Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 2XV9450-1AR23 E10433-E9600-H110 SICLOCK TM Master Clock

Request verified availability, condition, replacement risk review, packing options and courier lead time for 2XV9450-1AR23.

Exact part2XV9450-1AR23 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number2XV9450-1AR23 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 2XV9450-1AR23

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
2XV9450-1AR23
Product Type
Industrial Time Synchronization Module
Product Family
Other series
Manufacturer
Siemens AG
Country of Origin
DE
Model Function
Plant Central Master Clock — Stratum-1 NTP Source
Catalog Category
Industrial Automation Spares
Operating Temp.
0 °C to +55 °C continuous
Compliance
CE, UL, IEC 60068, EN 61000 EMC
Model confirmed for inquiry 2XV9450-1AR23 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 2XV9450-1AR23 E10433-E9600-H110 — Stop the Clock on Your Downtime

Every minute your plant runs without a synchronized time reference, you’re flying blind. Fault logs diverge. Protection relays timestamp events with garbage data. Your maintenance team wastes hours correlating incidents that should take minutes. The Siemens 2XV9450-1AR23 E10433-E9600-H110 SICLOCK TM Plant Central Master Clock is the authoritative time source your entire automation network depends on — and when it fails, nothing else works right. We stock it. We ship it fast. From Xiamen to your site, DHL or FedEx, door to door.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Manufacturer Siemens AG
Part Number 2XV9450-1AR23
Order Reference E10433-E9600-H110
Series SICLOCK TM (Time Management)
Function Plant Central Master Clock — Stratum-1 NTP Source
Supply Voltage 90–230 V AC/DC wide-range input
Time Reference Input GPS antenna (primary) / DCF77 radio (secondary)
Output Protocols NTP/SNTP (Ethernet RJ45), IRIG-B, RS-232/RS-485 serial telegrams
Synchronization Accuracy ≤ 1 µs (GPS-locked, UTC-traceable)
Holdover Drift ≤ 1 ms/day (internal TCXO oscillator)
Operating Temperature 0 °C to +55 °C continuous
Storage Temperature −25 °C to +70 °C
Mounting 19-inch rack / DIN rail compatible
Protection Rating IP20
Weight 3,060 g
Compliance CE, UL, IEC 60068, EN 61000 EMC
Origin Germany
Stock Status ✔ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Replacing the 2XV9450-1AR23 is not a plug-and-play swap if you skip the configuration steps. Here’s what actually matters on-site:

1. GPS Antenna Continuity Check Before You Pull the Old Unit
The most common reason a replacement SICLOCK TM fails to lock is a degraded coaxial antenna cable — not the clock itself. Before you rack the new unit, measure antenna cable impedance (50 Ω) and verify the antenna has clear sky view. A failed GPS lock will show as a solid red LED on the front panel with no PPS output. Don’t assume the new unit is faulty until you’ve ruled out the antenna path.

2. NTP Client Re-pointing
After swapping the master clock, every NTP client on the network — SIMATIC S7 CPUs, SCALANCE switches, HMI panels, historian servers — must be re-pointed to the new unit’s IP address if it changed. Use the SICLOCK TM web interface (default: 192.168.1.1) to assign a static IP matching your plant network scheme before connecting to the LAN. Failure to do this results in clients falling back to their internal clocks within 1,000 seconds, causing timestamp drift across the entire DCS.

3. IRIG-B Output Wiring Polarity
The IRIG-B output on the 2XV9450-1AR23 is differential RS-422. Reversed polarity on the terminal block will produce a signal that protection relays accept but decode incorrectly — your relay event logs will show timestamps offset by exactly 1 second, which is a classic sign of IRIG-B polarity reversal. Verify A(+) and B(−) against the terminal labeling on the rear panel before energizing.

