Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
ABB In Stock OK

ABB CINT-45X1 Drive Interface Board

Request verified availability, condition, replacement risk review, packing options and courier lead time for CINT-45X1.

Exact partCINT-45X1 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandABB Part NumberCINT-45X1 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ CINT-45X1

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
ABB
Primary Part Number
CINT-45X1
Product Type
Drive Interface Board
Series / Family
Interface Board AINT Series
Manufacturer
ABB
Country of Origin
SE
Catalog Category
Motor Drives
Operating Temp.
0 °C to +55 °C (ambient, drive cabinet)
Humidity
5–95% RH, non-condensing
Warranty
12 months from dispatch
Model confirmed for inquiry CINT-45X1 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

ABB CINT-45X1 Drive Interface Board — Stop the Clock on Your Downtime, Ship Today

When an ABB AINT series drive trips offline and fault diagnostics point to the interface board, every hour without a replacement is a direct financial loss. On a paper machine running at 1,200 m/min, a rolling mill mid-campaign, or a marine propulsion system at sea, there is no acceptable delay. The ABB CINT-45X1 is the communication backbone of the AINT drive platform — it handles fieldbus signal routing, I/O arbitration, and control panel connectivity simultaneously. When it fails, the drive is blind, deaf, and mute to the automation network. We stock it. We ship it today.

The CINT-45X1 sits on the AINT drive’s control board stack as the primary interface layer between the drive’s internal DSP logic and the external automation bus. It manages the physical-layer handshake for PROFIBUS-DP, DeviceNet, or Modbus RTU depending on the adapter fitted, while simultaneously processing the 24 VDC digital I/O signals that govern start/stop, fault reset, and speed reference selection. Loss of this board does not produce a graceful degradation — it produces a hard fault, typically logged as FF (Communication Fault) or A-81 (Panel Loss) in the drive’s event log, with no recovery path until the board is replaced. Firmware mismatch between a replacement CINT-45X1 and the host drive’s RMIO board is the single most common commissioning error post-replacement — we address this in the troubleshooting section below.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number CINT-45X1
Manufacturer ABB
Product Series AINT (AC Drive Platform)
Module Function Drive Interface Board — Fieldbus, I/O, Panel Communication
Supported Fieldbus PROFIBUS-DP, DeviceNet, Modbus RTU (adapter-dependent)
Digital I/O Multiple DI/DO channels, 24 VDC logic level
Control Voltage 24 VDC (supplied from AINT drive internal SMPS)
Operating Temperature 0 °C to +55 °C (ambient, drive cabinet)
Storage Temperature -40 °C to +70 °C
Humidity 5–95% RH, non-condensing
Vibration Resistance IEC 60068-2-6 compliant
Warranty 12 months from dispatch
Stock Status ✔ Ready to Ship — Xiamen, China
Condition New / Tested-Refurbished (specify at inquiry)
Origin Germany (ABB manufacturing)

Troubleshooting & Replacement Tips

Fault Codes That Point to CINT-45X1 Failure

  • FF / Communication Fault: Drive loses fieldbus node presence. PLC reports device timeout. Root cause is frequently CINT-45X1 internal oscillator failure or corrupted firmware on the interface layer.
  • A-81 / Panel Loss: Control panel goes blank mid-operation. If the panel cable and connector test clean, the CINT-45X1’s panel port logic has failed.
  • I/O Mismatch Alarm: DI signals present at terminal block but not recognized by drive logic — indicates CINT-45X1 I/O buffer failure, often caused by transient overvoltage on the 24 VDC supply rail.
  • Intermittent Drive Trips at High Load: Thermal cycling causes micro-fractures in CINT-45X1 solder joints on the fieldbus transceiver IC. Fault clears on cool-down, returns under load. Replace the board — reflow soldering is not a reliable field fix.

