330106-05-30-20-02-CN In Stock — Every Hour of Downtime Costs More Than This Probe
Your compressor tripped at 02:40. The DCS is showing a proximitor gap voltage fault. Maintenance pulled the probe — cable sheath cracked, tip corroded, signal dead. You need a Bently Nevada 330106-05-30-20-02-CN and you need it before the morning shift handover. We stock it. We ship it today.
The 330106-05-30-20-02-CN is a 5 mm eddy current proximity probe from the Bently Nevada 3300 XL 8 mm Proximity Transducer System — the most widely deployed non-contact vibration sensing platform in rotating machinery protection worldwide. This specific configuration carries a 300 mm (30 cm) armored extension cable, a 20-foot (6 m) interconnect cable, and a standard CN coaxial connector. It is factory-matched and calibrated for use with the 3300 XL 8 mm Proximitor driver. Substituting an unmatched probe introduces scale factor error that will corrupt your vibration amplitude readings and potentially mask a developing bearing fault or rotor rub. There is no acceptable workaround — the correct part number is the only answer.
We operate from Xiamen, China, with direct access to DHL Express and FedEx International Priority lanes. Parts clear customs with full commercial invoice and HS code documentation. Most destinations in Southeast Asia, the Middle East, and Europe receive shipments within 3–5 business days from order confirmation. North America typically 4–6 days. If your plant is in a critical shutdown window, tell us — we will escalate to the fastest available routing.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 330106-05-30-20-02-CN |
| Brand | Bently Nevada (Baker Hughes) |
| Series | 3300 XL 8 mm Proximity Transducer System |
| Probe Diameter | 5 mm |
| Extension Cable Length | 300 mm (30 cm) — armored |
| Interconnect Cable Length | 20 ft (approx. 6.1 m) |
| Connector Type | CN — standard coaxial |
| Sensing Technology | Eddy current, non-contact |
| Compatible Proximitor | 3300 XL 8 mm Proximitor Sensor (330180 series) |
| Compatible Monitor | Bently Nevada 3500 Series (3500/40M, 3500/42M, 3500/45, 3500/46) |
| Measurement Function | Radial shaft vibration, axial position, differential expansion |
| Standard Compliance | API 670 |
| Origin | USA (OEM) |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Fault Code: Gap Voltage Out of Range (typically –2 VDC or –18 VDC at 3500 monitor)
This is the most common alarm you will see when this probe fails. The 3300 XL system operates on a nominal gap voltage of –10.0 VDC at the calibrated air gap (typically 1.0 mm for a 5 mm probe). If your monitor is reading near supply rail (–24 VDC) or near zero, the probe is either open-circuit or shorted. Do not attempt to re-gap a damaged probe — replace the full assembly.
Step-by-step replacement procedure:
- Isolate and de-energize the proximitor driver before disconnecting any cables. The –24 VDC supply to the proximitor must be removed. Do not hot-swap — transient voltages can damage the 3500 monitor input card.
- Record the existing gap voltage before removal if the probe is still partially functional. This gives you a baseline for the new installation.
- Remove the probe from the bracket. Note the thread engagement depth — the 330106 series uses a standard M8 thread. Count the turns during removal and replicate during installation to achieve the correct initial gap.
- Inspect the probe tip and target area for scoring, contamination, or shaft surface damage. A damaged target surface will produce a noisy signal even with a new probe.
- Install the new 330106-05-30-20-02-CN. Set the initial gap to 1.0 mm (approximately 1.5 turns back from contact). Tighten the locknut — do not over-torque; the probe body is stainless steel but the threads are fine-pitch.
- Reconnect the extension cable and proximitor. Verify the CN connector is fully seated and the locking collar is engaged. A loose connector is a common source of intermittent faults that are difficult to diagnose in the field.
- Re-energize and verify gap voltage. Target: –10.0 VDC ±0.5 VDC at the calibrated gap. Adjust probe position axially until the reading is within spec, then lock the probe in place.
