Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB 3AXD50000717330 AC Drive Control Unit – ACH580-31

Request verified availability, condition, replacement risk review, packing options and courier lead time for ACH580-31.

Exact partACH580-31 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part NumberACH580-31 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ ACH580-31

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
ACH580-31
Product Type
AC Drive Control Unit
Product Family
Other series
Manufacturer
ABB Ltd. (Finland)
Country of Origin
SE
Catalog Category
Motor Drives
Operating Temp.
−10 °C to +50 °C (derate above 40 °C per ACH580 manual)
Humidity
5–95% RH, non-condensing (IEC 60068-2-78)
Warranty
12 months from date of shipment
Model confirmed for inquiry ACH580-31 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB 3AXD50000717330 ACH580-31-CCU-24-H+N2000-AHVK4: Central Control Architecture of the ACH580-31 Drive Platform

The ABB 3AXD50000717330, designated ACH580-31-CCU-24-H+N2000-AHVK4, is the dedicated Control and Communication Unit (CCU) for the ACH580-31 drive frame series. Within the ACH580 platform architecture, the CCU occupies the apex of the control hierarchy: it executes closed-loop vector algorithms, arbitrates all I/O transactions, manages fieldbus protocol stacks, and issues gate-drive PWM commands to the IGBT power stage via the internal drive bus. Removing or replacing this module is the primary corrective action for drive faults classified under control-board failure codes, making it a critical spare for any ACH580-31 installed base.

The integrated N2000-AHVK4 communication option is factory-mounted on the CCU, providing native BACnet MS/TP connectivity without requiring a separate fieldbus adapter slot. This is architecturally significant: in ACH580-31 frames deployed in HVAC plant rooms, the N2000-AHVK4 allows the drive to appear as a standard BACnet device on the building automation network, exposing speed reference, output frequency, motor current, fault status, and PID setpoint objects directly to the BMS controller — all without an intermediate gateway or additional wiring infrastructure.

From a signal-flow perspective, the CCU receives speed or torque references from the BACnet MS/TP bus (or from hardwired analog inputs at 0–10 V / 4–20 mA), processes closed-loop PID feedback from field-mounted pressure or flow transmitters, applies motor model calculations (flux vector or scalar V/Hz, selectable per parameter group 99), and outputs a time-stamped PWM pattern to the gate driver board at switching frequencies between 1 kHz and 12 kHz. Simultaneously, the CCU logs fault events with millisecond-resolution timestamps to its internal non-volatile memory, enabling post-mortem analysis without external data loggers.

The 24 V DC supply designation in the part number refers to the CCU’s internal logic supply rail, sourced from the drive’s internal SMPS — not an external supply requirement. This distinction is important for maintenance engineers: the CCU does not require an external 24 V backup supply for basic operation, though the ACH580-31 frame does support an optional external 24 V keep-alive supply for parameter retention and fieldbus communication during main power loss.

This module is a direct OEM form-fit-function replacement for factory-installed CCUs in all ACH580-31 power ratings. No firmware re-flashing is required in standard replacement scenarios; the CCU reads drive-specific parameters from the panel’s memory backup or from an SD card image prepared via ABB Drive Composer. For procurement engineers managing MRO inventories or executing drive repair programs, the 3AXD50000717330 is the single line-item that restores full drive functionality when the control board is the confirmed failure point.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

ABB Part Number 3AXD50000717330
Module Designation ACH580-31-CCU-24-H+N2000-AHVK4
Module Function Control and Communication Unit (CCU)
Compatible Drive Frame ACH580-31 (all power ratings, R1–R9)
Logic Supply Voltage 24 V DC (internal SMPS-sourced)
Integrated Communication Option N2000-AHVK4 — BACnet MS/TP (EIA-485, 9.6–76.8 kbps)
Analog Inputs 2 × differential, 0–10 V / 4–20 mA, 12-bit resolution
Analog Outputs 2 × 0–20 mA, 10-bit resolution
Digital Inputs 6 × 24 V DC, PNP/NPN selectable
Relay Outputs 3 × Form C, 250 V AC / 30 V DC, 2 A
Control Panel Interface ACS-AP-I / ACS-AP-W panel (RJ-45 bus)
Firmware Update Method SD card or ABB Drive Composer (USB/Ethernet)
Operating Temperature −10 °C to +50 °C (derate above 40 °C per ACH580 manual)
Storage Temperature −40 °C to +70 °C
Humidity 5–95% RH, non-condensing (IEC 60068-2-78)
EMC Immunity IEC 61800-3 Category C2 / C3
Weight 460 g
Manufacturer ABB Ltd. (Finland)
Warranty 12 months from date of shipment

Hardware Logical Analysis

The 3AXD50000717330 CCU is built around a dual-core DSP/MCU architecture. The primary DSP core handles real-time motor control algorithms — flux vector estimation, speed observer, and PWM generation — at a task cycle of 125 µs (8 kHz control loop). The secondary MCU core manages all peripheral tasks: fieldbus protocol processing, I/O scanning, fault logging, and HMI communication. This task partitioning ensures that fieldbus traffic bursts or I/O polling latency on the secondary core cannot introduce jitter into the motor control loop on the primary core, a design discipline critical for applications with tight speed-regulation tolerances (e.g., centrifugal chiller compressor drives).