Step-by-Step Replacement Procedure

  1. Record drive parameters before power-down. Use the ABB DriveWindow or CDP control panel to upload the full parameter set to a PC or panel memory. A CINT-45X1 swap does not erase RMIO parameters, but confirm this against your drive firmware version.
  2. Isolate and lock out the drive. Follow your site LOTO procedure. Verify DC bus voltage has discharged below 50 VDC before opening the drive cabinet — use a calibrated meter, not the drive’s own display.
  3. Document connector positions. Photograph all ribbon cables and fieldbus connectors on the existing CINT-45X1 before removal. Connector X1 (panel), X2 (fieldbus adapter), and the I/O ribbon to the RMIO board must be reinstalled in identical orientation.
  4. Check firmware compatibility. The replacement CINT-45X1 must carry firmware compatible with the RMIO board version in your drive. Mismatched firmware produces a BOARD INCOMPATIBLE fault on first power-up. Confirm the firmware version printed on the CINT-45X1 label matches or is approved for your RMIO revision. Contact us — we can match firmware versions at dispatch.
  5. Verify DIP switch settings. Some CINT-45X1 variants carry DIP switches for node address or baud rate selection. Photograph the original board’s switch positions before removal and replicate exactly on the replacement.
  6. Power up in local control first. Before reconnecting fieldbus, run the drive in local panel control to confirm basic I/O and panel communication are functional. Only then reconnect the fieldbus adapter and restore remote control.
  7. Restore and verify parameters. Download the saved parameter set and verify critical parameters: motor data, speed limits, and fieldbus node address. Run a no-load test before returning to production.

Reliability in Harsh Conditions

The CINT-45X1 is not a commercial-grade PCB assembly. ABB designs AINT series interface boards to operate continuously in environments that would destroy standard industrial electronics within months. The board’s conformal coating — applied to IPC-CC-830B standard — seals the PCB surface against moisture ingress, condensation, and airborne contaminants including metallic dust from grinding operations and sulfur compounds in pulp mill atmospheres.

The fieldbus transceiver ICs are mounted with thermal interface material to the board’s copper pour ground plane, providing a low-resistance thermal path that keeps junction temperatures within specification even when ambient cabinet temperatures reach 50 °C during summer production peaks. The I/O buffer ICs incorporate TVS diode arrays on every input line, rated to clamp transients up to ±600 V peak — a critical protection mechanism in facilities where motor cable runs exceed 100 m and capacitive coupling generates significant common-mode noise on the 24 VDC I/O wiring.

Vibration performance is validated to IEC 60068-2-6: 5–150 Hz sweep, 1 g acceleration, 10 cycles per axis. This covers the resonance frequencies generated by large motor frames, compressor skids, and ship hull vibration in marine installations. The board-to-board connectors use gold-plated contacts with positive retention latches — not friction-fit — ensuring signal continuity is maintained under sustained vibration that would cause intermittent contact in lower-grade assemblies.

Global Express Logistics

Our dispatch hub is located in Xiamen, China — a major international freight gateway with direct DHL, FedEx, and UPS express lanes to Europe, the Americas, Southeast Asia, the Middle East, and Australia. For urgent replacement orders, we operate a same-day dispatch cut-off of 16:00 CST for orders confirmed with payment before that time.

  • Europe (DE, NL, FR, UK, SE): DHL Express — 3–5 business days door-to-door. Customs clearance documentation provided as standard.
  • North America (US, CA): FedEx International Priority — 3–5 business days. FDA/CBP compliant commercial invoice and HS code documentation included.
  • Southeast Asia (SG, MY, TH, ID): DHL Express — 2–4 business days. Regional hub routing via Singapore for fastest last-mile delivery.
  • Middle East (AE, SA, QA): FedEx or DHL — 4–6 business days. Legalized commercial invoice available for customs clearance in GCC countries.
  • Australia & New Zealand: DHL Express — 4–6 business days.
  • All shipments: Full tracking number provided within 2 hours of dispatch. ESD-safe anti-static bag + foam-lined carton packaging as standard. Export packing list and commercial invoice included.

For shipments to remote sites, offshore platforms, or free-trade zones, contact us directly — we have experience with bonded warehouse routing, agent-assisted customs clearance, and freight-on-board (FOB) Xiamen terms for large orders.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.