- Verify scale factor at the 3500 monitor. The 3300 XL 8 mm system has a nominal scale factor of 200 mV/mil (7.87 V/mm). If your monitor is configured for a different scale factor, the vibration amplitude readings will be wrong — check the monitor configuration card before returning the machine to service.
- Clear the monitor bypass and confirm the channel is reading correctly under slow-roll conditions before bringing the machine up to operating speed.
Common mistakes that cause repeat failures:
- Routing the extension cable in contact with hot pipe surfaces — the armored cable is rated for elevated temperatures but sustained contact with steam lines will degrade the sheathing over months.
- Using cable ties that compress the interconnect cable — this creates a localized impedance change that shifts the gap voltage calibration.
- Mixing probe and proximitor from different system generations (e.g., 3300 probe with 3300 XL proximitor) — the scale factors are not identical and the system will not meet API 670 accuracy requirements.
Reliability in Harsh Conditions
The 330106-05-30-20-02-CN is built for environments where most electronic components fail within months. The probe body is machined from 316 stainless steel, providing resistance to the hydrocarbon condensates, H₂S-bearing atmospheres, and aggressive cleaning agents common in refinery and petrochemical service. The armored extension cable uses a stainless steel braid over a PTFE-insulated coaxial core — this combination handles continuous vibration exposure without the micro-fractures that develop in standard PVC-jacketed cables over time.
Operating temperature range spans from –35°C to +177°C at the probe tip, making it suitable for both cryogenic service (LNG compressors) and high-temperature applications (steam turbine bearing housings). The non-contact eddy current sensing principle means there are no moving parts, no wear surfaces, and no mechanical fatigue mechanisms — the probe either works or it does not, which simplifies fault diagnosis considerably.
In offshore and coastal installations where salt fog and humidity are constant factors, the CN connector and cable terminations are the most vulnerable points. Inspect these areas during every planned maintenance window. Apply a thin layer of dielectric grease to the connector mating surfaces if the installation is exposed to wash-down or condensation. The probe body itself requires no maintenance beyond visual inspection.
Vibration endurance: the 3300 XL probe assembly is qualified to withstand the vibration levels generated by the machinery it monitors — a design requirement that eliminates the paradox of a vibration sensor that fails due to vibration. The armored extension cable provides additional mechanical damping at the probe-to-bracket interface.
Global Express Logistics
Our dispatch warehouse is located in Xiamen, Fujian Province, China — one of China’s primary export hubs with direct access to international freight lanes operated by DHL Express, FedEx International Priority, and UPS Worldwide Express.
Standard shipping timeline from order confirmation:
- Southeast Asia (Singapore, Thailand, Malaysia, Indonesia, Vietnam): 2–4 business days
- Middle East (UAE, Saudi Arabia, Kuwait, Qatar): 3–5 business days
- Europe (Germany, Netherlands, UK, France, Italy): 4–6 business days
- North America (USA, Canada): 4–6 business days
- South America (Brazil, Chile, Colombia): 5–8 business days
- Australia / New Zealand: 4–6 business days
Every shipment includes a full commercial invoice, packing list, and HS code declaration (HS 9031.80 for proximity transducers). For destinations requiring import permits or specific customs documentation, notify us at the time of order — we have handled export compliance for industrial components to over 40 countries and can advise on documentation requirements before shipment.
For genuine plant emergencies, we offer same-day dispatch on orders confirmed before 14:00 CST. Contact us via WhatsApp for real-time stock confirmation and shipping cost calculation before placing your order. We do not hold customers to orders that cannot be fulfilled within the agreed timeline — if stock is unavailable, we will tell you immediately and provide an honest lead time estimate.
All shipments are tracked end-to-end. Tracking numbers are provided within 2 hours of dispatch. For high-value orders, we recommend DHL Express with shipment insurance — we can arrange this on your behalf at cost.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.