FOXBORO P0926MX Signal Splitter / Isolator
Request verified availability, condition, replacement risk review, packing options and courier lead time for P0926MX.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- FOXBORO
- Primary Part Number
- P0926MX
- Product Type
- Signal Splitter / Isolator
- Series / Family
- I/A Series
- Manufacturer
- FOXBORO (Schneider Electric / Invensys)
- Country of Origin
- FR
- Catalog Category
- DCS & Safety Modules
- Operating Temp.
- 0°C to +60°C
- Humidity
- 5–95% RH, non-condensing
FOXBORO P0926MX – Every Hour of Downtime Costs You. We Ship Today.
Your I/A Series DCS loop is dead. The historian is blind. The SIS is running on a single input. You’ve already traced the fault to the P0926MX signal splitter — now the only question is how fast you can get a replacement on the rail. We stock the FOXBORO P0926MX in Xiamen and dispatch same-day via DHL/FedEx Express. No waiting on OEM lead times. No grey-market gamble. One call, one unit, back online.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | P0926MX | ✅ Ready to Ship |
| Manufacturer | FOXBORO (Schneider Electric / Invensys) | |
| Module Function | Signal Splitter / Galvanic Isolator | |
| Input Signal | 4–20 mA (2-wire / 4-wire transmitter) | |
| Output Channels | 2 × fully isolated 4–20 mA outputs | |
| Isolation Voltage | ≥ 500 V DC (ch-to-ch and ch-to-GND) | |
| Accuracy | ±0.1% of full scale | |
| Max Load per Output | 0–600 Ω | |
| Supply Voltage | 24 V DC (loop-powered or external) | |
| Operating Temperature | 0°C to +60°C | |
| Storage Temperature | −40°C to +85°C | |
| Humidity | 5–95% RH, non-condensing | |
| Mounting | DIN rail, compact form factor | |
| Certifications | CE, UL listed | |
| Platform | Foxboro I/A Series, SPEC 200, generic 4–20 mA | |
| Origin | Xiamen, China — Export Ready | ✅ Ready to Ship |
Troubleshooting & Replacement Tips
Top failure modes on the P0926MX — what you’re probably seeing right now:
1. Output Channel Frozen / Stuck at 4 mA or 20 mA
Most common failure. Internal DC-DC converter or optocoupler degradation causes one output to rail. Verify by disconnecting Output 2 load and measuring open-circuit voltage — if it reads supply rail, the output driver is gone. The input side may still be functional; don’t let that fool you into chasing the transmitter.
2. Ground Loop Noise After Module Swap
If you replaced the P0926MX and now see 50/60 Hz noise on the loop, check that the shield drain wire is terminated at one end only (typically the marshalling cabinet side). The P0926MX’s isolation barrier is only effective if you haven’t inadvertently created a new ground path through the cable shield.
3. HART Signal Not Passing Through
The P0926MX is an analog-only splitter. HART FSK signals (1200/2200 Hz) are attenuated by the isolation barrier in most revisions. If your loop requires HART transparency for valve positioner or transmitter configuration, confirm the hardware revision suffix before installation. Some later revisions added HART pass-through; earlier ones did not.
4. Output 2 Loading Down Output 1
If both outputs share a common reference in a degraded unit, loading Output 2 (e.g., connecting a 250 Ω historian input) will pull Output 1 down. Isolate each output channel independently during bench verification before reinstalling.
Replacement Procedure — Field Steps:
- De-energize the 24 V DC supply rail feeding the P0926MX. Do not rely on loop power alone — confirm with a multimeter at the supply terminals.
- Label all three wiring groups (Input+/−, Output 1 +/−, Output 2 +/−) before disconnecting. The terminal block layout is not always intuitive after years of cable bundling.
- Verify the replacement unit’s hardware revision matches your system BOM. Check the label on the side of the housing — revision letter is printed after the part number.
- No DIP switch or jumper configuration is required for standard 4–20 mA operation. If your application uses an external power supply (non-loop-powered mode), confirm the power configuration jumper position matches the original unit before energizing.
- Re-energize and verify both output channels independently. Apply a known 12 mA input (50% span) and confirm both outputs read 12 mA ±0.1% at the receiving end.
- Check FBM diagnostic in the I/A Series workstation — the analog input should return to normal range within one scan cycle after the module is back online.
Configuration Note: The P0926MX has no firmware, no address setting, and no software configuration. It is a passive signal conditioning module. If your I/A Series FBM is still reporting a fault after physical replacement, the issue is upstream (transmitter) or downstream (FBM card itself) — not the splitter.
Reliability in Harsh Conditions
Marshalling cabinets in refineries and chemical plants are not the clean, climate-controlled environments that datasheets assume. The P0926MX was designed with this reality in mind.
Vibration: DIN rail mounting with positive locking clip prevents the module from walking off the rail under continuous mechanical vibration — common near compressor skids and pump stations. The internal PCB is conformal-coated on production units, protecting solder joints from micro-fracture under cyclic mechanical stress.
Thermal Cycling: With an operating range of 0°C to +60°C and storage down to −40°C, the P0926MX handles the thermal shock of outdoor field enclosures in northern climates and the sustained heat of tropical process areas. The solid-state isolation barrier has no electrolytic capacitors in the signal path — the primary aging mechanism in competing designs.
Humidity and Condensation: Rated to 95% RH non-condensing. In practice, marshalling cabinets in coastal or offshore environments regularly exceed this during seasonal humidity swings. Units sourced through siemensplc.com are inspected for corrosion on terminal blocks and PCB surfaces before dispatch — a failure point that catalogue suppliers don’t check.
EMI/RFI Immunity: The galvanic isolation barrier provides inherent common-mode rejection. In plants with large VFD installations or high-current bus bars running parallel to signal cable trays, the P0926MX’s ≥500 V isolation voltage provides a meaningful safety margin against induced transients that would corrupt a non-isolated signal path.
Global Express Logistics
Stock is held at our Xiamen facility, positioned for rapid export to any destination worldwide. Here’s exactly how the process works from the moment you contact us:
Hour 0 — Contact & Confirmation: You reach us via email or WhatsApp with your part number and required quantity. We confirm stock availability and provide a proforma invoice within 2 hours during business hours (UTC+8).
Hour 2–4 — Payment & Pick: Upon payment confirmation (T/T, PayPal, or platform checkout), the unit is pulled from stock, inspected, and packaged in anti-static foam with humidity indicator card. Export documentation is prepared in parallel: commercial invoice, packing list, and certificate of conformance.
Hour 4–8 — Dispatch: Shipment is booked with DHL Express or FedEx International Priority, depending on destination and your preference. Tracking number is sent to you within 30 minutes of carrier pickup.
Transit Times (typical, not guaranteed):
- Southeast Asia (SG, MY, TH, ID): 1–2 business days
- Middle East (AE, SA, QA, KW): 2–3 business days
- Europe (DE, NL, GB, FR): 3–4 business days
- North America (US, CA): 3–5 business days
- Australia / New Zealand: 3–4 business days
- South America (BR, CL, PE): 4–6 business days
For genuine plant emergency situations, contact us directly on WhatsApp — we can arrange Saturday dispatch and coordinate with DHL’s on-call export team for next-flight-out options to critical destinations.
All shipments include full export documentation compliant with Chinese customs regulations. HS code classification and commercial invoice valuation are handled by our logistics team — you receive a clean, customs-ready shipment package.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.