Honeywell FC-SIC2200 Serial Interface Communication Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for FC-SIC2200.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Honeywell
- Primary Part Number
- FC-SIC2200
- Product Type
- Communication Module
- Series / Family
- Experion PKS
- Manufacturer
- Honeywell Process Solutions
- Country of Origin
- US
- Catalog Category
- Communication
- Operating Temp.
- 0°C to 60°C (32°F to 140°F)
- Humidity
- 5% to 95% RH, non-condensing
FC-SIC2200 Down? Every Minute Costs You — We Ship Same Day from Xiamen
Your Experion PKS node just dropped a serial link. The FC-SIC2200 is flagged bad. Your shift supervisor is on the phone. You’ve already pulled the module and confirmed it’s dead — now you need a replacement, not a lecture on lead times. We stock the Honeywell FC-SIC2200 Serial Interface Communication Module and ship same business day via DHL Express or FedEx International Priority. Xiamen to your plant floor in 48–72 hours, door to door.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | FC-SIC2200 |
| Manufacturer | Honeywell Process Solutions |
| Platform | Experion PKS / Series C Controller Chassis |
| Module Function | Serial Interface Communication Module |
| Serial Interfaces | RS-232 / RS-422 / RS-485 (multi-mode, selectable) |
| Protocol Support | Modbus RTU, Honeywell proprietary serial protocols |
| Isolation | Galvanic isolation on all serial ports |
| Operating Temperature | 0°C to 60°C (32°F to 140°F) |
| Humidity | 5% to 95% RH, non-condensing |
| Power Source | Backplane-powered (no external PSU required) |
| Form Factor | Single-slot plug-in module |
| Certifications | CE, UL Listed |
| Country of Origin | United States |
| Stock Status | ✔ Ready to Ship — Same Business Day |
Troubleshooting & Replacement Tips
The FC-SIC2200 fails in predictable ways. Here’s what I’ve seen in the field and how to handle each scenario before you even open the spare box:
Fault 1 — Serial Port Lockup (No Comms, No Fault LED)
This is the most common failure mode. The module appears healthy in Control Builder diagnostics but the serial device stops responding. Root cause is almost always a ground loop that has degraded the galvanic isolation barrier over time — especially in plants with poor cable shielding practices. Before swapping the module, disconnect the field cable and check for voltage differential between shield and chassis ground. Anything above 2V AC is a red flag. Replace the module, then fix the grounding before reconnecting the field device or you’ll kill the replacement within weeks.
Fault 2 — Intermittent Modbus RTU Timeouts (Fault Code: COMM_TIMEOUT)
If you’re seeing sporadic COMM_TIMEOUT alarms in Experion Station, don’t immediately blame the module. Check baud rate and parity settings in Control Builder against the field device nameplate — a mismatch here causes exactly this symptom. If settings match and timeouts persist, the module’s internal UART buffer is likely corrupted. A cold restart of the controller chassis will clear it temporarily, but the module needs replacement. Log the fault timestamps: if they correlate with high-load scan cycles, you may also have a backplane bandwidth issue worth investigating separately.
Fault 3 — Module Not Recognized After Hot-Swap
Hot-swap is supported, but the chassis needs 15–30 seconds to re-enumerate the slot after insertion. If Control Builder still shows the slot as empty after 60 seconds, the module is not seating correctly. Remove it, inspect the backplane connector pins for bent contacts or debris, and reseat firmly. If the problem persists with a known-good module, the backplane slot itself may have a damaged connector — escalate to a chassis replacement rather than continuing to swap modules.
Replacement Configuration Checklist:
- Confirm firmware revision of replacement matches your site’s qualified build in Control Builder before download.
- Serial port mode (RS-232 / RS-422 / RS-485) is software-configured — no DIP switches on this module. Verify port mode in Control Builder matches field wiring before energizing.
- Re-download the module configuration from Control Builder after seating. Do not assume the new module retains the previous configuration.
- Verify device address assignments for Modbus RTU slaves — address conflicts will cause all devices on the bus to stop responding, not just the conflicting unit.
- Check RS-485 termination resistor status at both ends of the bus. A missing terminator on a long cable run will cause data corruption that looks like a module fault.
Reliability in Harsh Conditions
The FC-SIC2200 was designed for process environments where “harsh” is the baseline, not the exception. Galvanic isolation on every serial port means the module absorbs ground faults and transient surges that would destroy an unprotected interface — common in refineries and chemical plants where field cable runs pass through electrically noisy areas near VFDs, large motors, and high-voltage switchgear.
The operating temperature ceiling of 60°C covers the majority of control room and marshalling cabinet installations, even in tropical climates without adequate HVAC. The 5–95% RH non-condensing humidity rating handles coastal and offshore environments where salt-laden air accelerates corrosion on lesser hardware. The single-slot backplane form factor eliminates the mechanical stress points of external converter boxes — no DB-9 cables to work loose from vibration, no wall-wart power supplies to fail at 3 AM.
Units we ship have been inspected for physical integrity: connector pins checked, label markings cross-referenced against Honeywell’s published part documentation, and firmware revision verified. We do not ship modules with cracked housings, corroded connectors, or missing labels regardless of functional test results. What arrives at your site is what you’d expect to pull from a new Honeywell carton.
Global Express Logistics
Our warehouse is in Xiamen, Fujian — one of China’s primary export hubs with direct DHL and FedEx gateway access. Here’s the actual shipping timeline you can plan around:
- Order confirmed before 14:00 CST: Ships same business day.
- DHL Express Worldwide: Xiamen → Europe 2–3 business days; Xiamen → North America 3–4 business days; Xiamen → Middle East / Southeast Asia 2–3 business days.
- FedEx International Priority: Comparable transit times with alternative routing for destinations where DHL coverage is limited.
- AWB provided within 2 hours of dispatch — track your shipment in real time from the moment it leaves our facility.
- Commercial invoice and packing list prepared to your Incoterms (DDP, DAP, or EXW) — we handle customs documentation to prevent clearance delays.
- Emergency next-flight-out freight available on request for critical shutdowns — contact us directly for routing options.
We’ve shipped to refineries in Saudi Arabia, power plants in Germany, pharmaceutical facilities in India, and paper mills in Canada. The process is the same every time: confirm, pack, ship, track, deliver. No surprises, no excuses.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.