Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Wiesemann & Theis In Stock OK

W&T 58631 Serial-to-Ethernet Gateway

Request verified availability, condition, replacement risk review, packing options and courier lead time for 58631.

Exact part58631 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandWiesemann & Theis Part Number58631 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 58631

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Wiesemann & Theis
Primary Part Number
58631
Product Type
Industrial Communication Gateway
Product Family
Other series
Manufacturer
Wiesemann & Theis (W&T), Germany
Country of Origin
Germany
Model Function
Serial-to-Ethernet Communication Server
Catalog Category
Communication
Operating Temp.
0 °C to +55 °C
Model confirmed for inquiry 58631 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

W&T 58631 Com-Server Down? Every Minute of Serial Link Loss Costs You Money — We Ship Same Day

Your SCADA host just lost contact with the field bus. The HMI is throwing “No Connection” alarms. The shift supervisor is standing behind you. You already know the 58631 is the single point of failure between your RS-485 multi-drop network and the Ethernet backbone — and right now it’s dead. We’ve been in that control room. We know what the next 90 minutes look like if you don’t have a replacement on the way.

We stock the W&T 58631 Com-Server in Xiamen, China. Verified original. DHL Express to your door in 3–5 business days, worldwide. No MOQ. No waiting on distributor lead times. One unit ships today.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 58631 ✅ Ready to Ship
Manufacturer Wiesemann & Theis (W&T), Germany
Product Family Com-Server
Function Serial-to-Ethernet Communication Server
Serial Interface RS-232 / RS-422 / RS-485 (software-selectable)
Network Interface 10/100 Mbit/s Ethernet, RJ-45
Supported Protocols TCP/IP, UDP, Telnet, DHCP, DNS, HTTP, SNMP
Baud Rate Range 300 – 115,200 bps
Data Bits 7 or 8
Parity None / Even / Odd
Stop Bits 1 or 2
Supply Voltage 24 VDC (±20%)
Power Consumption ≤ 3 W
Operating Temperature 0 °C to +55 °C
Storage Temperature -20 °C to +70 °C
Mounting 35 mm DIN Rail
Certifications CE, RoHS
Country of Origin Germany
Stock Location Xiamen, China ✅ In Stock

Troubleshooting & Replacement Tips

After ten years of field calls, here are the failure modes we see most often with the 58631 — and what to check before you even open the box on the replacement unit.

Fault 1 — No Ethernet Link (LED off or amber): Before condemning the 58631, verify the switch port. A dead PoE port or a misconfigured VLAN has burned more than one engineer. Swap the patch cable and test on a known-good port. If the 58631’s link LED still won’t come up after power cycle, the internal Ethernet PHY is likely gone — common after a nearby lightning strike or surge event on the LAN side.

Fault 2 — Serial RX/TX LED not blinking: Check your RS-485 termination resistor (120 Ω at each end of the bus). A missing or double-terminated bus will cause the 58631 to receive garbage or nothing at all. Also verify the A/B polarity — W&T labels them correctly but field wiring reversals are extremely common. Use a multimeter: A should be positive relative to B during idle state on RS-485.

Fault 3 — TCP connection established but no data passing: This is almost always a baud rate or framing mismatch. The 58631 stores its serial parameters in non-volatile memory. When you swap in a replacement unit, do not assume factory defaults match your application. Open the embedded web server (default IP: DHCP-assigned, or use W&T’s WuTility tool to discover it) and manually re-enter: baud rate, data bits, parity, stop bits, and TCP mode (Raw TCP vs. Telnet). A 5-minute configuration session prevents a 5-hour troubleshooting loop.

Fault 4 — IP address conflict after replacement: The 58631 ships with DHCP enabled by default. If your network uses static addressing, the replacement unit will grab a random DHCP lease and your SCADA driver will keep polling the old IP. Assign the static IP immediately after first boot via the web interface before connecting to the production network segment.

