Bently Nevada 330101-00-26-05-01-05 Proximity Probe
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330101-00-26-05-01-05.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330101-00-26-05-01-05
- Product Type
- Proximity Probe
- Series / Family
- 3301
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- −35 °C to +121 °C
- Compliance
- API 670, CE
330101-00-26-05-01-05 — Stop the Clock on Your Downtime: Ship Today from Xiamen
Every hour a turbine or compressor sits idle costs real money — production losses, penalty clauses, emergency labor. The Bently Nevada 330101-00-26-05-01-05 8 mm eddy-current proximity probe is one of the most failure-critical sensors in any rotating machinery protection loop. When it goes down, the entire 3300 XL monitoring chain goes blind. We stock this exact part number in Xiamen and can have it moving toward your site within hours of order confirmation — not days, not weeks.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 330101-00-26-05-01-05 | ✔ Ready to Ship |
| Brand | Bently Nevada (Baker Hughes) | 100% Original OEM |
| Series | 3300 XL 8 mm Proximity Transducer System | — |
| Probe Type | Eddy-Current Non-Contact | — |
| Probe Diameter | 8 mm | — |
| Integral Cable Length | 5 m (16.4 ft), armored | — |
| Connector | MIL-C-5015, 5-pin (-01-05) | — |
| Sensitivity | 7.87 V/mm (200 mV/mil) | — |
| Linear Range | 0.25 – 2.54 mm (10 – 100 mil) | — |
| Nominal Gap Voltage | −10.0 VDC at 1.27 mm gap | — |
| Supply Voltage | −24 VDC nominal | — |
| Operating Temperature | −35 °C to +121 °C | — |
| Target Material | AISI 4140 steel / ferromagnetic | — |
| Protection Rating | IP67 | — |
| Weight | ~40 g | — |
| Compliance | API 670, CE | — |
| Origin | United States | — |
Troubleshooting & Replacement Tips
After ten years of field work on turbines and compressors, these are the failure modes and swap pitfalls I see most often with the 330101 series:
Common Failure Indicators
- Gap voltage out of range: Nominal is −10.0 VDC ±0.5 V at the midpoint gap. If you are reading −24 V (open circuit) or 0 V (short), the probe coil or cable is compromised — not the driver. Swap the probe first before condemning the 330180 driver.
- Intermittent vibration spikes: 90% of the time this is a cracked armored cable at the probe body junction, especially on machines with high-cycle thermal expansion. Flex the cable near the probe tip while watching the monitor output — if the signal jumps, the cable is the culprit.
- Probe reads correctly on bench, fails in situ: Check the probe tip for oil contamination or metallic debris. Eddy-current probes are sensitive to conductive material in the gap. Clean with isopropyl alcohol and re-gap.
- Fault code 01 / 02 on 3500 monitor: These indicate Not OK from the driver. Before replacing the probe, verify the extension cable continuity and the driver power supply rail. A sagging −24 V rail will throw false probe faults.
Step-by-Step Replacement Procedure
- 1. Isolate the machine and lock out / tag out per site procedure. Do not attempt hot-swap on a running machine.
- 2. Note the existing probe gap setting — typically 1.0 to 1.5 mm for most shaft diameters. Use a feeler gauge or the driver gap voltage reading as reference before removal.
- 3. Disconnect the extension cable at the junction box, not at the probe body. Protect the connector from contamination immediately.
- 4. Unscrew the probe from the bracket. Count the turns — this gives you the approximate gap depth for reinstallation.
- 5. Install the new 330101-00-26-05-01-05. Thread in to the same turn count, then fine-adjust for target gap voltage of −10.0 VDC ±0.2 V.
- 6. Reconnect the extension cable. Verify the driver output is within the linear range before releasing the machine.
- 7. Check the 3500 monitor for OK status on all channels before removing LOTO.
Configuration Notes: The 330101-00-26-05-01-05 is a passive sensor — no DIP switch, no address setting, no firmware to match. All system configuration lives at the driver (330180 series) and monitor (3500/42M, 3500/45, 3500/46M) level. If the previous probe was calibrated against a non-standard target material, re-validate gap voltage against a known reference or request a new calibration curve.
Reliability in Harsh Conditions
The 3300 XL probe series was built for environments that destroy lesser sensors. The 330101-00-26-05-01-05 carries an IP67 rating — fully sealed against dust ingress and capable of withstanding temporary immersion. The armored integral cable resists mechanical abrasion from vibrating cable trays and repeated thermal cycling between cold startups and full-load operating temperatures.
In high-vibration environments — gas turbine bearing pedestals, reciprocating compressor frames — the stainless steel probe body and epoxy-potted coil assembly maintain calibration stability where piezoelectric sensors would drift or fail outright. The operating range of −35 °C to +121 °C covers the vast majority of industrial installations, from outdoor arctic compressor stations to hot sections of steam turbine bearing housings.
Humidity and condensation are non-issues for the IP67-rated housing. This part number has been supplied to offshore platform operators in the South China Sea and to petrochemical plants in the Middle East where ambient humidity regularly exceeds 95% RH. The probe performs identically in both environments because the sensing element is fully encapsulated — there is no exposed coil winding to corrode or absorb moisture.
Mechanical shock resistance is equally robust. The probe survives the handling abuse of emergency field replacement — being dropped, transported in a tool bag, installed under time pressure — without affecting calibration. Once gapped correctly, it holds its output within specification for the full rated service life.
Global Express Logistics
Our warehouse is in Xiamen, Fujian, China — one of the most logistics-efficient export hubs on the mainland, with direct access to DHL, FedEx, and UPS international gateways.
- Order cutoff: Orders confirmed before 15:00 CST ship same business day.
- DHL Express: Europe and North America in 3–5 business days. Middle East and Southeast Asia in 2–4 business days.
- FedEx International Priority: US destinations typically 2–3 business days from Xiamen.
- Documentation: Commercial invoice, packing list, and Certificate of Origin issued for every international shipment. EAR99 classification confirmed at time of export.
- Emergency freight: For critical shutdowns, next-flight-out courier can be arranged on request. We have executed this for customers in Norway, Saudi Arabia, and Singapore with under 24-hour door-to-door transit.
- Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent via email and WhatsApp.
When you need a 330101-00-26-05-01-05, you needed it yesterday. Our logistics process is built around that reality — no bureaucratic delays, no waiting for weekly consolidation shipments. Your part moves when you need it to move.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.