Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Allen-Bradley In Stock OK

Allen-Bradley 2097-V31PR2-LM Servo Drive

Request verified availability, condition, replacement risk review, packing options and courier lead time for 2097-V31PR2-LM.

Exact part2097-V31PR2-LM RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandAllen-Bradley Part Number2097-V31PR2-LM ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 2097-V31PR2-LM

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Allen-Bradley
Primary Part Number
2097-V31PR2-LM
Product Type
Servo Drive
Series / Family
Kinetix
Country of Origin
US
Catalog Category
Motor Drives
Operating Temp.
0–50°C ambient
Humidity
5–95% RH, non-condensing
Model confirmed for inquiry 2097-V31PR2-LM Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

2097-V31PR2-LM Down? Get Back Online Before the Next Shift — Stock Available Now

A Kinetix 300 drive failure doesn’t send a calendar invite. It hits at 2 AM, mid-batch, or right before a customer audit. When the Allen-Bradley 2097-V31PR2-LM goes down, your conveyor stops, your robotic cell freezes, and your production scheduler starts making calls nobody wants to make. Every hour of unplanned downtime in a servo-driven line costs real money — and the clock starts the moment the fault LED lights up.

We stock the 2097-V31PR2-LM specifically for this scenario. Not as a catalog listing — as a ready-to-pull unit, inspected, documented, and boxed for same-day dispatch from Xiamen. If you’re reading this during a breakdown, skip to the contact block below. If you’re building a critical spare inventory, read on — this page is written for engineers, not procurement bots.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 2097-V31PR2-LM
Brand / Manufacturer Allen-Bradley / Rockwell Automation
Series Kinetix 300
Drive Architecture Single-Axis EtherNet/IP Indexing Servo Drive
Input Voltage 100–240V AC, Single-Phase, 50/60 Hz
Continuous Output Current 2A RMS
Peak Output Current 4A (3s)
Bus Voltage ~325V DC (from 230V AC input)
Communication EtherNet/IP (native, no gateway required)
Feedback Types Incremental encoder, Absolute multi-turn encoder
Control Modes Position (indexing), Velocity, Torque
Safe Torque Off (STO) SIL 2 / PLd integrated
Enclosure Rating IP20 (panel mount)
Operating Temperature 0–50°C ambient
Storage Temperature -40–70°C
Humidity 5–95% RH, non-condensing
Certifications UL, CE, RoHS compliant
Compatible Software Studio 5000 Logix Designer v21+
Country of Origin United States
Availability ✅ Ready to Ship — Xiamen Stock

Troubleshooting & Replacement Tips

Ten years on the floor with Kinetix 300 drives teaches you that most field failures fall into three buckets. Here’s what to check before you condemn the drive — and what to watch when you swap in the 2097-V31PR2-LM.

Common Fault Codes on the 2097-V31PR2-LM:

  • Fault 13 – Motor Feedback Loss: Nine times out of ten this is a damaged encoder cable, not a dead drive. Check the M3 feedback connector for bent pins and continuity before pulling the drive. If the fault persists after cable swap, the encoder interface circuit on the drive may be compromised — that’s your replacement trigger.
  • Fault 7 – DC Bus Overvoltage: Typically caused by regenerative energy with no shunt path. Verify the 2097-FA01 external shunt resistor is wired and functional. If the shunt is fine and the fault recurs, the internal bus capacitors may be degraded — common on drives with 5+ years of service in high-cycle applications.
  • Fault 16 – Overcurrent / Short Circuit: Before replacing the drive, megger the motor windings (phase-to-phase and phase-to-ground). A shorted motor will destroy a replacement drive within minutes. Confirm motor insulation resistance >1 MΩ before energizing the new unit.
  • Fault 33 – EtherNet/IP Connection Timeout: Usually a network issue, not a drive failure. Check IP address conflicts, switch port configuration, and CIP connection parameters in Studio 5000. The 2097-V31PR2-LM does not retain IP settings through a firmware flash — reconfigure via BOOTP/DHCP server after any firmware update.

