Woodward In Stock OK

Woodward 80026-518-01-R Power Supply Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 80026-518-01-R.

Exact part80026-518-01-R RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandWoodward Part Number80026-518-01-R ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 80026-518-01-R

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Woodward
Primary Part Number
80026-518-01-R
Product Type
Power Supply Module
Product Family
Other series
Manufacturer
Woodward
Country of Origin
US
Catalog Category
Power Supplies
Humidity
5–95% RH, non-condensing
Compliance
CE, RoHS (original OEM certification scope)
Model confirmed for inquiry 80026-518-01-R Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Woodward 80026-518-01-R Power Supply Module — Stop the Clock on Your Downtime

Your turbine is tripped. The DCS rack is dark. Maintenance is standing by and every minute offline is burning through your production budget. The Woodward 80026-518-01-R power supply module is the single point of failure you cannot afford to wait weeks for. We stock it. We ship it today. From Xiamen to your site via DHL or FedEx Express — typically 2–5 business days to most global destinations.

This is not a catalog listing. This is a live inventory position. If you are reading this page, the unit is available. Contact us before you close this tab.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Detail
Part Number 80026-518-01-R
Manufacturer Woodward
Module Function Control System Power Supply / Power Rail Module
Suffix “-R” Factory-Refurbished — fully tested to OEM functional spec
Output Regulated DC bus power for Woodward control backplane
Form Factor Rack-mount / DIN-rail compatible, direct backplane insertion
Connector Multi-pin backplane edge connector (OEM pinout retained)
Weight 600 g (approx.)
Operating Temp 0 °C to +60 °C (standard industrial panel range)
Humidity 5–95% RH, non-condensing
Compliance CE, RoHS (original OEM certification scope)
Country of Origin United States
Stock Status ✅ Ready to Ship — Xiamen Warehouse
Lead Time Same-day dispatch on orders confirmed before 15:00 CST

Troubleshooting & Replacement Tips

After ten years of field calls on Woodward-based turbine and DCS panels, these are the failure patterns and swap pitfalls that actually matter:

Common Failure Signatures for 80026-518-01-R:

  • Intermittent rack brownout / CPU reset loops — The PSU output capacitors degrade over time, causing voltage sag under transient load. If your controller is rebooting without a clear software fault, pull the PSU first before chasing I/O cards.
  • Fault LED solid ON, no output voltage — Internal over-current protection has latched. Disconnect all backplane loads, cycle power. If the fault clears with no load but returns under load, the PSU is failing — not the downstream cards.
  • Thermal shutdown in summer / high-ambient environments — Inadequate panel ventilation causes the internal thermal cutoff to trip. Check that panel inlet filters are clean and that the PSU’s ventilation slots are not obstructed by cable bundles.
  • Noisy 24 VDC bus causing analog I/O drift — A failing PSU can introduce ripple onto the DC bus. If your analog inputs are reading erratically and calibration checks out, measure bus ripple with an oscilloscope before replacing I/O cards.

Replacement Procedure — Key Steps:

  1. Confirm upstream AC/DC input is isolated and locked out before extraction. The backplane remains energized from redundant rails if a second PSU is fitted — verify which slot you are pulling.
  2. The 80026-518-01-R uses a direct backplane connector — no field wiring terminations. Extraction is tool-free via the front-panel ejector levers. Do not force the module; misaligned ejection can damage backplane pins.
  3. Before inserting the replacement, inspect the backplane connector for bent pins or corrosion. A failed PSU that shorted internally can leave carbon deposits on the backplane socket — clean with isopropyl alcohol and a non-conductive brush.
  4. After insertion, restore power and observe the PSU status LED sequence. A healthy unit will show a brief amber flash during self-test, then transition to solid green within 3–5 seconds. If the fault LED latches immediately, the backplane may have a downstream short — do not continue troubleshooting with the new PSU inserted.
  5. No firmware flashing or address configuration is required for this PSU module. It is not a programmable node — it is a pure power conditioning unit. No DIP switch settings apply.
  6. If your system runs dual-redundant PSUs, verify that the load-sharing balance is within spec after replacement. An imbalanced pair will cause one unit to run hot and fail prematurely.

Reliability in Harsh Conditions

Woodward designs its control system hardware for the environments where failure is not an option. The 80026-518-01-R is built to operate continuously in conditions that would destroy consumer or light-industrial electronics:

  • Vibration — The module’s PCB assembly uses conformal coating and through-hole anchoring on high-mass components to resist the continuous vibration present in turbine generator halls and compressor stations. Solder joint fatigue — the silent killer of board-level electronics in rotating machinery environments — is mitigated by design.
  • Thermal Cycling — Industrial panels experience wide temperature swings between cold startups and full-load operation. The PSU’s thermal design accommodates repeated cycling without delamination of PCB layers or connector contact degradation.
  • Humidity and Condensation — Conformal coating on the PCB provides a barrier against moisture ingress in coastal, offshore, and tropical installations. Units destined for high-humidity sites should be stored in sealed anti-static packaging until installation.
  • Electrical Noise — The module includes internal EMI filtering on both the input and output rails, isolating the sensitive control backplane from the high-frequency switching noise common in variable-frequency drive (VFD) environments and large motor starter panels.
  • Refurbishment Standard — Every “-R” suffix unit we ship has been through a full functional test cycle: power-on verification, output regulation check under load, burn-in run, and visual inspection of all connectors and PCB surfaces. Units that do not pass are not shipped — they are parted out or scrapped.

Global Express Logistics

Our Xiamen warehouse is positioned specifically for fast international dispatch. Here is exactly how your order moves:

  • Order Confirmation → Same-Day Pick & Pack — Orders confirmed before 15:00 CST are picked, ESD-packed, and handed to the carrier the same business day. Orders after cutoff ship the following morning.
  • Carrier Options — DHL Express Worldwide and FedEx International Priority are our primary carriers. Both provide door-to-door tracking and customs clearance support. We select the fastest available routing for your destination at time of booking.
  • Transit Times (typical) — Southeast Asia: 1–2 days. Middle East, India: 2–3 days. Europe: 3–4 days. Americas: 3–5 days. Remote or island destinations may add 1–2 days.
  • Export Documentation — Commercial invoice, packing list, and certificate of conformance are prepared for every shipment. For customers requiring a specific HS code declaration or country-of-origin certificate, advise us at order time.
  • Customs & Duties — We declare accurate commercial values. DAP (Delivered At Place) is our standard Incoterm — import duties and local taxes are the buyer’s responsibility. We can advise on HS code classification to help you estimate landed cost.
  • Packaging — The module ships in an anti-static bag, surrounded by high-density foam insert, inside a double-wall corrugated carton. It arrives ready to install, not ready to be inspected for transit damage.

Contact Information

Ready to order or need a quote? Reach us directly — no ticketing system, no chatbot queue.

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.