Siemens 715-083930-001 Digital Output Module – SIMATIC S7-300
Request verified availability, condition, replacement risk review, packing options and courier lead time for 715-083930-001.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 715-083930-001
- Product Type
- PLC Digital Output Module
- Series / Family
- SIMATIC S7-300
- Country of Origin
- DE
- Catalog Category
- I/O Modules
- Operating Temp.
- 0 °C to +60 °C
- Warranty
- 12 months from date of shipment
Siemens 715-083930-001 Digital Output Module — Signal-Layer Architecture in SIMATIC S7-300 Control Loops
The Siemens 715-083930-001 is a digital output module designed for integration within the SIMATIC S7-300 programmable logic controller platform. In a distributed or centralized control architecture, the digital output module occupies the final stage of the control loop: it receives processed command signals from the CPU via the S7-300 backplane bus and converts them into discrete 24 V DC switching signals that actuate field devices — contactors, solenoid valves, motor starters, and indicator lamps. The module’s role is not passive relay switching; it is an active, diagnostics-capable output stage that participates in the controller’s process image update cycle at every scan.
Within the S7-300 rack, the 715-083930-001 communicates over the P-bus (peripheral bus) at a data transfer rate synchronized to the CPU’s cycle time, typically in the range of 1–10 ms for standard applications. Each output channel is individually addressable within the process image output table (PAA), allowing the CPU to write discrete bit-level commands without affecting adjacent channels. This bit-granular addressing is fundamental to deterministic output behavior in time-critical sequences such as sequential motor start-stop logic or valve interlock chains.
The module’s output transistors are protected against short-circuit and overload conditions through integrated electronic protection circuits. Unlike electromechanical relay outputs, the solid-state output stage of the 715-083930-001 provides a switching response time in the sub-millisecond range, which is essential for applications requiring precise timing — for example, pulse-width modulated valve control or coordinated multi-axis positioning sequences where output jitter must remain below 0.5 ms.
Diagnostics transparency is a defining characteristic of this module. Each channel supports individual fault detection: short-circuit, wire break (where applicable), and supply voltage monitoring are reported back to the CPU via the diagnostic interrupt mechanism. The CPU can read the diagnostic data record (DS 0 and DS 1) using SFB 52 or standard STEP 7 / TIA Portal diagnostic functions, enabling the control program to implement fault-tolerant logic — for instance, switching to a safe output state or triggering an alarm without halting the entire PLC scan cycle.
The 715-083930-001 is engineered for installation in industrial environments classified up to Pollution Degree 2 per IEC 60664-1, with an operating temperature range of 0 °C to +60 °C and storage temperature of -40 °C to +70 °C. The module mounts on a standard S7-300 DIN rail rack and connects via the backplane bus connector — no additional wiring between modules is required for bus communication. Field wiring connects to the front connector (20-pin), which can be removed and reinserted without disturbing the module itself, reducing mean time to repair (MTTR) during maintenance cycles.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | 715-083930-001 |
| Product Family | SIMATIC S7-300 |
| Module Type | Digital Output Module (DO) |
| Output Voltage | 24 V DC |
| Output Current per Channel | 0.5 A (standard) / 2 A (high-current channels) |
| Number of Output Channels | 16 (configurable grouping) |
| Output Type | Transistor, sourcing (PNP) |
| Short-Circuit Protection | Electronic, per channel |
| Switching Frequency | Up to 100 Hz (resistive load) |
| Backplane Bus Interface | SIMATIC S7-300 P-bus |
| Supply Voltage (L+) | 24 V DC (20.4 V – 28.8 V) |
| Current Consumption (backplane) | ≤ 80 mA at 5 V DC |
| Power Dissipation | ≤ 4.5 W (all channels active) |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | -40 °C to +70 °C |
| Relative Humidity | 10 % to 95 %, non-condensing |
| Degree of Protection | IP20 (IEC 60529) |
| Pollution Degree | 2 (IEC 60664-1) |
| Mounting | S7-300 DIN rail rack, slot 4–11 |
| Front Connector | 20-pin screw or spring-type (not included) |
| Dimensions (W × H × D) | 40 mm × 125 mm × 120 mm |
| Weight | Approx. 200 g (without front connector) |
| EMC Compliance | EN 61000-6-2 (immunity), EN 61000-6-4 (emission) |
| CE Marking | Yes |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The output stage of the 715-083930-001 employs optocoupler-based galvanic isolation between the backplane logic side (5 V DC, referenced to CPU ground) and the field-side load circuit (24 V DC, referenced to the load power supply ground). This isolation barrier — typically rated at 500 V AC isolation voltage — prevents ground loops and common-mode transients generated by inductive field devices from propagating back into the CPU’s logic circuitry. In environments with variable-frequency drives (VFDs), large contactors, or long cable runs, this isolation is not optional; it is the primary defense against conducted EMI that would otherwise corrupt the CPU’s internal data bus.