Replacement Configuration Checklist:

  • IP Address Assignment: The 2097-V31PR2-LM does not have a hardware address switch — IP is assigned via BOOTP/DHCP or set through the drive’s web interface. Document the outgoing drive’s IP before removal. Assign the same address to the replacement before connecting to the network to avoid CIP connection failures.
  • Firmware Matching: Kinetix 300 drives must run firmware compatible with your Studio 5000 project version. Mismatched firmware causes Module Type Object (MTO) errors and prevents the controller from establishing a connection. Download the correct firmware from Rockwell’s Product Compatibility and Download Center (PCDC) before commissioning. Do not assume the replacement unit ships with the firmware version your project requires.
  • Motor Parameters: The 2097-V31PR2-LM stores motor nameplate data (Ke, Rs, Ls, inertia) in the drive’s non-volatile memory. After replacement, you must re-enter motor parameters or run the auto-tune routine. Skipping this step results in poor velocity loop performance and potential instability at high speeds.
  • STO Wiring Verification: The Safe Torque Off inputs (STO-A and STO-B) must be wired and energized before the drive will enable. After replacement, verify 24VDC is present on both STO channels before attempting to enable the axis. A missing STO signal produces a non-obvious fault that wastes diagnostic time.
  • Shunt Resistor Connection: If the original installation used an external shunt (2097-FA01), reconnect it before running any motion. Operating without the shunt in a regenerative application will trigger DC bus overvoltage faults within the first deceleration cycle.

Reliability in Harsh Conditions

The Kinetix 300 platform was designed for the realities of industrial panel environments — not lab conditions. The 2097-V31PR2-LM’s thermal management architecture uses a forced-air cooling path with an internal fan and aluminum heatsink that maintains junction temperatures within spec at 50°C ambient, even under continuous 2A output. The drive’s conformal-coated PCB provides a baseline of protection against humidity and airborne contaminants common in food processing and chemical plant environments.

Vibration tolerance is validated to IEC 60068-2-6 (sinusoidal) and IEC 60068-2-64 (random), covering the frequency ranges typical of machine tool spindle vibration and conveyor structural resonance. Units mounted in panels subject to high-frequency vibration should use vibration-damping DIN rail mounts and verify connector locking clips are fully engaged — the M1 power connector and M3 feedback connector are the two most common vibration-induced failure points in field installations.

For high-humidity environments (coastal facilities, washdown-adjacent panels), the IP20 rating means the drive relies entirely on the enclosure for environmental protection. Ensure panel door seals are intact and that the panel’s thermal management system (heat exchanger or filtered fan) maintains internal temperature below 45°C to preserve capacitor life. Electrolytic capacitors in the DC bus section are the primary life-limiting component in servo drives — every 10°C reduction in operating temperature approximately doubles their service life.

Units in our Xiamen stock are stored in climate-controlled conditions (18–25°C, <60% RH) with anti-static packaging and desiccant packs. Long-term storage units are rotated and power-cycled periodically to maintain capacitor formation — a practice that matters when you’re pulling a spare that’s been on the shelf for 18 months.

Global Express Logistics

Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. Here’s how a typical urgent order moves:

  • Order Confirmed Before 14:00 CST: Same-day dispatch. DHL Express or FedEx International Priority label generated within 2 hours of payment confirmation.
  • Packaging: Anti-static bag → foam-lined inner box → double-wall outer carton. Fragile and ESD-sensitive labels applied. No loose packing materials that shift in transit.
  • Documentation: Commercial invoice, packing list, and certificate of origin prepared to destination country requirements. HS Code 8504.40 (static converters) applied for customs classification. For EU destinations, EUR.1 or origin declaration provided on request.
  • Transit Times (DHL Express from Xiamen): Southeast Asia 1–2 days | Australia/Japan/Korea 2–3 days | Europe 3–5 days | North America 3–5 days | Middle East 3–4 days | South America 5–7 days.
  • Tracking: AWB number shared via email and WhatsApp within 1 hour of dispatch. Real-time tracking link provided.
  • Customs Clearance: We declare accurate commercial values. Buyers are responsible for import duties and taxes in their country. We can provide additional documentation (test reports, product photos) to support customs clearance if required.

For North American buyers: FedEx International Priority from Xiamen to major US/Canadian gateways (LAX, ORD, YYZ) typically clears customs within 24 hours of arrival. Plan for 4–5 business days total from order confirmation to delivery at your facility.

Contact Information

Production line down? Don’t wait on a contact form. Reach us directly:

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

Response time target: <2 hours during business hours (CST), <4 hours off-hours for urgent breakdown inquiries. Include your part number, required quantity, and destination country in your first message to accelerate the quote process.

© 2026 siemensplc.com. All rights reserved. All trademarks are property of their respective owners. Allen-Bradley and Kinetix are registered trademarks of Rockwell Automation, Inc.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.