Fault 5 — Intermittent disconnects under load: Check the 24 VDC supply rail. The 58631 draws ≤3 W but a sagging PSU shared with contactors or solenoids can cause brownout resets. Measure the supply under load — anything below 19.2 VDC (24 V × 80%) is suspect. Also inspect the DIN rail ground connection; a floating ground on the RS-485 side will cause burst errors that look like firmware bugs.

Replacement Checklist (laminate this and keep it in the cabinet):

  • Power down the failed unit; label and photograph all wiring before disconnecting
  • Note the existing IP address, subnet mask, gateway from the old unit’s web page (if still accessible)
  • Mount replacement on DIN rail; reconnect power and Ethernet first — do not connect serial yet
  • Access web interface via WuTility or DHCP lease; configure IP, serial parameters, TCP mode
  • Connect serial wiring; verify A/B polarity and termination
  • Power cycle the field device on the serial bus; confirm RX/TX LEDs blink
  • Restore SCADA connection; acknowledge alarms; log the swap in the maintenance record

Reliability in Harsh Conditions

The W&T 58631 is not a consumer-grade device dressed up in industrial packaging. It is designed from the ground up for continuous, unattended operation in environments that would kill a standard network device within weeks.

The compact plastic enclosure is engineered for DIN rail installation inside sealed control cabinets where temperatures routinely cycle between cold morning startups and afternoon heat buildup from adjacent drives and transformers. The 0–55 °C operating range is a tested specification, not a marketing claim — W&T validates this across the full product line in their German manufacturing facility.

Vibration is a constant in any plant with rotating machinery, compressors, or heavy presses. The 58631’s DIN rail clip and internal PCB mounting are designed to withstand the continuous low-frequency vibration profiles common in these environments. Solder joint fatigue — the silent killer of cheaper gateways — is addressed through W&T’s manufacturing process controls.

Humidity and condensation are managed through the sealed enclosure design. While the 58631 is not rated IP65, its housing prevents the ingress of airborne contaminants and moisture that accumulates in coastal or chemical plant environments. For installations in particularly aggressive atmospheres, a conformal-coated PCB variant is available — contact us for details.

The 24 VDC power input with ±20% tolerance (19.2–28.8 VDC) means the unit keeps running through the supply fluctuations that are normal in any plant with large motor loads switching on and off. The ≤3 W consumption also means it generates minimal heat of its own, contributing to long-term component reliability.

In our experience sourcing and testing these units, the 58631 is one of the most robust serial gateways in its class. Units pulled from decommissioned installations after 10+ years of service routinely pass full functional testing. That is the benchmark we hold our stock to before it ships to you.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province, China — one of the most logistics-efficient export hubs in Asia, with direct access to DHL, FedEx, and UPS international express networks.

Standard Express Timeline (DHL/FedEx):

  • Southeast Asia (SG, MY, TH, VN, ID): 2–3 business days
  • East Asia (JP, KR, TW, HK): 2–3 business days
  • Europe (DE, NL, FR, UK, IT, PL): 4–6 business days
  • North America (US, CA, MX): 4–5 business days
  • Middle East (AE, SA, QA, KW): 3–5 business days
  • Australia & New Zealand: 4–6 business days
  • South America (BR, CL, AR, CO): 6–9 business days
  • Africa: 6–10 business days

Shipment Process: Orders confirmed before 14:00 CST are processed for same-day dispatch. Each unit is individually packed with anti-static protection, bubble wrap, and a double-wall export carton rated for international air freight handling. A commercial invoice, packing list, and HS code declaration (8517.62) are included with every shipment for customs clearance. We can provide a proforma invoice for your import documentation on request.

Tracking numbers are issued within 2 hours of dispatch and sent directly to your email. For time-critical shipments, we can arrange Saturday pickup with DHL at no additional lead time. If your plant is in a remote location or a country with complex import regulations, contact us before ordering — we have experience shipping to over 60 countries and can advise on the fastest compliant routing.

For orders requiring air freight on a pallet (multiple units or accompanying spare parts), we work with a licensed freight forwarder in Xiamen with direct relationships with major airlines. Door-to-door air freight quotes are available within 4 hours of inquiry.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.