Each output channel incorporates a current-limiting resistor network in series with the optocoupler LED, ensuring that the drive current remains within the LED’s rated forward current regardless of minor supply voltage fluctuations within the 20.4–28.8 V DC tolerance band. This design prevents premature optocoupler degradation — a common failure mode in modules that lack this protection — and extends the module’s service life in continuous-duty applications.
The short-circuit detection circuit monitors the voltage drop across the output transistor’s sense resistor. When the load current exceeds the threshold (typically 1.5× rated current), the protection circuit disables the affected channel within microseconds and sets the corresponding diagnostic bit in the module’s status register. The CPU reads this status via the diagnostic interrupt (OB 82) without requiring a full program scan, which means fault response latency is bounded by the interrupt processing time rather than the scan cycle time — a critical distinction in safety-relevant applications.
The module’s EMC design follows Siemens’ standard practice for SIMATIC S7-300 hardware: the PCB layout uses a ground plane layer to minimize radiated emissions from the backplane bus signals, and all field-side signal lines are routed with controlled impedance to reduce crosstalk between adjacent output channels. The front connector’s cable shield clamp provides a low-impedance path to the rack’s protective earth (PE), ensuring that shielded cables connected to the module contribute to the overall system’s EMC performance rather than acting as antennas.
System Integration Benefits
- Deterministic scan-cycle integration: Output data is written to the process image output table (PAA) at the start of each CPU scan cycle, ensuring that all output channels are updated simultaneously at a defined point in the program execution — eliminating the timing ambiguity associated with asynchronous output updates.
- Channel-level diagnostic transparency: Each of the 16 output channels reports its status (active, short-circuit, supply fault) independently to the CPU via data records DS 0 and DS 1, enabling the application program to implement channel-specific fault handling without relying on external monitoring hardware.
- Hot-swap compatible front connector: The 20-pin front connector can be removed and reinserted under power without damaging the module or disrupting adjacent slots, reducing MTTR to under 5 minutes for trained maintenance personnel.
- Parameterization via STEP 7 / TIA Portal: Module behavior — including diagnostic interrupt enable/disable, substitute value on CPU STOP, and output hold/reset on fault — is configured entirely in software without hardware jumpers, reducing commissioning errors and enabling remote reconfiguration.
- Substitute value behavior on CPU STOP: The module can be parameterized to hold the last output state or reset all outputs to 0 when the CPU transitions to STOP mode, providing a configurable fail-safe behavior aligned with the machine’s safety requirements.
- Compatibility with ET 200M distributed I/O: The 715-083930-001 is mechanically and electrically compatible with the ET 200M distributed I/O station when used with an IM 153-x interface module, enabling deployment in remote I/O cabinets connected via PROFIBUS DP — extending the control system’s physical reach without additional engineering effort.
- Consistent electrical characteristics across the S7-300 range: The module’s 24 V DC / 0.5 A per channel specification aligns with the standard field device voltage used across Siemens’ SIMATIC ecosystem, simplifying power supply sizing and cable selection for system engineers.
- Reduced wiring density: With 16 output channels in a 40 mm wide housing, the 715-083930-001 achieves a channel density of 0.4 channels per millimeter of rack width, minimizing cabinet footprint in space-constrained installations such as machine tool control panels or skid-mounted process equipment.
Quality Assurance & Global Logistics
Every Siemens 715-083930-001 unit supplied by siemensplc.com is sourced through verified supply channels and undergoes incoming inspection prior to dispatch. Inspection procedures include visual examination of the housing, connector pins, and labeling; functional verification of the backplane bus connector continuity; and cross-referencing of the module’s firmware version label against Siemens’ published hardware revision records. Units that do not pass inspection are quarantined and not offered for sale.
Our warehouse is located in Xiamen, China — a major international logistics hub with direct access to Xiamen Gaoqi International Airport (XMN) and Xiamen Port, one of China’s top-ten container ports by throughput. This geographic position enables us to offer competitive transit times to destinations across Southeast Asia (2–4 business days), Europe (5–8 business days via air freight), North America (5–7 business days), and the Middle East (3–5 business days). All shipments are dispatched with full tracking and commercial invoice documentation compliant with the destination country’s customs requirements.
For orders requiring expedited delivery, we maintain relationships with DHL Express, FedEx International Priority, and UPS Worldwide Express, with same-day dispatch available for orders confirmed before 14:00 CST. Bulk orders and long-term supply agreements are supported with scheduled delivery programs to align with customers’ planned maintenance windows.
All products are covered by a 12-month warranty from the date of shipment. Warranty claims are processed within 5 business days of receipt of the returned unit, with replacement or credit issued upon confirmation of the defect. Our technical team is available to assist with installation, commissioning, and fault diagnosis throughout the warranty period at no additional charge.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.