330101-00-16-10-02-05 — Stop the Clock on Your Downtime. Ship Today.
Every hour a turbine, compressor, or critical pump sits idle because of a failed proximity probe, you’re bleeding money. On a mid-size gas turbine train, unplanned downtime can cost $50,000–$200,000 per day in lost production, emergency labor, and contractual penalties. The Bently Nevada 330101-00-16-10-02-05 is a 5 mm eddy current proximity probe from the 3300 XL Transducer System — and we have it on the shelf in Xiamen, ready to clear customs and land on your site within 48–72 hours via DHL Express or FedEx International Priority.
This is not a catalog listing. This is a field-ready unit, inspected, verified, and packed for immediate dispatch. If your monitoring rack is throwing a Not OK relay or your DCS is flagging a transducer fault, stop reading datasheets and start the procurement process now.
⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 330101-00-16-10-02-05 ✅ Ready to Ship |
| Brand | Bently Nevada (Baker Hughes) |
| Series | 3300 XL Proximity Transducer System |
| Probe Tip Diameter | 5 mm (0.197 in) |
| Integral Cable Length | 16 inches (406 mm), armored |
| Thread | M10 × 1 metric |
| Connector | 10-32 coaxial (standard BN) |
| Measurement Principle | Eddy current, non-contact |
| Linear Range | 0.25 – 2.25 mm (10 – 90 mil) |
| Sensitivity | 7.87 V/mm (200 mV/mil) nominal |
| Frequency Response | DC – 10,000 Hz (–3 dB) |
| Supply Voltage | –24 VDC via Proximitor® driver |
| Output Signal | –2 to –18 VDC (gap-proportional) |
| Operating Temperature | –35°C to +177°C |
| Target Material (Standard) | AISI 4140 steel |
| Ingress Protection | IP67 |
| Compatible Proximitor® | 330180 series (3300 XL 8mm driver) |
| Certifications | CE, ATEX, IECEx |
| Weight | ~220 g |
| Origin | United States |
| Stock Status | ✅ In Stock — Ships within 24 hrs of PO confirmation |
Troubleshooting & Replacement Tips
After ten years of field work across refineries, LNG terminals, and power stations, here are the failure modes and replacement pitfalls that catch engineers off guard with the 330101 series:
1. Confirm the fault is the probe — not the extension cable or Proximitor®
The 3300 XL system is a three-component chain. Before condemning the probe, disconnect the extension cable at the Proximitor® input and measure the driver output voltage with a calibrated DMM. A healthy probe+cable combination on a 5 mm gap to AISI 4140 should read approximately –10.5 VDC. If the output is rail-high (near –2 V) or rail-low (near –18 V) with no shaft movement, the fault is almost certainly in the probe tip or the integral cable — not the driver. If the output is erratic or noisy, suspect the extension cable connector or the Proximitor® oscillator circuit first.
2. Total cable length is non-negotiable
The 330101-00-16-10-02-05 has a 16-inch (406 mm) integral cable. The calibrated system length — probe integral cable + extension cable — must equal the factory-calibrated total (typically 5 m or 9 m). Swapping in a probe with a different integral cable length without adjusting the extension cable will shift your sensitivity curve and introduce a DC offset error. Your vibration readings will be wrong, and your trip setpoints will be miscalibrated. Always verify the extension cable part number before ordering.
3. Gap setting after installation
After threading the probe into the bracket, set the initial gap to the midpoint of the linear range: 1.0–1.25 mm (40–50 mil). Use a calibrated gap tool or a feeler gauge on a static shaft. Lock the jam nut to the torque specified in the BN installation manual (typically 20–25 N·m for M10). Do not rely on the output voltage alone for initial gap setting — always verify mechanically first, then confirm electrically.
4. Target material mismatch
The 330101 series is factory-calibrated for AISI 4140 steel. If your shaft journal is Inconel, 17-4 PH stainless, or any non-standard alloy, the sensitivity will deviate — sometimes by 15–25%. If you’re replacing a probe on a non-standard target, request a material-specific calibration certificate or use the BN field calibration procedure (reference document D350672). Skipping this step is the single most common cause of post-replacement vibration reading discrepancies.
5. Common fault codes on 3500 racks
– OK LED off / Not OK relay energized: Probe output outside –2 to –18 VDC window. Check gap, cable continuity, and Proximitor® power supply (–24 VDC rail).
– Buffered output at –24 V: Open circuit in probe or extension cable. Check 10-32 connectors for corrosion or mechanical damage.
– High static reading with no vibration: Probe tip contamination (oil, metallic debris) or target surface damage. Clean tip with IPA; inspect shaft surface for scoring.
– Intermittent OK/Not OK cycling: Loose connector at the Proximitor® input or probe bracket vibrating loose. Re-torque all connections; apply thread-locking compound to bracket fasteners.
6. Firmware and rack compatibility
The 330101-00-16-10-02-05 is hardware-compatible with both the legacy 3300 and the current 3500 monitoring racks. No firmware changes are required on the rack side. However, if you are migrating from a 3300 rack to a 3500 rack simultaneously, verify that the I/O module configuration (channel type: Radial Vibration or Thrust Position) matches your application before energizing.
Reliability in Harsh Conditions
The 3300 XL probe body is machined from 316 stainless steel with a PEEK-encapsulated coil assembly. The integral armored cable uses a stainless braid over a PTFE-insulated coaxial core — not a cost-reduced PVC alternative. This matters in the field.
In steam turbine bearing housings, ambient temperatures routinely exceed 120°C with superimposed vibration at 50–200 Hz. The 330101 series is rated to +177°C continuous, with the armored cable providing mechanical protection against the cyclic bending fatigue that destroys standard instrumentation cables within months. In offshore compressor trains, salt-laden humid air attacks connectors and cable terminations. The IP67 rating on the probe body, combined with the 10-32 coaxial connector’s gold-plated center pin, provides corrosion resistance that keeps the signal path clean through multi-year inspection intervals.
Vibration qualification testing on the 3300 XL series covers 20–2000 Hz swept sine at 20 g, and random vibration per IEC 60068-2-64. The probe bracket mounting is the weak point in most installations — not the probe itself. If you’re seeing recurring probe failures, inspect the bracket weld and fastener torque before condemning the transducer.
Units supplied by siemensplc.com are sourced from verified OEM and authorized distributor channels. Each unit undergoes a pre-shipment inspection covering: physical integrity of the probe tip and cable armor, connector pin condition and continuity check, and visual verification of part number markings against the order. Certificate of Conformance documentation is available on request.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. Here’s how a typical urgent order moves:
Day 0 (Order Confirmation): PO received and confirmed before 14:00 CST. Unit pulled from shelf, inspected, and packed in anti-static foam with rigid outer carton. Commercial invoice, packing list, and HS code declaration (HS 9031.80) prepared for customs clearance.
Day 1 (Dispatch): Shipment handed to DHL Express or FedEx International Priority. Tracking number issued to buyer within 2 hours of pickup. For ATEX-certified units, additional dangerous goods documentation is prepared where required by destination country regulations.
Day 2–4 (Transit): DHL Express from Xiamen typically achieves delivery to Western Europe in 2–3 business days, North America in 3–4 business days, Southeast Asia in 1–2 business days, and Middle East in 2–3 business days. FedEx International Priority timelines are comparable. We select the carrier based on your destination and urgency — just tell us your deadline.
Customs & Import: We provide complete export documentation including HS code classification, country of origin certificate, and commercial invoice at declared value. For buyers in the EU, we can provide EORI-compatible documentation. For buyers in the US, we provide CBP-compliant entry documentation. Duties and import taxes are the buyer’s responsibility unless DDP (Delivered Duty Paid) terms are agreed in advance.
For orders requiring same-day dispatch, contact us via WhatsApp before 12:00 CST. We will confirm stock availability and dispatch timeline within 30 minutes.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.