Pepperl+Fuchs KFD2SR2EX2.W Isolated Switch Amplifier – KFD2 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for KFD2SR2EX2.W.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Pepperl+Fuchs
- Primary Part Number
- KFD2SR2EX2.W
- Product Type
- Isolated Switch Amplifier
- Product Family
- Other series
- Manufacturer
- Pepperl+Fuchs
- Country of Origin
- DE
- Model Function
- 2-Channel Isolated Switch Amplifier
- Catalog Category
- Sensors & Switches
- Warranty
- 12 months against manufacturing defects
Pepperl+Fuchs KFD2SR2EX2.W — 2-Channel Galvanically Isolated Switch Amplifier for Hazardous-Area Signal Conditioning
In process automation architectures where field instrumentation resides inside classified zones — ATEX Zone 0/1 gas atmospheres or Zone 20/21 dust environments — the signal interface between the hazardous area and the safe-area control system is a critical engineering boundary. The KFD2SR2EX2.W addresses this boundary with a dual-channel galvanic isolation topology, intrinsic-safety energy limiting on the field side, and relay output switching on the safe-area side. It is a member of Pepperl+Fuchs’ KFD2 platform, which has established a long-standing reference position in SIL-rated safety instrumented systems across refining, petrochemical, and offshore sectors.
The module accepts NAMUR-compliant proximity sensor inputs (EN 60947-5-6) and dry mechanical contacts from the hazardous area, conditions both channels independently, and delivers relay-switched outputs to DCS digital input cards, safety relay modules, or PLC discrete input terminals. Its IEC 61508 SIL 2 certification means the module’s PFD and PFH values have been independently validated, reducing the functional-safety engineering burden during SIL verification for IEC 61511 safety loops.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Value |
|---|---|
| Model / Part Number | KFD2SR2EX2.W |
| Manufacturer | Pepperl+Fuchs |
| Series | KFD2 Isolated Barrier Platform |
| Function | 2-Channel Isolated Switch Amplifier |
| Input Type | NAMUR proximity sensor (EN 60947-5-6) / dry mechanical contact |
| Field-Side Supply to Sensor | 8 V DC / 8 mA (NAMUR standard) |
| Output Type | Relay contact output (SPDT) |
| Number of Channels | 2 (independent) |
| Supply Voltage | 20–35 V DC (Power Rail or direct terminal) |
| Current Consumption | ≤ 70 mA at 24 V DC |
| Galvanic Isolation | Input / Output / Power — three-way isolation, ≥ 500 V AC reinforced |
| Safety Integrity Level | SIL 2 per IEC 61508 |
| Hazardous Area Classification | ATEX II 2 G Ex ia IIC T6 / Zone 0, 1, 2 (Gas); Zone 20, 21, 22 (Dust) |
| Certifications | ATEX, IECEx, cULus |
| Ambient Operating Temperature | −20 °C to +60 °C |
| Storage Temperature | −25 °C to +85 °C |
| Mounting | 35 mm DIN rail, 20 mm module width |
| Housing Material | Polycarbonate, IP20 |
| Relay Contact Rating | 250 V AC / 2 A (resistive load) |
| Response Time | ≤ 10 ms (sensor state change to relay output) |
| Wire-Break Detection | Yes — per NAMUR NE 43 |
| Short-Circuit Detection | Yes — per NAMUR NE 43 |
| LED Indication | Per-channel status LED (green = normal, off/red = fault) |
| Weight | approx. 100 g (module only) |
| Warranty | 12 months against manufacturing defects |
Hardware Logical Analysis
Galvanic Isolation Architecture: The KFD2SR2EX2.W employs transformer-based galvanic isolation rather than optocoupler-only designs. This distinction matters in high-noise industrial environments: transformer isolation provides a reinforced insulation barrier rated at ≥ 500 V AC between the field circuit, the output circuit, and the power supply rail — three independent isolation domains. Optocoupler-based designs typically offer only basic insulation and are susceptible to common-mode transients in plants with multiple earthing reference points. The transformer topology eliminates ground-loop currents that would otherwise introduce DC offset errors or false switching events on the relay output.
Intrinsic Safety Energy Limiting (Field Side): On the hazardous-area terminals, the module implements entity-parameter-based energy limiting: maximum open-circuit voltage (Uo) and short-circuit current (Io) are constrained to values below the minimum ignition energy of the target gas group (IIC — hydrogen, acetylene). This is achieved through a combination of series resistors and Zener diode clamps embedded in the field-side input circuit. The entity parameters (Uo, Io, Po, Co, Lo) are documented on the module label and in the ATEX certificate, enabling cable capacitance and inductance calculations for the maximum permissible field wiring length.
