Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
GE Vernova In Stock OK

GE IC695PNC001LT PROFINET Controller Module – PACSystems RX3i

Request verified availability, condition, replacement risk review, packing options and courier lead time for IC695PNC001LT.

Exact partIC695PNC001LT RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandGE Vernova Part NumberIC695PNC001LT ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ IC695PNC001LT

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
GE Vernova
Primary Part Number
IC695PNC001LT
Product Type
PROFINET Controller Module
Series / Family
PACSystems
Country of Origin
US
Catalog Category
Communication
Operating Temp.
0 °C to +60 °C
Warranty
12 months from date of shipment
Model confirmed for inquiry IC695PNC001LT Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

GE IC695PNC001LT – PROFINET IO Controller for PACSystems RX3i Backplane Architecture

The IC695PNC001LT is GE Vernova’s dedicated PROFINET IO Controller module engineered for the PACSystems RX3i universal backplane platform. Conforming to IEC 61158 and IEC 61784-2, this single-slot module assumes the role of PROFINET IO Controller (Class A and Class B), managing cyclic process data exchange between the RX3i CPU and up to 128 distributed PROFINET IO devices across a single Ethernet segment or multi-segment topology. Its dual RJ45 ports with integrated switch fabric allow linear and ring wiring without external managed switches, a design decision that directly reduces panel hardware count and eliminates inter-switch latency from the deterministic communication path.

Within the RX3i backplane, the IC695PNC001LT communicates with the host CPU — such as the IC695CPU320 or IC695CPU310 — via the high-speed parallel backplane bus. Process image data is transferred through a shared-memory DMA mechanism, meaning the PROFINET scan cycle does not consume CPU ladder scan time in the same way a serial fieldbus module would. This architectural separation allows the CPU to maintain its deterministic scan rate independent of PROFINET network load fluctuations, a critical property in multi-axis motion coordination and high-throughput discrete manufacturing lines.

The module supports RT Class 1 (UDP/IP encapsulated) and RT Class 2 (VLAN-tagged, prioritized) communication modes, with a configurable send clock ranging from 1 ms to 512 ms. This range accommodates both high-speed discrete IO applications — where 1 ms update rates are required for servo drive torque feedback — and slower process IO applications such as valve positioners and flow transmitters, where 32 ms or 64 ms cycles are operationally sufficient and reduce network bandwidth consumption. The IC695PNC001LT does not support PROFINET IRT (Isochronous Real-Time, RT Class 3); applications requiring sub-millisecond jitter-bounded motion synchronization should evaluate IRT-capable controller alternatives.

Configuration and device commissioning are performed entirely within GE Proficy Machine Edition. GSDML v2.x device description files for any PROFINET-compliant IO device — including third-party drives, remote IO heads, and safety modules — are imported directly into the project, after which IO slot mapping, alarm routing, and substitution value behavior are configured graphically. No separate programming connection to the IC695PNC001LT is required; all parameterization is downloaded through the RX3i CPU’s Ethernet port and propagated to the controller module via the backplane.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number IC695PNC001LT
Platform PACSystems RX3i (Universal Backplane)
Module Function PROFINET IO Controller, Class A & B
Network Standard PROFINET IO v2.3 / IEC 61158 / IEC 61784-2
Physical Ports 2 × RJ45, 10/100 Mbps, Auto-MDI/MDIX, integrated 2-port switch
Max IO Devices 128 PROFINET IO devices per controller instance
Process Data Capacity 4096 bytes input / 4096 bytes output
Send Clock Range 1 ms – 512 ms (configurable per device)
RT Class Support RT Class 1 (UDP/IP), RT Class 2 (VLAN-tagged); IRT not supported
Backplane Power Draw 1.1 A @ 3.3 VDC (from RX3i backplane rail)
Operating Temperature 0 °C to +60 °C
Storage Temperature –40 °C to +85 °C
Relative Humidity 5% – 95% RH, non-condensing
Vibration Resistance IEC 60068-2-6
Mechanical Shock IEC 60068-2-27
EMC Compliance EN 61000-4-2 (ESD), EN 61000-4-4 (EFT/Burst), EN 61000-4-5 (Surge)
Certifications CE, UL, cUL, RoHS (LT suffix = lead-free)
Firmware Upgrade Field-upgradeable via Proficy Machine Edition over backplane
Form Factor Single-slot RX3i universal module
Approximate Weight 120 g
Warranty 12 months from date of shipment

Hardware Logical Analysis

The IC695PNC001LT’s dual-port integrated switch fabric is implemented at the silicon level, not through an external managed switch chip connected via MII. This means frame forwarding between Port 1 and Port 2 occurs at wire speed with a deterministic cut-through latency of approximately 1–2 µs, well below the jitter budget of RT Class 2 communication. The switch fabric supports IEEE 802.1Q VLAN tagging and IEEE 802.1p priority queuing, which the PROFINET stack uses to assign RT frames to the highest-priority queue (CoS 6), ensuring RT traffic is never queued behind best-effort TCP/IP traffic on a shared network segment.

From an EMC standpoint, the module’s PCB layout follows GE’s standard RX3i design rules: the PROFINET PHY transceivers are isolated from the backplane logic plane by a dedicated ground plane split, and the RJ45 connectors incorporate integrated magnetics with common-mode choke filtering rated to suppress conducted interference up to 30 MHz. This design satisfies EN 61000-4-4 (EFT/Burst, 2 kV) and EN 61000-4-5 (Surge, 1 kV line-to-earth) without requiring external surge protection devices on the Ethernet cable — a meaningful cost and space saving in panel design.

The module’s PROFINET stack implements the Alarm CR (Communication Relationship) mechanism defined in IEC 61158-6-10. When an IO device reports a channel diagnostic — for example, a short-circuit on a digital output module — the alarm is transmitted via the Alarm CR to the IC695PNC001LT, which maps it directly into the RX3i CPU’s fault table without requiring any user-written ladder logic. This native alarm propagation reduces the diagnostic ladder code burden by eliminating the need for custom status-word parsing routines that are common in older fieldbus implementations.

The “LT” suffix designates the RoHS-compliant, lead-free solder variant of the IC695PNC001. Electrically and functionally, the two variants are identical; the LT version is mandatory for CE-marked installations within the European Union under the RoHS Directive 2011/65/EU and its 2015 amendment. Both variants share the same firmware image and GSDML compatibility matrix.

System Integration Benefits

  • Backplane DMA data transfer: Process image exchange between the PROFINET controller and the RX3i CPU uses direct memory access across the backplane bus, decoupling PROFINET cycle time from CPU ladder scan time and preventing network jitter from propagating into the PLC scan.
  • 128-device scalability without gateway hardware: A single IC695PNC001LT manages up to 128 IO devices natively, eliminating the cost, latency, and maintenance overhead of intermediate PROFINET-to-fieldbus gateway modules in large distributed IO architectures.
  • Topology flexibility via integrated switch: The dual-port switch supports star, line, and ring (MRP) topologies. MRP ring recovery time is ≤ 200 ms per PROFINET specification, providing network-level redundancy without a managed switch investment.
  • GSDML-based zero-configuration device onboarding: Any PROFINET IO device with a valid GSDML v2.x file can be integrated into the project without manual register mapping. Proficy Machine Edition auto-populates IO slot addresses from the GSDML, reducing commissioning time per device to under 5 minutes.
  • Native fault table integration: PROFINET channel diagnostics and module alarms are routed directly to the RX3i CPU fault table, providing a single-pane diagnostic view without custom status-word ladder logic.
  • Configurable send clock per device: Each IO device’s update rate is independently configurable from 1 ms to 512 ms, allowing bandwidth optimization — high-speed devices receive fast cycles while slow process devices consume minimal network bandwidth.
  • Field firmware upgrades: Firmware updates are applied through Proficy Machine Edition via the CPU backplane connection, requiring no physical access to the module and no specialized programming hardware beyond the standard engineering workstation.
  • Third-party IO device interoperability: The module’s conformance to PROFINET IO v2.3 Class B ensures interoperability with IO devices from Siemens, Phoenix Contact, Beckhoff, Wago, Turck, and other PROFINET-certified vendors, protecting the investment in existing field device infrastructure during control system migrations.

Quality Assurance & Global Logistics

Every IC695PNC001LT unit supplied through siemensplc.com is sourced as genuine GE Vernova (formerly GE Automation & Controls) manufactured hardware. Each unit undergoes a documented pre-shipment inspection protocol: power-on functional verification, PROFINET link negotiation test on both RJ45 ports, firmware version recording, and visual inspection for connector integrity and PCB condition. Serial number, date code, and firmware revision are documented per shipment and provided to the buyer as part of the delivery package.

Units are packaged in IEC 61340-5-1 compliant ESD-safe anti-static bags, placed in foam-lined export cartons with humidity indicator cards. This packaging standard is maintained regardless of shipment quantity, from single-unit emergency replacements to multi-unit project orders.

Logistics operations are based in Xiamen, China, with established accounts on DHL Express, FedEx International Priority, and UPS Worldwide Express. Standard transit time to major industrial hubs — Frankfurt, Chicago, Singapore, Dubai — is 3 to 5 business days. For time-critical plant shutdowns or emergency replacements, same-day dispatch is available for orders confirmed before 14:00 CST. Full AWB tracking is provided at time of dispatch, and export documentation (commercial invoice, packing list, certificate of origin) is prepared to comply with destination country customs requirements. All units carry a 12-month operational warranty from the date of shipment, with DOA replacement processed within 5 business days of confirmed fault report.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.