GE IC695ALG708-CB Analog Input Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for IC695ALG708-CB.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- GE
- Primary Part Number
- IC695ALG708-CB
- Product Type
- PLC Analog Input Module
- Series / Family
- PACSystems
- Manufacturer
- GE / Emerson Automation Solutions
- Country of Origin
- US
- Catalog Category
- I/O Modules
- Operating Temp.
- 0°C to 60°C
IC695ALG708-CB: Eight Channels Down — Every Second Costs You Money
Your PACSystems RX3i rack just threw a module fault. The HMI is alarming. Your process engineer is on the phone. You don’t have time for a distributor quoting you a 10-week lead time on a module that’s been in production for years. The GE IC695ALG708-CB is an 8-channel universal analog input module — voltage, current, thermocouple, RTD, all configurable per channel in software. We have it in stock at our Xiamen warehouse. It ships today. That’s the whole pitch.
⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | IC695ALG708-CB |
| Manufacturer | GE / Emerson Automation Solutions |
| Platform | PACSystems RX3i |
| Module Function | Universal Analog Input |
| Number of Channels | 8 (individually configurable) |
| Voltage Input Ranges | ±10V, 0–10V, ±5V, 0–5V, 1–5V |
| Current Input Ranges | 0–20mA, 4–20mA, ±20mA |
| Thermocouple Types | J, K, T, E, R, S, B, N |
| RTD Types | Pt100, Pt1000, Ni120 (2-wire, 3-wire) |
| ADC Resolution | 16-bit |
| Isolation | Channel-to-channel + channel-to-backplane |
| Backplane Compatibility | IC695CHS007 / CHS012 / CHS016 (single slot) |
| Backplane Power | 1.1A @ 3.3V |
| Operating Temperature | 0°C to 60°C |
| Configuration Software | Proficy Machine Edition (PME) 8.0+ |
| Certifications | CE, UL, cUL |
| Module Weight | ~300g |
| Availability | ✅ In Stock — Ships from Xiamen Same Day |
Troubleshooting & Replacement Tips
Pulled the failed module. New one in hand. Here’s what to watch before you close the panel door:
Hardware revision suffix (-CB vs -CC vs -EA): These suffixes indicate PCB revision, not a different product. Functionally interchangeable in the vast majority of applications. However, if your Proficy Machine Edition project was built targeting a specific revision, PME may generate a hardware mismatch diagnostic on the first CPU download. Resolution: open the hardware configuration in PME, update the module revision to match the installed unit, and re-download. Two minutes. Not a re-commission.
Channel configuration is not stored on the module: Unlike some legacy analog modules with onboard DIP switches or EEPROM-stored calibration, the IC695ALG708-CB holds zero configuration locally. Every channel parameter — input type, engineering unit range, filter time constant, alarm limits — lives in the PME project and is pushed to the module at CPU startup. If you install the replacement and all channels default to ±10V voltage input, the CPU hasn’t downloaded the project yet, or it’s sitting in Stop mode. Force a program download from PME or cycle the CPU to Run. The module will configure itself within one scan cycle.
Thermocouple open-circuit fault (Diagnostic Code 16#0010): Nine times out of ten this is a wiring polarity reversal at the terminal block. The IC695ALG708-CB uses a dedicated field wiring unit — IC695ACC402 or equivalent — with clearly labeled + and − terminals per channel. Swap the TC leads and the fault clears immediately. If the fault persists across multiple TC channels simultaneously, suspect the cold-junction compensation (CJC) sensor on the terminal block. A loose or unseated CJC sensor causes erratic readings on every thermocouple channel at once because the module cannot compensate for ambient temperature at the terminal block.
RTD reading pegged at maximum scale: The module sources a small excitation current through the RTD element and measures the resulting voltage drop. An open circuit anywhere in the RTD loop — broken wire, loose terminal screw, corroded connector — will rail the reading to the top of scale. For 3-wire RTD configurations, verify all three conductors are landed. The compensation wire (the third wire that balances lead resistance) is the most commonly missed connection during field wiring. Without it, the module cannot cancel lead resistance and will report a consistently high temperature.
Module not recognized after seating: The RX3i backplane connector requires firm, positive engagement — you should feel and hear the module click into the backplane. A partially seated module will either not appear in the CPU’s I/O scan or will generate intermittent slot faults under vibration. Also verify in PME that the target slot is not configured as “empty” — a slot explicitly set to empty in the hardware configuration will be ignored by the CPU regardless of what’s physically installed.
