TOSHIBA In Stock OK

Toshiba B20016RY PLC Output Module – B20016 Series

Request verified availability, condition, replacement risk review, packing options and courier lead time for B20016RY.

Exact partB20016RY RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandTOSHIBA Part NumberB20016RY ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ B20016RY

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
TOSHIBA
Primary Part Number
B20016RY
Product Type
PLC Output Module
Series / Family
PLC
Manufacturer
Toshiba Corporation
Country of Origin
Japan
Catalog Category
I/O Modules
Operating Temp.
0°C to +55°C
Warranty
12 months from date of shipment
Model confirmed for inquiry B20016RY Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Toshiba B20016RY — 16-Point Relay Output Module: Role in Discrete Control Loops

The Toshiba B20016RY is a 16-channel relay output module engineered for integration into Toshiba’s programmable controller (PLC) platform. Within a closed-loop control architecture, this module occupies the final actuator-drive layer: it receives resolved output commands from the CPU’s I/O scan cycle via the backplane bus and converts those logic-level signals into galvanically isolated relay contact closures capable of switching field-side loads — solenoid valves, motor contactors, indicator lamps, and auxiliary relay coils — without exposing the controller’s internal logic circuitry to field transients.

The “RY” suffix in the part designation is Toshiba’s standard nomenclature for relay-type output, distinguishing this module from transistor-output (TR) variants in the B20016 family. Relay contacts provide inherent galvanic isolation between the PLC’s 5 VDC logic bus and the field-side load voltage, which may range from 24 VDC to 240 VAC depending on the connected actuator. This architecture eliminates the need for external interposing relays in most panel designs, reducing BOM cost and wiring complexity.

In a typical discrete manufacturing cell — for example, an automotive body-welding station or a pharmaceutical blister-pack line — the B20016RY handles the final-mile switching of pneumatic valve solenoids, conveyor drive enable signals, and safety-circuit reset coils. Its 16-point density allows a single module slot to control an entire sub-process segment, keeping rack utilization efficient and sparing inventory manageable.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Part Number / SKU B20016RY
Manufacturer Toshiba Corporation
Module Classification Discrete Relay Output Module
Output Points 16 channels
Output Type Relay contact (dry contact, galvanically isolated)
Rated Load Voltage 24 VDC – 240 VAC (field-side, per channel)
Max Switching Current 2 A per channel (resistive load)
Logic Supply Voltage 5 VDC via PLC backplane bus
Isolation Voltage ≥ 1,500 VAC (logic-to-field)
Response Time (ON) ≤ 10 ms (relay mechanical actuation)
Response Time (OFF) ≤ 10 ms
Mechanical Relay Life ≥ 10,000,000 operations (no load)
Electrical Relay Life ≥ 100,000 operations (rated load)
Operating Temperature 0°C to +55°C
Storage Temperature -20°C to +70°C
Relative Humidity 5% – 95% RH (non-condensing)
Vibration Resistance 10 – 57 Hz, 0.075 mm amplitude; 57 – 150 Hz, 9.8 m/s²
Shock Resistance 147 m/s² (15 G), 11 ms duration
Module Weight Approx. 500 g
Country of Origin Japan
Status Indication Per-channel LED (output ON state)
Warranty 12 months from date of shipment

Hardware Logical Analysis

Relay Contact Architecture and Galvanic Isolation: The B20016RY employs electromechanical relay contacts as its output switching element rather than solid-state devices (triacs or transistors). This design choice carries specific engineering implications. Relay contacts present near-zero on-state voltage drop regardless of load type — resistive, inductive, or capacitive — eliminating the thermal derating curves that govern transistor-output modules under high-current or high-ambient-temperature conditions. For inductive loads such as solenoid coils, the relay’s mechanical contact opens the circuit completely, avoiding the leakage current path that exists in triac-based outputs and which can cause partial energization of sensitive actuators.

EMC Design and Field-Side Transient Suppression: Each relay coil driver circuit on the B20016RY incorporates a flyback suppression diode across the coil to clamp the inductive kickback generated when the relay de-energizes. On the field-side terminal block, Toshiba’s design guidelines recommend the addition of RC snubber networks (typically 0.1 µF / 100 Ω) across AC load contacts to suppress contact arc energy and extend relay electrical life. The module’s PCB layout routes logic-side and field-side conductors with adequate creepage and clearance distances per IEC 60664-1 for the rated 300 V working voltage category, providing inherent resistance to conducted EMI from the field wiring harness.

Backplane Bus Interface and I/O Scan Synchronization: The B20016RY communicates with the Toshiba PLC CPU via the proprietary parallel backplane bus. Output data is latched into the module’s output register at the end of each CPU scan cycle. The latch-and-hold architecture ensures that relay states remain stable between scan cycles — a critical behavior for applications where the CPU scan time (typically 1–10 ms) is shorter than the relay mechanical response time (≤ 10 ms). This prevents relay chatter caused by intermediate logic states during scan execution.

Channel Grouping and Common Terminal Configuration: The 16 output channels are organized into groups sharing common terminals, allowing different field-side voltage levels to be used across channel groups within a single module. This multi-voltage grouping eliminates the need for separate output modules when a control panel drives both 24 VDC solenoids and 120 VAC motor starter coils simultaneously — a common requirement in mixed-voltage panel designs for North American and European markets.

System Integration Benefits

  • Direct Backplane Plug-In: The B20016RY mounts directly into any compatible Toshiba PLC rack slot without adapter hardware, preserving the original system’s scan-cycle timing and I/O address mapping. Replacement commissioning time is measured in minutes, not hours.
  • Mixed-Voltage Field Wiring: Channel group isolation allows simultaneous connection of 24 VDC and 120/240 VAC field devices on a single module, reducing rack slot consumption and simplifying panel layout in multi-voltage installations.
  • Zero Leakage Current: Dry relay contacts pass zero current in the open state, eliminating false-energization of sensitive field devices — a known failure mode with solid-state output modules driving high-impedance loads.
  • Per-Channel LED Diagnostics: Each output channel’s LED provides real-time state visibility during commissioning and fault-finding without requiring a programming terminal or diagnostic software connection.
  • Deterministic Output Latching: Output register latch-and-hold behavior ensures relay states are stable and predictable across CPU scan boundaries, supporting deterministic real-time control of time-sensitive actuator sequences.
  • High Channel Density: 16 output points in a single module slot reduces the total rack slot count required for a given I/O point budget, lowering hardware cost and panel footprint for new installations.
  • Broad Load Compatibility: Relay contacts switch resistive, inductive, and lamp loads without derating or external interface relays, simplifying BOM and reducing panel wiring labor.
  • Long-Term Parts Availability: As a catalogued Toshiba PLC module, the B20016RY is available through authorized industrial distributors and specialist suppliers, supporting long-lifecycle plant assets where the control system may remain in service for 15–25 years.
  • ESD-Safe Handling and Packaging: Modules are shipped in anti-static ESD bags with moisture-barrier outer packaging, preserving PCB and relay coil integrity during international transit and warehouse storage.
  • Warranty-Backed Supply: Every unit supplied by siemensplc.com carries a 12-month warranty, providing procurement engineers with documented risk mitigation for MRO and capital project sourcing.

Quality Assurance & Global Logistics

Every Toshiba B20016RY unit dispatched from our Xiamen, China facility is sourced exclusively from verified industrial distribution channels with documented supply-chain traceability. Prior to shipment, each module undergoes a structured pre-dispatch inspection protocol: visual examination of PCB, relay bodies, terminal blocks, and connector pins for mechanical damage; label and date-code verification against Toshiba’s authentic part marking standards; and functional continuity checks on relay contacts and backplane connector pins.

Counterfeit industrial components represent a documented risk in the global MRO market. Our procurement policy enforces a zero-tolerance approach: units sourced from unverifiable secondary channels are excluded from inventory. Customers may request a certificate of conformance and inspection report for any order.

Logistics from Xiamen are executed via DHL Express, FedEx International Priority, and UPS Worldwide Express, with typical transit times of 3–5 business days to major industrial hubs in Europe, North America, Southeast Asia, and the Middle East. For bulk orders, sea freight consolidation via Xiamen Port is available with full export documentation: commercial invoice, packing list, certificate of origin, and HS code classification (HS 8537.10 for PLC I/O modules). All shipments are packed in double-wall corrugated cartons with foam cushioning and ESD-protective inner packaging to withstand the mechanical stresses of international air and sea freight.

Lead time for standard stock items is 1–3 business days from order confirmation. For high-volume or project-specific procurement, dedicated stock reservation is available upon signed purchase order. Our technical team in Xiamen provides pre-sales compatibility verification and post-sales installation support in English and Chinese.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.