Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6ES7314-1AG14-0AB0 CPU 314 PLC Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES7314-1AG14-0AB0.

Exact part6ES7314-1AG14-0AB0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6ES7314-1AG14-0AB0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6ES7314-1AG14-0AB0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6ES7314-1AG14-0AB0
Product Type
PLC CPU Module
Series / Family
SIMATIC
Country of Origin
DE
Catalog Category
PLCs & Controllers
Operating Temp.
0 °C to +60 °C
Humidity
10–95% RH, non-condensing
Model confirmed for inquiry 6ES7314-1AG14-0AB0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6ES7314-1AG14-0AB0 CPU 314 — Stop the Clock on Your Downtime

Every minute your S7-300 rack sits dark, the losses compound. A failed CPU 314 doesn’t wait for procurement cycles — and neither do we. The Siemens 6ES7314-1AG14-0AB0 is physically on our shelf in Xiamen, tested, packed, and ready to clear customs before your maintenance team finishes the incident report. Whether you’re running an automotive press line, a chemical batch reactor, or a water treatment station, this is the module that gets you back to green.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Order No. (MLFB) 6ES7314-1AG14-0AB0 ✔ Ready to Ship
Product Family SIMATIC S7-300
CPU Type CPU 314
Work Memory 192 KB (integrated)
Load Memory Micro SD card (up to 8 MB)
Bit Processing Speed 0.1 µs / instruction
Word Processing Speed 0.2 µs / instruction
Floating Point Speed 3.0 µs / instruction
Max Digital I/O 1,024 DI / 1,024 DO
Max Analog I/O 256 AI / 256 AO
Communication MPI (187.5 kbps – 12 Mbps)
Timers / Counters 256 / 256
Supply Voltage DC 24 V (backplane bus)
Current Draw (5 V bus) 1.2 A
Operating Temperature 0 °C to +60 °C
Storage Temperature -40 °C to +70 °C
Humidity 10–95% RH, non-condensing
Protection Rating IP20
Dimensions (W×H×D) 40 × 125 × 130 mm
Weight ~280 g
Firmware Revision V3.3.x (AG14)
Programming Software STEP 7 V5.4 SP5+ / TIA Portal (legacy mode)
Certifications CE, UL, cULus, ATEX Zone 2
Origin Germany

Troubleshooting & Replacement Tips

Swapping a CPU 314 under pressure is where most field mistakes happen. Here’s what actually matters on the bench:

1. Micro SD Card — Don’t Forget It
The 6ES7314-1AG14-0AB0 stores its user program on the Micro SD card, not in internal flash. When you pull the failed CPU, remove the SD card first and transfer it to the replacement unit. If the card is corrupted or missing, you’ll need to reload the program from your STEP 7 project archive via MPI. No card = no program on power-up. This is the single most common field error on CPU 314 swaps.

2. Firmware Revision Matching
The AG14 suffix is not cosmetic — it denotes a specific hardware and firmware revision. Do not mix AG13 and AG14 units in a redundant or multi-CPU architecture. The AG14 firmware baseline (V3.3.x) resolves several errata present in AG13, including edge cases in OB85 handling during partial I/O failure. Confirm the firmware version via STEP 7 → PLC → Module Information before declaring the swap complete.

3. MPI Address Configuration
The CPU 314 does not use DIP switches for MPI addressing — the node address is set in the hardware configuration (HW Config) and stored on the Micro SD card. If you’re loading a fresh card, the default MPI address is 2. Verify this matches your network topology before connecting to the MPI segment, or you’ll create an address conflict that takes the entire MPI bus down.

4. Common Fault Codes to Know

  • SF LED solid red + BF LED off: Internal CPU fault or corrupted program block. Pull the SD card, reformat, reload program from STEP 7 archive.
  • SF + BF both solid red: Hardware configuration mismatch — the loaded HW Config doesn’t match the physical rack. Re-download HW Config from STEP 7 after confirming all module order numbers.
  • STOP mode immediately after RUN command: Check OB1 for missing called FBs/FCs, or verify that all I/O modules referenced in the program are physically present and responding.
  • Diagnostic buffer event 0x2521: Rack failure or power supply undervoltage. Check PS 307 output voltage under load before condemning the CPU.
  • 0x2833 — Module removed or not responding: Backplane bus connector not fully seated. Power down, reseat the CPU, check the bus connector locking tab.

5. Battery Consideration
The CPU 314 does not require a battery for program retention (SD card handles that), but retentive memory areas (M bits, DB retain flags) are lost on power cycle without the optional battery 6ES7971-1AA00-0AA0. If your process relies on retentive data across power outages, install the battery before commissioning.

6. Slot Position
The CPU must occupy Slot 2 on the S7-300 rack. Slot 1 is reserved for the power supply. Placing any signal module in Slot 2 or Slot 3 (interface module position) will prevent the system from initializing.

Reliability in Harsh Conditions

The S7-300 platform was engineered for environments that would destroy consumer-grade electronics within weeks. The 6ES7314-1AG14-0AB0 carries ATEX Zone 2 certification, meaning it has been validated for use in areas where explosive gas atmospheres may occasionally be present — a standard requirement in petrochemical and offshore applications.

Vibration resistance is rated to IEC 60068-2-6: 10–58 Hz at 0.075 mm amplitude, 58–500 Hz at 1 g. In practice, this covers the vibration profiles of most industrial machinery, including press lines, compressor rooms, and rail-mounted control cabinets. The conformal-coated PCB variant (where applicable) adds protection against condensation and corrosive atmospheres.

Thermal performance is validated across 0 °C to +60 °C operating range with storage down to -40 °C — relevant for outdoor cabinet installations in northern climates or cold-storage facilities where the panel may sit unpowered through winter shutdowns. The unit draws only 4 W typical, keeping cabinet thermal load manageable even in poorly ventilated enclosures.

All units we ship have been stored in a climate-controlled warehouse maintained at 18–25 °C with relative humidity below 60%. Each unit undergoes incoming inspection: visual check of housing and connector pins, power-on RUN/STOP cycle test, MPI communication handshake verification, and firmware version confirmation against Siemens product lifecycle records. Anti-static packaging with humidity indicator card is standard on every shipment.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian, China — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Here’s how a typical urgent order moves:

  • Order confirmed before 14:00 CST: Same-day dispatch. Export documentation (commercial invoice, packing list, certificate of origin) prepared in parallel with packing.
  • DHL Express / FedEx International Priority: Transit times of 2–4 business days to most of Europe, Southeast Asia, the Middle East, and North America. We select the carrier based on your destination and declared urgency.
  • HS Code: 8537.10 (boards, panels, consoles for electric control). Pre-classified to avoid customs clearance delays at destination.
  • Tracking: AWB number provided within 2 hours of dispatch. We monitor shipments proactively and flag any customs holds immediately.
  • Documentation: Full export paperwork included. For customers requiring FORM E (ASEAN), CO (Chamber of Commerce), or specific country-of-origin declarations, notify us at order placement.

For plant shutdowns or production-critical emergencies, contact us directly on WhatsApp for real-time stock confirmation and same-day shipping commitment before placing the order.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.