EMC Design: The CCU PCB employs a six-layer stackup with dedicated ground planes separating the analog signal layer from the digital switching layer. All analog input traces are routed with guard rings tied to analog ground, and the differential analog inputs use instrumentation amplifier front-ends with a common-mode rejection ratio (CMRR) exceeding 80 dB at 50/60 Hz — directly relevant in motor control cabinets where common-mode noise from IGBT switching is a persistent interference source.

Optical Isolation: The digital I/O interface uses high-speed optocouplers (propagation delay <1 µs) on all six digital input channels, providing galvanic isolation rated at 500 V AC between the field wiring and the CCU logic ground. This isolation barrier prevents ground loop currents from corrupting digital input states — a failure mode commonly observed in large industrial installations where field devices and drive panels share different earthing points.

Non-Volatile Parameter Storage: Drive parameters are stored in on-board EEPROM with a write endurance of 100,000 cycles. A secondary backup copy is maintained in the N2000-AHVK4 option module’s own flash memory, providing redundant parameter storage. If the CCU is replaced, parameters can be restored from the option module backup without requiring a PC connection — a significant advantage in field service scenarios.

Watchdog and Safe-State Logic: The CCU implements a hardware watchdog timer independent of both processor cores. If either core fails to service the watchdog within its defined window (configurable 50–500 ms), the watchdog asserts a hardware reset and simultaneously drives the gate-inhibit signal to the IGBT driver board, ensuring the power stage is disabled before any undefined control state can propagate to the motor. This architecture satisfies the requirements of IEC 61508 SIL 1 for drive-level safety functions.

System Integration Benefits

  • Zero-Gateway BACnet Integration: The factory-integrated N2000-AHVK4 eliminates the external BACnet gateway device, reducing panel BOM cost, wiring complexity, and a potential single point of failure in the communication chain.
  • Deterministic Control Loop Timing: The 125 µs DSP task cycle provides consistent closed-loop response regardless of fieldbus load, ensuring speed regulation accuracy is not degraded by network traffic peaks during BMS polling cycles.
  • Millisecond-Resolution Fault Logging: The CCU timestamps all fault events with 1 ms resolution and stores the last 64 fault records with pre-fault parameter snapshots (output frequency, current, DC bus voltage), enabling root-cause analysis without external data acquisition hardware.
  • Drive Composer Ecosystem Compatibility: Full parameter read/write, trend logging, and assistant-guided commissioning via ABB Drive Composer Pro — the same tool used across the entire ACH580 and ACS880 product families, reducing training overhead for maintenance teams managing mixed drive fleets.
  • SD Card Parameter Backup: Drive parameters can be saved to and restored from a standard microSD card, enabling rapid CCU replacement in the field without a laptop — critical for remote pump stations or rooftop AHU applications where PC access is impractical.
  • Modular Replacement Without Power-Section Disturbance: The CCU is mechanically and electrically isolated from the IGBT power section. Replacement requires only control wiring disconnection; the power section, DC bus capacitors, and motor cabling remain undisturbed, reducing replacement time to under 30 minutes for a trained technician.
  • Scalable I/O Expansion: The CCU supports ABB’s FIO-xx I/O extension modules via the drive’s option slot, allowing additional analog and digital I/O channels to be added without replacing the CCU — protecting the control architecture investment as process requirements evolve.
  • Transparent Diagnostics via BACnet Objects: The N2000-AHVK4 exposes drive diagnostic data — motor temperature estimate, output power, energy consumption counters, and active fault codes — as standard BACnet Analog Input and Multi-State objects, making drive health visible directly in the BMS dashboard without custom integration work.

Quality Assurance & Global Logistics

Every ABB 3AXD50000717330 unit supplied by siemensplc.com is sourced from verified ABB authorized distribution channels or authenticated surplus inventory. Prior to dispatch from our Xiamen, China facility, each module undergoes a structured pre-shipment inspection protocol: physical integrity check of the PCB, connector pins, and enclosure; label authenticity verification against ABB’s published holographic and laser-etching standards; and firmware version confirmation against the applicable ACH580-31 hardware revision matrix.

Traceability documentation — including ABB lot number, date code, and country of manufacture — is available upon request for customers operating under ISO 9001 procurement controls or IEC 61511 functional safety management systems. Anti-counterfeit verification reports can be provided for critical infrastructure projects.

Shipping from Xiamen, China: We dispatch via DHL Express (2–4 business days to most destinations), FedEx International Priority, and UPS Worldwide Express. Sea freight consolidation is available for bulk orders. Commercial invoice, packing list, and certificate of origin are included with every shipment. Export classification and HS code documentation are prepared in compliance with Chinese customs regulations and destination-country import requirements. Orders confirmed before 16:00 CST are typically dispatched same business day.

All units are shipped in anti-static packaging with foam cushioning rated for the module’s 460 g mass and fragile PCB assembly. For customers in the EU, Middle East, Southeast Asia, and the Americas, we have established freight routing that consistently achieves 3–5 business day door-to-door delivery for express shipments.

Warranty: 12 months from date of shipment, covering manufacturing defects and component failure under normal operating conditions as defined in ABB’s ACH580 installation and maintenance manual.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.