Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Omron In Stock OK

OMRON ITNC-EIS01-DRM Open Network Controller

Request verified availability, condition, replacement risk review, packing options and courier lead time for ITNC-EIS01-DRM.

Exact partITNC-EIS01-DRM RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandOmron Part NumberITNC-EIS01-DRM ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ ITNC-EIS01-DRM

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Omron
Primary Part Number
ITNC-EIS01-DRM
Product Type
Open Network Controller
Product Family
Other series
Manufacturer
OMRON Corporation
Country of Origin
JP
Catalog Category
Communication
Operating Temp.
0 to 55 °C
Humidity
10–90% RH, non-condensing
Model confirmed for inquiry ITNC-EIS01-DRM Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

OMRON ITNC-EIS01-DRM: Stop the Clock on Your Downtime — Ship Today from Xiamen

Every minute your DeviceNet network is dark, the production floor is bleeding money. The ITNC-EIS01-DRM is OMRON’s standalone Ethernet-to-DeviceNet gateway — no PLC CPU required, no backplane slot consumed. When this unit fails, your entire field-bus topology goes silent. We stock it. We ship it. DHL Express from Xiamen, door-to-door in 48–72 hours to most industrial regions worldwide.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Model / SKU ITNC-EIS01-DRM ✅ Ready to Ship
Manufacturer OMRON Corporation 100% Original OEM
Series ITNC (Intelligent Network Controller)
Upper Network Ethernet 100BASE-TX / 10BASE-T
Field Network DeviceNet Master (Group 2 Only)
Max. Slave Nodes 63 nodes
DeviceNet Baud Rates 125 / 250 / 500 kbps (auto or manual)
I/O Capacity 2,048 bits IN / 2,048 bits OUT
Upper Protocols EtherNet/IP, FINS/TCP, FINS/UDP
Power Supply 24 VDC ±10%, 0.5 A max
Operating Temperature 0 to 55 °C
Humidity 10–90% RH, non-condensing
Dimensions (W×H×D) 35 × 90 × 65 mm
Weight Approx. 140 g
Mounting 35 mm DIN Rail
Protection Class IP20
Config Software CX-Integrator Ver. 2.0+
Certifications CE, UL, cUL
Country of Origin Japan

Troubleshooting & Replacement Tips

Common Failure Indicators

Before condemning the ITNC-EIS01-DRM, verify the symptom pattern. The unit typically fails in one of three ways: (1) the MS/NS LEDs both go solid red on power-up — this points to a corrupted internal configuration or a hardware fault on the DeviceNet ASIC; (2) the unit powers up normally but all DeviceNet slaves drop offline simultaneously — suspect the 24 V DeviceNet bus power supply first, not the controller; (3) the Ethernet link LED is active but FINS/TCP connections time out — check for IP address conflicts or a misconfigured subnet mask in the unit’s DIP switch or software settings.

Node Address & Baud Rate DIP Switch Settings

The ITNC-EIS01-DRM uses a rotary switch pair on the front panel to set the DeviceNet MAC ID (node address 0–63). Before swapping the unit, photograph the existing switch positions. The replacement unit must be set to the identical MAC ID as the failed unit — DeviceNet slaves store the master’s node address in their scan list, and a mismatch will prevent polled I/O from establishing. Baud rate is set via a separate DIP switch; confirm it matches the network (most automotive lines run 500 kbps). A baud rate mismatch produces a solid red NS LED with no slave communication.

CX-Integrator Configuration Backup & Restore

If you have a CX-Integrator project file (.cin) from the original unit, restoration is straightforward: connect via Ethernet, go online, and download the scan list. If no backup exists, you must rebuild the scan list manually using the EDS files for each slave node. Allocate 30–90 minutes for this on a large network (40+ nodes). The unit does not store configuration in the DeviceNet network itself — all scan list data lives in the ITNC-EIS01-DRM’s internal flash. A factory-reset replacement unit ships with an empty scan list.

IP Address Assignment

The unit’s Ethernet IP address is set via front-panel rotary switches for the last octet (0–99) combined with a software-configured base address, or fully via software if the rotary is set to 00. On a replacement unit, set the rotary to match the failed unit’s last octet before powering up. Failure to do this will cause the unit to come online at a different IP, making it invisible to the SCADA system until the address is corrected.

Firmware Version Matching

Check the firmware version label on the side of the failed unit before ordering. Units with firmware below V1.3 have a known issue with EtherNet/IP Class 1 connections dropping under high Ethernet load. If your application uses EtherNet/IP I/O connections (not just FINS), confirm the replacement unit carries V1.3 or later. Contact us and we will verify the firmware revision of our stock unit before shipment.

Watchdog & Fail-Safe Output Behavior

By default, when the Ethernet connection to the host controller is lost, the ITNC-EIS01-DRM holds the last commanded DeviceNet output states. In safety-critical applications, this behavior must be reviewed. CX-Integrator allows configuring a watchdog timeout (1–65535 ms) after which outputs can be forced to a defined fail-safe state. Verify this setting is replicated on the replacement unit — a unit with default watchdog behavior in a line that expects fail-safe-off outputs can cause unexpected actuator movement on Ethernet reconnection.

Reliability in Harsh Conditions

The ITNC-EIS01-DRM is built to OMRON’s industrial-grade mechanical and electrical standards. The PCB assembly uses conformal coating on production variants destined for high-humidity environments, providing resistance to condensation ingress that would otherwise corrode solder joints on unprotected boards. The DIN-rail latch mechanism is rated for repeated installation cycles without clip fatigue — relevant in maintenance environments where the unit is removed for inspection quarterly.

Vibration resistance meets IEC 60068-2-6 (10–57 Hz, 0.075 mm amplitude; 57–150 Hz, 9.8 m/s²), making it suitable for installation in panels mounted directly on press frames or conveyor structures where low-frequency mechanical vibration is continuous. Shock resistance per IEC 60068-2-27 (147 m/s², 11 ms half-sine) covers most forklift-impact scenarios in panel rooms adjacent to heavy manufacturing.

The 0–55 °C operating range without forced cooling is a practical advantage in tropical and subtropical factory environments — Southeast Asian automotive plants, Indian textile mills, and Middle Eastern petrochemical facilities routinely see panel interior temperatures of 45–50 °C in summer. The ITNC-EIS01-DRM operates within spec at these temperatures without derating. The 10–90% RH non-condensing humidity rating covers coastal and riverside industrial sites where ambient humidity regularly exceeds 80% RH.

All units in our inventory are stored in climate-controlled warehousing (20–25 °C, 40–60% RH) in ESD-safe packaging. Long-term storage in uncontrolled environments degrades electrolytic capacitors and oxidizes connector contacts — our storage protocol prevents both failure modes, ensuring the unit you receive performs identically to a freshly manufactured part.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct DHL and FedEx gateway access. Standard export documentation (commercial invoice, packing list, certificate of origin) is prepared same day for orders confirmed before 14:00 CST. For urgent orders, we offer a same-day dispatch option for orders confirmed before 11:00 CST.

Typical Transit Times from Xiamen:

  • Southeast Asia (Thailand, Vietnam, Malaysia, Indonesia): 2–3 business days via DHL Express
  • India & South Asia: 3–4 business days via FedEx International Priority
  • Middle East (UAE, Saudi Arabia, Qatar): 3–5 business days via DHL Express
  • Europe (Germany, Italy, Poland, Turkey): 4–6 business days via DHL Express Worldwide
  • North America (USA, Canada, Mexico): 4–5 business days via FedEx International Priority
  • Australia & New Zealand: 3–4 business days via DHL Express

Each shipment includes a real-time tracking number issued within 2 hours of dispatch. For high-value orders, we provide shipment photos (unit serial number visible, packaging sealed) before the courier collects. Export HS code 8537.10 is pre-declared on all shipments to minimize customs clearance delays. For customers in countries with import duty exemptions on industrial automation components, we can provide supporting documentation upon request.

All units are packed in anti-static ESD bags, cushioned with 30 mm polyethylene foam on all six faces, and placed in a double-wall corrugated outer carton. Drop-test packaging standard: 1.2 m free-fall on all faces and corners. The unit arrives at your facility in the same condition it left ours.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier