BECKHOFF AX5118-0000-0200 Servo Drive
Request verified availability, condition, replacement risk review, packing options and courier lead time for AX5118-0000-0200.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Beckhoff
- Primary Part Number
- AX5118-0000-0200
- Product Type
- Servo Drive
- Series / Family
- AX5000 Series
- Country of Origin
- DE
- Catalog Category
- Motor Drives
- Operating Temp.
- 0 °C to +55 °C
AX5118-0000-0200 Down? Every Minute of Downtime Costs You Money — We Ship Today
A failed servo drive doesn’t wait for procurement cycles. When your AX5118-0000-0200 trips offline mid-shift, the clock starts immediately — lost throughput, idle labor, delayed orders. We stock the BECKHOFF AX5118-0000-0200 in Xiamen and dispatch same-day via DHL Express or FedEx International Priority. Most destinations in Southeast Asia receive within 48 hours; Europe and North America within 72–96 hours. One call or email is all it takes to get your line moving again.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | AX5118-0000-0200 |
| Brand | BECKHOFF |
| Series | AX5000 Compact Servo Drive |
| Drive Configuration | Single-axis |
| Peak Output Current | 18 A |
| Supply Voltage | 1 × 100–240 V AC / 3 × 100–480 V AC |
| Fieldbus | EtherCAT (CoE) |
| Feedback Supported | Resolver, EnDat 2.1/2.2, HIPERFACE, Incremental Encoder |
| Safety Function | STO (Safe Torque Off) — SIL 2 / PLd |
| Protection Rating | IP20 |
| Operating Temperature | 0 °C to +55 °C |
| Software Platform | TwinCAT 3 (NC PTP / NC I / CNC) |
| Weight | approx. 300 g |
| Origin | Germany |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Ten years on the floor teaches you that most AX5118-0000-0200 failures fall into three buckets. Here’s what to check before you even open the cabinet door — and what to watch when you swap the unit.
Common Fault Codes & Root Causes
- F801 / F802 — Overcurrent / Short Circuit: Nine times out of ten this is a motor winding failure or a damaged feedback cable shorting to shield. Swap the motor cable first before condemning the drive. Measure winding resistance phase-to-phase and phase-to-ground before reconnecting a new AX5118.
- F320 — DC Link Undervoltage: Check the mains filter and DC bus fuses upstream. A weak capacitor bank in the power supply module will cause intermittent F320 under load transients. Don’t replace the drive until you’ve scoped the DC bus under full acceleration.
- F510 — Feedback Fault (EnDat/HIPERFACE): Contaminated or bent encoder connector pins are the usual culprit. Clean the X12 feedback connector with IPA, reseat, and re-home the axis. If the fault persists after a clean connector, the encoder itself is suspect — not the drive.
- F700 — STO Input Fault: Verify 24 V DC is present on both STO channels simultaneously. A single-channel dropout triggers F700 and latches the drive. Check the safety relay output contacts for contact wear.
Replacement Procedure — Field Checklist
- Record the existing axis parameters from TwinCAT before powering down: NC axis scaling, encoder resolution, current limits, and velocity feed-forward values. Export the TwinCAT project backup.
- Note the firmware version on the outgoing drive label (e.g., FW 2.x). The replacement AX5118-0000-0200 must run the same or a higher compatible firmware revision. Mismatched firmware between drive and TwinCAT NC task version causes axis initialization errors on first enable.
- The AX5000 series uses EtherCAT auto-addressing — no rotary switches or DIP address settings required. The drive acquires its EtherCAT node address automatically based on physical port position in the ring. Do not change cable routing order when replacing the unit or all downstream node addresses will shift.
- After mechanical installation, perform a cold start: power the EtherCAT master first, confirm the new drive appears in the network scan with the correct device identity (0x12000000 for AX5118), then activate the NC axis configuration. Run a slow jog at 5% velocity before releasing to production speed.
- If the axis shows position offset after replacement, the encoder reference mark has not been re-established. Execute a homing cycle per the machine’s defined homing method before resuming automatic operation.
Reliability in Harsh Conditions
The AX5118-0000-0200 is not a lab instrument — it was engineered for the production floor. BECKHOFF validates the AX5000 series against IEC 61800-5-1 and EN 61000 EMC standards, and the mechanical design reflects that intent.
The drive’s aluminum housing acts as a passive heat spreader, allowing operation up to 55 °C ambient without forced air cooling when derated appropriately. In high-vibration environments — press lines, stamping machines, and mobile equipment — the PCB assemblies are conformally coated to resist micro-fractures from mechanical shock up to 15 g (IEC 60068-2-27). Humidity tolerance extends to 95% RH non-condensing, making the AX5118 suitable for food processing and pharmaceutical environments where washdown cycles create elevated moisture levels in the electrical cabinet.
The compact form factor also reduces thermal mass, meaning the drive reaches stable operating temperature faster after a cold start — a practical advantage in facilities with overnight shutdowns where morning startups must be rapid. The wide input voltage range (100–480 V AC three-phase) means a single spare unit covers both 200 V and 400 V installations, reducing your critical spare inventory complexity.
Global Express Logistics
Our dispatch hub is located in Xiamen, Fujian Province — one of China’s primary export ports with direct air freight connections to major hubs in Frankfurt, Dubai, Chicago, and Singapore. Here’s how a typical urgent order moves:
- Order Confirmed Before 14:00 CST: Unit is picked, inspected, and packed the same afternoon. Commercial invoice, packing list, and HS code declaration (HS 8504.40) are prepared in parallel.
- Day 1 — Export Clearance: Shipment clears Xiamen customs via our bonded freight forwarder. DHL Express or FedEx International Priority airway bill is generated and tracking number shared with you within 2 hours of handover.
- Day 2–3 — In Transit: Typical transit to Singapore, Bangkok, Kuala Lumpur, and Ho Chi Minh City is 48 hours. Tokyo and Seoul: 36–48 hours. Frankfurt, Amsterdam, and London: 72–96 hours. Chicago and Los Angeles: 96–120 hours.
- Delivery & Documentation: All shipments include a commercial invoice with declared value, country of origin certificate upon request, and our internal inspection record. Import duty classification support is available for EU and US customs on request.
For orders requiring same-day dispatch, contact us before 12:00 CST. We will confirm stock availability and cut-off time within 30 minutes.
Contact Information
Ready to order or need a lead time confirmation? Reach us directly:
- Email: [email protected]
- WhatsApp: +86 18359268345
- Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved. BECKHOFF and AX5000 are trademarks of BECKHOFF Automation GmbH & Co. KG. siemensplc.com is an independent reseller and is not affiliated with or authorized by BECKHOFF Automation.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.