4–20mA channel reading consistently low by 0.3–0.8mA: The IC695ALG708-CB presents approximately 250Ω input impedance on current channels. If your field transmitter is loop-powered and the total loop resistance (cable + module input) is pushing the transmitter’s compliance voltage limit, you’ll see a systematic low-side offset. Measure loop supply voltage at the transmitter terminals under load. Also check for a ground loop — a potential difference between the field instrument ground and the PLC chassis ground will inject a common-mode offset current into the measurement.
Reliability in Harsh Conditions
The IC695ALG708-CB wasn’t designed for a climate-controlled server room. It was designed for the kind of industrial environment where the ambient temperature swings 20°C between day and night shifts, where the panel is mounted 10 meters from a 500-ton press, and where the maintenance crew uses a pressure washer on the factory floor every Friday.
The full channel-to-channel and channel-to-backplane isolation architecture is the module’s most underappreciated feature. In real-world installations — steel mills, chemical reactors, offshore platforms, water treatment facilities — ground potential differences between field instruments and the control panel can easily exceed 30–50V. Without proper isolation, a single ground fault on one field device can corrupt readings across the entire module or, in worst cases, damage the backplane. The IC695ALG708-CB’s isolation topology contains faults at the channel level. One bad field device stays one bad channel.
Vibration performance is validated to IEC 60068-2-6. The PCB carries a conformal coating that resists condensation, airborne particulates, and mild chemical exposure — relevant in food and beverage processing, pulp and paper mills, and coastal installations where salt-laden air accelerates corrosion on unprotected electronics. The 0°C to 60°C operating range covers the full envelope of most industrial panel enclosures without derating.
The 16-bit ADC maintains its linearity specification across the entire operating temperature range. Cheaper 12-bit or 13-bit modules drift measurably as ambient temperature rises — acceptable for coarse control loops, unacceptable for precision dosing, custody transfer measurement, or any process where a 0.1% measurement error has regulatory or quality consequences. The IC695ALG708-CB holds calibration. You don’t need to re-zero it after a hot summer shutdown.
Field replaceability was a design requirement, not an afterthought. No jumpers to set. No DIP switches to match. No manual calibration procedure after installation. A technician who has never seen this module before can have it seated, configured, and returning live process values in under 30 minutes — working from the PME project file alone, without the original commissioning engineer on-site.
Global Express Logistics
Xiamen is not a random warehouse location. It is one of China’s primary electronics export hubs, with direct DHL and FedEx gateway operations, multiple daily international flight departures, and customs clearance infrastructure built for high-frequency industrial parts exports. When your module ships from here, it moves fast.
Same-day dispatch: Orders confirmed before 15:00 CST (UTC+8) ship the same business day. The module is inspected against the order, anti-static bagged, cushion-wrapped, and boxed with a printed packing list, commercial invoice, and test record. No exceptions, no “we’ll try to get it out tomorrow.”
Carrier options: DHL Express Worldwide and FedEx International Priority are our standard carriers. Both provide door-to-door tracking with active shipment monitoring. For time-critical orders, we can pre-book a specific flight departure from Xiamen Gaoqi International Airport — request this at order confirmation.
Typical transit times:
- Southeast Asia (SG, MY, TH, VN, ID): 1–2 business days
- Northeast Asia (JP, KR, TW): 1–2 business days
- Europe (DE, NL, FR, UK, PL): 3–5 business days
- North America (US, CA, MX): 3–5 business days
- Middle East (AE, SA, QA): 3–5 business days
- South Asia (IN, PK, BD): 3–4 business days
- Australia / New Zealand: 3–4 business days
- Africa: 5–7 business days
Export documentation: Every shipment includes a commercial invoice with accurate HS code classification (HS 8537.10 for programmable logic controllers and modules), country of origin declaration, and full packing list. EU customers can request an EUR.1 movement certificate. All export compliance checks are completed before dispatch — no shipments held at origin customs due to documentation errors.
Tracking and proactive communication: A DHL or FedEx tracking number is sent to you within 2 hours of dispatch. We monitor active shipments — if a carrier delay is flagged in the tracking system, we notify you before you have to ask. If a shipment is held at destination customs, we provide the documentation support needed to clear it.
Emergency freight: If standard express transit time is not fast enough for your situation, contact us directly. We have established relationships with freight forwarders who can arrange next-flight-out courier service for genuinely critical plant-down scenarios. This is not a standard service — it is reserved for real emergencies — but it is available.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.