NAMUR Signal Evaluation Logic: The internal comparator evaluates field-side current against four NAMUR NE 43 thresholds: short-circuit (< 1 mA), fault low (1–2.1 mA), normal off (2.1–3 mA), normal on (3–21 mA), and wire-break (> 21 mA). This five-state discrimination allows the module to distinguish a genuine sensor-off state from a broken cable — a capability absent in simple threshold-only designs. The relay output reflects the logical sensor state, while the LED indicator changes state for both wire-break and short-circuit faults, providing panel-level diagnostics without requiring a handheld communicator.
EMC Design: The module’s PCB layout incorporates ground-plane shielding between the field-side and safe-side circuits, and the DIN-rail mounting clip provides a low-impedance chassis earth path. Conducted and radiated immunity is validated to EN 61326-1 (industrial environment), covering 10 V/m radiated fields and ±4 kV EFT/burst on power supply lines. In practice, this means the module maintains correct relay state during welding operations, VFD switching transients, and high-voltage bus switching events common in process plant environments.
Power Rail Integration: The module’s rear connector mates with the Pepperl+Fuchs Power Rail bus, distributing 24 V DC across all mounted modules without individual power wiring. This eliminates terminal block proliferation in large marshalling cabinets and reduces wiring error probability. The Power Rail also carries a common earth reference, ensuring consistent isolation performance across all modules in a multi-channel installation.
System Integration Benefits
- Direct DCS/PLC Compatibility: Relay output contacts interface directly to 24 V DC discrete input cards on Siemens S7-300/400/1500, ABB System 800xA, Emerson DeltaV, Honeywell Experion PKS, and Yokogawa CENTUM VP without additional signal conditioning hardware.
- SIL 2 Pre-Validation: Published PFD (Probability of Failure on Demand) and PFH (Probability of Failure per Hour) values from the Pepperl+Fuchs Safety Manual can be directly inserted into LOPA or fault-tree calculations, eliminating the need for in-house reliability testing during SIL verification.
- Dual-Channel Density: Two independent signal paths in a 20 mm module width achieve a channel density of 100 channels per meter of DIN rail — approximately double that of single-channel barrier alternatives — reducing marshalling cabinet footprint and associated civil/structural costs.
- Universal Input Compatibility: Accepts both NAMUR proximity sensors and conventional dry contacts on the same terminals without hardware modification, simplifying mixed-sensor installations and reducing spare-part inventory to a single module type.
- Deterministic Response Time: ≤ 10 ms relay switching latency from field sensor state change to output contact closure ensures the module does not introduce measurable delay into safety loop response time calculations under IEC 61511 Clause 11.
- Diagnostic Transparency: Per-channel LED fault indication and NAMUR NE 43 wire-break/short-circuit detection provide first-level diagnostics visible at the cabinet door, reducing mean time to repair (MTTR) by enabling technicians to isolate faults without loop testing equipment.
- Wide Supply Tolerance: 20–35 V DC supply range accommodates voltage drops across long cable runs from remote power distribution panels, maintaining correct operation without local voltage regulation.
- Reduced Wiring Complexity via Power Rail: Power Rail bus eliminates per-module power wiring, reducing terminal block count by up to 40% in large installations and lowering the probability of wiring errors during commissioning.
- Long-Term Availability: The KFD2 platform has maintained backward-compatible form factor and terminal assignment across multiple product generations, protecting the investment in existing cabinet layouts and wiring documentation when modules require replacement.
- Global Certification Coverage: Simultaneous ATEX (EU), IECEx (international), and cULus (North America) certification on a single module eliminates the need for region-specific variants in multinational plant portfolios.
Quality Assurance & Global Logistics
Every KFD2SR2EX2.W unit supplied through siemensplc.com is sourced from verified distribution channels carrying authentic Pepperl+Fuchs factory origin. Each module undergoes a structured pre-shipment verification protocol before dispatch from our Xiamen, China facility:
- Physical inspection of housing integrity, terminal block condition, and manufacturer label legibility
- Serial number and date-code cross-reference against manufacturer production records where accessible
- Functional power-on test: supply voltage applied, LED status verified, relay output continuity confirmed on both channels
- Original manufacturer packaging preserved; anti-static packaging applied for transit protection
- Certificate of Conformity and ATEX/IECEx certificate copies provided with each shipment on request
Logistics from Xiamen, China: Xiamen is a designated free-trade port with direct air freight connections to major industrial hubs across Europe, the Middle East, Southeast Asia, and the Americas. Standard dispatch lead time is 1–3 business days from order confirmation. Express air freight via DHL Express or FedEx International Priority delivers to most destinations within 3–5 business days. Sea freight consolidation is available for bulk orders. Full export documentation — commercial invoice, packing list, certificate of origin, and MSDS where required — is prepared in compliance with destination country import regulations. Customs HS code 8536.49 applies to this product category for import duty classification purposes.
A 12-month warranty against manufacturing defects is provided from the date of shipment. Warranty claims are assessed against the pre-shipment inspection record and processed in coordination with the manufacturer’s authorized service network.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.