Schneider Electric BMENOC0301 Ethernet Communication Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for BMENOC0301.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Schneider Electric
- Primary Part Number
- BMENOC0301
- Product Type
- Ethernet Communication Module
- Series / Family
- Modicon M580
- Country of Origin
- FR
- Catalog Category
- Communication
- Operating Temp.
- 0 °C to +60 °C
BMENOC0301 Down? Every Minute of Downtime Costs You Money — We Ship Same Day
Your M580 rack just threw a communication fault. The HMI is blank, the SCADA historian has flatlined, and your process engineer is standing behind you. You don’t need a datasheet right now — you need a module on a plane. The Schneider Electric BMENOC0301 Ethernet Network Communication Module is in stock at our Xiamen warehouse. We cut the paperwork, pull the unit, test it, and hand it to DHL before your shift ends.
We’ve handled enough emergency callouts to know that a 48-hour wait for a communication module can translate directly into six-figure production losses. That’s why siemensplc.com maintains buffer stock of high-turnover M580 components specifically for unplanned outages. No minimum order. No lengthy RFQ cycle. One email or WhatsApp message and we move.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | BMENOC0301 |
| Brand | Schneider Electric |
| Platform | Modicon M580 ePLC |
| Module Function | Ethernet Network Communication Module |
| Ethernet Ports | 3 × RJ45 (embedded managed switch) |
| Supported Protocols | EtherNet/IP, Modbus TCP/IP, SNMP, FTP, HTTP |
| Data Rate | 10/100 Mbps, auto-negotiation |
| Topology | Ring (DLR), Star, Daisy-chain |
| Backplane Power | Rack-supplied — no external PSU required |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5% to 95%, non-condensing |
| Protection Rating | IP20 |
| Certifications | CE, UL, cUL, RCM |
| Programming Software | EcoStruxure Control Expert (Unity Pro) v13.0+ |
| Country of Origin | France |
| Stock Status | Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
The BMENOC0301 fails in predictable ways. Here is what shows up most often on site and how to handle the swap without creating a second problem.
Common Fault Indicators
- ERR LED solid red: Module has lost backplane communication or firmware is corrupted. Power-cycle the rack first — if ERR persists after 30 seconds, the module is the culprit, not the CPU.
- ETH port link LEDs dark with cable confirmed good: Internal switch ASIC failure. No field repair possible — replace the module.
- SCADA losing tags intermittently every 30 to 90 minutes: Check the module IP conflict log via the embedded web server. Browse to the module IP on port 80. A duplicate IP on the plant network is the number one cause of this symptom.
- Control Expert shows Module not responding after firmware update: The BMENOC0301 requires a cold boot — full rack power-off, not just CPU reset — after any firmware flash. Miss this step and the module stays in bootloader mode.
Replacement Procedure — Field Checklist
- Document the existing module IP address, subnet mask, gateway, and DHCP setting from the embedded web server before pulling the unit.
- Export the Control Expert project and note the NOC slot position. The replacement must go into the exact same slot number or you will need to re-rack the I/O map.
- The BMENOC0301 uses auto-addressing via the backplane. The CPU assigns the module address automatically based on slot position. No rotary switch or DIP switch setting is required. This is a common point of confusion for engineers coming from M340 or Quantum backgrounds.
- After seating the new module, perform a cold boot. Wait for the RUN LED to go green before attempting to reconnect Control Expert.
- Firmware version must match or exceed the version on the failed unit. Check the project hardware catalog version in Control Expert. Mismatched firmware will cause a Hardware mismatch fault on the CPU.
- If replacing with a BMENOC0311, the module is functionally compatible but requires a hardware catalog update in Control Expert before download. Do not attempt a direct swap without updating the project file first.
Reliability in Harsh Conditions
The BMENOC0301 was not designed for a climate-controlled server room. Schneider Electric built it for the realities of process industry environments — and those realities are unforgiving.
The module’s conformal-coated PCB resists moisture ingress and condensation cycles common in coastal chemical plants and offshore platforms. The embedded switch ASIC is rated for continuous operation at 60 °C ambient, handling the thermal load inside a sealed enclosure on a summer afternoon in Southeast Asia without throttling. Vibration tolerance meets IEC 60068-2-6 sinusoidal and IEC 60068-2-27 shock, covering the mechanical stress profiles of compressor skids, pump stations, and mobile equipment installations.
The three-port managed switch architecture means a cable fault on one Ethernet segment does not propagate to the others — a critical design feature for ring topologies where a single break must not take down the entire I/O network. DLR Device Level Ring supervisor capability is built in, so the module manages ring healing autonomously without a separate managed switch in the field panel.
Units supplied by siemensplc.com are inspected for physical damage, corrosion on the backplane connector, and firmware version before dispatch. Modules with bent pins or oxidized contacts go straight to the reject bin — they do not ship.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. Here is how a typical emergency order moves.
- Order confirmed before 14:00 CST: Same-day dispatch via DHL Express or FedEx International Priority, depending on destination country customs clearance profile.
- Transit times: Southeast Asia 1 to 2 business days. Europe 3 to 4 business days. North America 3 to 5 business days. Middle East and Africa 4 to 6 business days.
- Documentation: Commercial invoice, packing list, and certificate of conformity issued with every shipment. HS code 8537.10 declared for customs. We handle export licensing — no action required from your side.
- Tracking: AWB number sent within 2 hours of dispatch. Real-time tracking link provided via email and WhatsApp.
- Customs clearance: Shipments are pre-cleared with accurate declared values. We do not under-declare — this protects your import compliance record.
- Emergency freight: For critical shutdowns, door-to-door courier with airport-to-airport handoff is available for destinations not served by standard express lanes. Contact us directly to arrange.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.