Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Yokogawa In Stock OK

YOKOGAWA NFAI141-S00 Analog Input Module – STARDOM FCN/FCJ

Request verified availability, condition, replacement risk review, packing options and courier lead time for NFAI141-S00.

Exact partNFAI141-S00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandYokogawa Part NumberNFAI141-S00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ NFAI141-S00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Yokogawa
Primary Part Number
NFAI141-S00
Product Type
Analog Input Module
Series / Family
STARDOM
Manufacturer
YOKOGAWA Electric Corporation
Country of Origin
JP
Catalog Category
I/O Modules
Operating Temp.
0°C to +55°C
Warranty
12 months from date of shipment
Model confirmed for inquiry NFAI141-S00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

YOKOGAWA NFAI141-S00: 4-Channel Analog Input Module for STARDOM FCN/FCJ Autonomous Controllers

The NFAI141-S00 is a dedicated analog input module engineered for YOKOGAWA’s STARDOM FCN and FCJ autonomous controller platforms. Within a distributed control architecture, this module occupies the signal acquisition layer — converting field-level 4–20 mA current loops and 1–5 V voltage signals into 16-bit digital values that the FCN/FCJ CPU processes in real time. Its role is not passive conditioning; it is the deterministic front-end that defines the accuracy floor of every closed-loop control function running on the host controller. Without a correctly specified AI module, upstream transmitter precision is irrelevant — the ADC resolution and isolation architecture of the input card set the ceiling for the entire measurement chain.

Deployed across oil and gas wellhead RTUs, power generation governor feedback loops, chemical plant DCS hybrid nodes, and water treatment remote pump stations, the NFAI141-S00 has accumulated a field record in environments where signal integrity failures translate directly into process upsets or safety events. Its 4-channel density, dual-mode input acceptance, and full galvanic isolation make it a standard specification item for engineers building STARDOM-based control nodes where panel space, wiring cost, and measurement reliability are simultaneously constrained.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Model Number NFAI141-S00
Manufacturer YOKOGAWA Electric Corporation
Compatible Platform STARDOM FCN / FCJ Autonomous Controllers
Module Function Analog Input (AI) — Current & Voltage
Number of Channels 4 (independent)
Input Signal — Current 4–20 mA DC
Input Signal — Voltage 1–5 V DC
A/D Resolution 16-bit
Measurement Accuracy ±0.1% of full scale at 25°C
Channel Isolation Galvanic isolation, channel-to-channel and channel-to-backplane bus
Maximum Loop Resistance 600 Ω (4–20 mA mode)
Operating Temperature 0°C to +55°C
Storage Temperature −25°C to +70°C
Relative Humidity 5% to 95% RH (non-condensing)
Power Supply Via STARDOM FCN/FCJ backplane bus (no external supply required)
Mounting Interface FCN/FCJ base unit I/O slot (hot-swap capable)
Approx. Weight 250 g
Certifications CE (EMC + LVD), UL, cUL, RoHS, ATEX Zone 2 (with certified barriers)
Country of Origin Japan
Warranty 12 months from date of shipment

Hardware Logical Analysis

The NFAI141-S00’s internal architecture is structured around three functional stages: front-end signal conditioning, isolated A/D conversion, and backplane bus interfacing.

Front-End Signal Conditioning: Each of the four input channels incorporates a dedicated input impedance network that presents a defined load to the field transmitter — approximately 250 Ω in current mode, ensuring the 4–20 mA loop operates within the transmitter’s compliance voltage budget even at maximum cable resistance. In voltage mode (1–5 V), the input impedance is raised to minimize loading on the source. A transient voltage suppression (TVS) network at each terminal block protects the ADC front-end against IEC 61000-4-5 surge events (±1 kV line-to-earth, ±0.5 kV line-to-line) without requiring external surge arrestors in standard installations.

Galvanic Isolation Architecture: The isolation barrier between the field-side circuitry and the backplane-side digital logic is implemented using transformer-coupled DC/DC converters for power and optocoupler or capacitive coupling for signal paths. This architecture achieves channel-to-channel isolation voltages typically rated at 500 V DC working voltage, eliminating ground-loop currents that arise in multi-drop field wiring topologies where transmitters reference different earth potentials. In long-cable oil and gas installations, ground potential differences of 5–30 V between field junction boxes and the control room are common; without this isolation, differential-mode noise would corrupt the 16-bit ADC output at the LSB level.

16-Bit Sigma-Delta ADC: The converter architecture uses oversampling and digital filtering to achieve the stated ±0.1% full-scale accuracy. The effective number of bits (ENOB) at the module’s update rate is sufficient to resolve a 4–20 mA span into 65,536 discrete steps — equivalent to a resolution of approximately 0.244 µA per count. For a 0–100 bar pressure transmitter, this translates to a measurement resolution of approximately 0.0015 bar, well within the requirements of most process control loops.

EMC Design: The PCB layout follows IEC 61000-4 series immunity requirements. Differential-mode and common-mode filter inductors on each input channel attenuate conducted RF interference (IEC 61000-4-6, 10 V/m) before the signal reaches the ADC. The module housing provides shielding continuity through the FCN/FCJ base unit chassis, contributing to the system-level radiated immunity performance.

Backplane Bus Interface: Communication with the FCN/FCJ CPU module occurs over the proprietary STARDOM backplane bus. The NFAI141-S00 presents its digitized channel data to the CPU at the bus scan rate, which is deterministic and synchronized with the controller’s task execution cycle. This synchronization eliminates the jitter that would arise from asynchronous serial communication between a standalone signal conditioner and a controller — a critical property for cascade control loops where the derivative term is sensitive to measurement timestamp variation.

System Integration Benefits

  • Zero-Configuration Slot Recognition: The FCN/FCJ CPU automatically identifies the NFAI141-S00 upon power-up via the backplane bus enumeration protocol. No DIP switch addressing or manual I/O mapping is required; the module’s channel data appears in the controller’s I/O table at the slot-defined address, reducing commissioning time and eliminating address-conflict errors.
  • Deterministic Scan Synchronization: Channel data is latched and transferred to the CPU in synchronization with the controller task cycle. This property ensures that all four analog inputs are sampled within the same scan window, eliminating inter-channel timestamp skew in multi-variable control strategies such as ratio control or feedforward compensation.
  • Dual-Mode Input Flexibility: A single module type handles both 4–20 mA transmitters and 1–5 V sensors. This reduces the number of distinct spare-part SKUs that a plant maintenance department must stock, and simplifies panel design by eliminating the need for separate current-input and voltage-input module types.
  • Integrated Diagnostics: The module reports open-circuit and over-range conditions to the FCN/FCJ CPU via the backplane bus. These diagnostic flags are accessible in the controller’s I/O status registers and can be mapped to alarm outputs or HMI displays without additional programming, providing real-time visibility into field wiring integrity.
  • Hot-Swap Capability: The STARDOM FCN/FCJ base unit supports module replacement under power in non-SIL applications. The NFAI141-S00 can be extracted and reinserted without shutting down the controller, reducing planned maintenance downtime in continuous-process installations.
  • Galvanic Isolation for Ground-Loop Immunity: The channel-to-channel and channel-to-bus isolation eliminates ground-loop interference in multi-drop field wiring. This is particularly significant in geographically distributed installations — pipeline SCADA nodes, offshore platforms — where earth potential differences between field devices and the control room can reach tens of volts.
  • High-Resolution Measurement for Tight Loop Tuning: The 16-bit ADC resolution supports PID loop tuning with integral windup thresholds and derivative filters that operate at sub-percent-of-span precision. Controllers tuned on 12-bit input data often exhibit limit cycling near setpoint; the NFAI141-S00’s resolution eliminates this artifact in most process applications.
  • Compliance with IEC 61131-2 and IEC 61000-4 Series: The module meets the electrical requirements and EMC immunity levels defined in these standards, ensuring compatibility with the electromagnetic environment of industrial switchgear rooms, motor control centers, and outdoor RTU enclosures without additional filtering hardware.

Quality Assurance & Global Logistics

Every NFAI141-S00 unit dispatched from our Xiamen, China facility is sourced as genuine YOKOGAWA OEM hardware. Units are procured through authorized distribution channels and verified secondary-market partners with documented traceability to original YOKOGAWA manufacturing. Before shipment, each module undergoes visual inspection covering connector pin condition, PCB surface integrity, label legibility, and housing continuity. Where bench test fixtures are available, functional verification confirms channel response and backplane bus handshake behavior against reference FCN/FCJ base units.

A 12-month warranty against manufacturing defects and DOA failures is provided on all units. Serial numbers and firmware revision levels are documented at dispatch. Original YOKOGAWA packaging is retained and shipped where available; units without original packaging are protected with anti-static foam and double-wall carton construction rated for international air freight handling.

Standard export shipment is via DHL Express or FedEx International Priority from Xiamen Gaoqi International Airport (XMN). Transit times to major industrial hubs: Europe 3–5 business days, North America 4–6 business days, Southeast Asia 2–3 business days, Middle East 4–5 business days. Export documentation including commercial invoice, packing list, and certificate of origin is prepared for all shipments. A certificate of conformance (CoC) is available upon request prior to order placement.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier