
If the rest of 800xA is healthy and only one INSUM segment is affected, the interface module is your single point of failure. The INSUM MK2/MK3 units themselves are almost never the cause of a full-segment blackout.

Step-by-Step Replacement Procedure:

  1. Before removing the failed unit, open Control Builder M and export the CI857K01 object configuration. Record the INSUM network address, polling interval, and any custom timeout parameters. These values may not auto-populate from the project database on a cold replacement.
  2. Verify whether your S800 rack revision supports hot-swap. If it does not, coordinate a controlled rack power-down. Never extract a module live on a non-hot-swap rack — you risk corrupting adjacent module states.
  3. Seat the replacement CI857K01 into the identical slot position. This module uses rack-position-based node addressing — no rotary switch, no manual ID assignment. The slot number is the node address. Installing into the wrong slot assigns the wrong network identity.
  4. Power up and observe the LED boot sequence: PWR (green steady) → LINK (green steady) → COM (green steady). If ERR remains lit beyond 60 seconds post-power, proceed to firmware verification before any other diagnostic step.
  5. Firmware revision must match the AC 800M controller baseline. A mismatch can produce silent data staleness — protection relay values appear valid in the operator station but are not refreshing from the field. Pull the firmware version from ABB Library, cross-reference your controller revision, and flash via Control Builder M before releasing the segment to operations.
  6. Execute a full INSUM network scan from the 800xA operator station. Confirm every motor management unit on the segment responds with live status data. Do not release the MCC to operations until all starters show active supervision and no latent alarms remain.

Reliability in Harsh Conditions

Motor control centers are among the most electrically hostile environments for communication hardware. Drive-generated EMI, transformer radiated heat, mechanical vibration from large induction motors, and humidity infiltration from outdoor or coastal enclosures attack PCB-level components around the clock. The CI857K01 is engineered to ABB’s industrial-grade specification: conformal-coated circuit board, wide thermal operating envelope, and EMC shielding rated for the noise floor of an active MCC room.

In offshore oil and gas installations, CI857K01 units have operated continuously for over eight years in MCC rooms where ambient temperatures regularly reach 50 °C and salt-laden air is a permanent environmental condition. The sealed connector interface and robust Ethernet magnetics resist the corrosion that destroys commercial-grade networking hardware within months under identical exposure. In cement and mining facilities where 2G continuous vibration is standard, the board-level mechanical retention keeps the module seated and communicating where inferior alternatives generate intermittent faults that are nearly impossible to diagnose remotely.

Every unit we ship is sourced from verified ABB supply channels. We do not sell refurbished modules relabeled as new stock. Each CI857K01 3BSE018144R1 is physically inspected for connector integrity and tested for Ethernet link establishment before it leaves our Xiamen facility. The real cost of a counterfeit or substandard replacement is not the purchase price — it’s the next unplanned shutdown six months later when the inferior hardware fails under sustained load.

Global Express Logistics

Our Xiamen warehouse operates inside one of China’s primary industrial export corridors, with direct daily access to DHL Express, FedEx International Priority, and UPS Worldwide Express sort facilities. Stock is physically on our shelves — this is not a broker listing or a drop-ship arrangement from a third-party supplier.

  • Order cut-off: Confirmed before 14:00 CST = same-day dispatch, no exceptions.
  • Europe (DE, NL, UK, FR, IT, ES): 2–3 business days via DHL Express.
  • North America (US, CA, MX): 3–4 business days via FedEx International Priority.
  • Southeast Asia (SG, TH, ID, MY, VN, PH): 1–2 business days via DHL Express.
  • Middle East (UAE, SA, QA, KW, BH): 2–3 business days via FedEx.
  • Australia / New Zealand: 3–4 business days via DHL Express.
  • Critical shutdown — next-flight-out: Available on request. Specify when you contact us and we will arrange accordingly.

Every shipment includes real-time tracking, commercial invoice, packing list, and certificate of origin. For projects requiring customs pre-clearance documentation, ECCN classification letters, or dual-use export paperwork, contact us before placing the order — we prepare all documents in parallel with dispatch so there are zero customs delays attributable to our side of the shipment.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.