4. DCF77 Fallback Configuration
If your site uses DCF77 as a backup reference, confirm the DCF77 receiver module is seated correctly in its slot and the antenna cable is routed away from VFD cabinets and high-current busbars. DCF77 operates at 77.5 kHz and is extremely susceptible to conducted EMI from nearby drives. A DCF77 receiver that never locks is almost always an antenna placement issue, not a hardware fault.

5. Firmware Version Matching
If you are replacing a unit that was running a specific SICLOCK TM firmware version to maintain compatibility with older SINAUT or SICAM subsystems, note the firmware version from the old unit’s web interface before decommissioning it. The replacement unit may ship with a newer firmware. Downgrading is possible via the SICLOCK TM configuration tool — contact us and we can advise on the correct firmware package for your installed base.

Common Fault Codes:

  • GPS UNLOCK (red LED, no PPS): Antenna cable fault, obstructed sky view, or failed GPS receiver module. Check antenna first.
  • NTP STRATUM 16: Unit has lost its reference and is advertising itself as unsynchronized. Clients will reject it. Restore GPS or DCF77 lock immediately.
  • IRIG-B NO SIGNAL: Output channel disabled in configuration, or wiring fault on terminal block. Verify output enable setting in web interface.
  • POWER FAIL alarm: Wide-range PSU accepts 90–230 V AC/DC — verify input voltage is within range and check fuse on rear panel (typically 2 A slow-blow).

Reliability in Harsh Conditions

The SICLOCK TM 2XV9450-1AR23 was not designed for a server room. It was designed for substations, control rooms adjacent to high-voltage switchgear, and process plant environments where temperature swings, conducted EMI, and vibration are daily realities.

The unit’s PCBs are conformal-coated to resist condensation and airborne contaminants — a non-negotiable requirement in coastal chemical plants and offshore platforms where humidity regularly exceeds 90% RH. The wide-range power supply (90–230 V AC/DC) means the unit continues operating through voltage sags and brownouts that would crash a standard power supply, and it accepts DC input directly from a 110 V or 125 V substation battery bus without an inverter.

Vibration tolerance meets IEC 60068-2-6 (sinusoidal) and IEC 60068-2-27 (shock) test profiles — the same standards applied to protection relays and industrial PLCs. In practice, this means the unit survives the mechanical shock of nearby circuit breaker operations and the continuous vibration of pump and compressor rooms without connector fatigue or PCB cracking.

EMC compliance to EN 61000-4 series (EFT, surge, conducted immunity) ensures the unit does not lose GPS lock or reset when high-energy transients propagate through the plant power system — a failure mode that plagues cheaper time servers installed in industrial environments.

Every unit we ship from our Xiamen warehouse is bench-tested: powered at rated voltage, GPS lock acquisition verified, NTP output confirmed with a reference client, and IRIG-B signal integrity checked with an oscilloscope. We do not ship untested stock.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international express networks. For urgent replacement orders, here is the realistic timeline:

  • Order confirmed before 14:00 CST: Same-day dispatch. Tracking number issued within 2 hours of pickup.
  • DHL Express Worldwide: Europe 2–3 business days, Southeast Asia 1–2 business days, Middle East 2–4 business days, Americas 3–5 business days.
  • FedEx International Priority: Comparable transit times; preferred for shipments to the US and Canada where FedEx ground network provides final-mile reliability.
  • Export Documentation: Commercial invoice, packing list, and certificate of origin issued with every shipment. For customers requiring ATA Carnet or specific customs declarations, advise at time of order.
  • Packaging: Anti-static foam insert, double-wall carton, desiccant pack. The 2XV9450-1AR23 weighs 3,060 g — packaged gross weight approximately 4.5 kg. No special dangerous goods classification required.
  • Customs HS Code: 9025.80 (instruments for measuring or checking electrical quantities) — standard industrial electronics classification, low risk of customs delay in most jurisdictions.

If your plant is facing an active shutdown and you need the fastest possible delivery, contact us directly on WhatsApp before placing the order. We will confirm stock, arrange priority pick, and coordinate with the courier for the earliest available flight.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.