Emerson KL2101X1-BA1 12P4987X162 CHARM I/O Card – DeltaV Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for KL2101X1-BA1.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Emerson
- Primary Part Number
- KL2101X1-BA1
- Product Type
- CHARM I/O Card
- Series / Family
- DeltaV
- Manufacturer
- Emerson Electric (Fisher-Rosemount Systems)
- Country of Origin
- US
- Catalog Category
- I/O Modules
- Operating Temp.
- 0 °C to +60 °C (32 °F to 140 °F)
- Warranty
- 12 months from date of shipment (genuine new units)
Emerson KL2101X1-BA1 12P4987X162 — CHARM I/O Card for DeltaV Electronic Marshalling Architecture
The Emerson KL2101X1-BA1 (reference number 12P4987X162) is a CHARM I/O Card (CIOC) engineered for deployment within Emerson’s DeltaV distributed control system under the Electronic Marshalling (EM) paradigm. Unlike conventional I/O subsystems that require fixed, pre-engineered signal assignments at the marshalling cabinet level, the CIOC functions as the backplane intelligence layer that arbitrates characterization data from individual CHARM modules — enabling late-binding I/O assignment and dramatically reducing the engineering change order (ECO) burden during plant commissioning and expansion phases.
Each CHARM I/O Card manages a dedicated CHARM carrier baseplate, communicating upstream to the DeltaV controller via the high-speed CIOC backplane bus. The card handles real-time polling of all attached CHARM modules, aggregates channel-level diagnostics, and presents a unified I/O image to the DeltaV controller scan cycle. This architecture decouples field wiring from control logic, allowing instrument engineers and control engineers to work in parallel without interdependency — a measurable reduction in project schedule risk on large-scale greenfield and brownfield installations.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Manufacturer | Emerson Electric (Fisher-Rosemount Systems) |
| Part Number | KL2101X1-BA1 |
| Reference / BOM Number | 12P4987X162 |
| Series | DeltaV CHARM (Characterization Module) |
| Module Classification | CHARM I/O Card (CIOC) |
| I/O Architecture | Electronic Marshalling (EM) — late-binding signal assignment |
| Backplane Interface | DeltaV CIOC proprietary high-speed serial bus |
| Max CHARM Channels per CIOC | Up to 96 channels (carrier-dependent configuration) |
| Supported Signal Types | AI (4–20 mA, HART), AO (4–20 mA, HART), DI (24 VDC), DO (24 VDC), Temperature (RTD/TC) |
| HART Pass-through | Supported per channel via individual CHARM module |
| Operating Temperature | 0 °C to +60 °C (32 °F to 140 °F) |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5% to 95% non-condensing |
| Supply Voltage | 24 VDC (DeltaV system bus powered) |
| Mounting | DeltaV CHARM Carrier Baseplate (8-slot / 16-slot) |
| Compatible DeltaV Versions | v11.3 and above (verify suffix against system release matrix) |
| Compatible Controllers | DeltaV MD, MD Plus, SD, SD Plus |
| Certifications | CE, FM Class I Div 2, ATEX Zone 2 (refer to product datasheet for zone classification) |
| Unit Weight | Approx. 4,460 g (including carrier assembly) |
| Warranty | 12 months from date of shipment (genuine new units) |
Hardware Logical Analysis
The KL2101X1-BA1 CIOC operates as the master node on the CHARM carrier bus, executing a deterministic polling cycle across all populated CHARM slots. Each CHARM module contains its own signal conditioning ASIC and a non-volatile characterization register that stores signal type, range, and HART device descriptor data. The CIOC reads these registers at power-up and on hot-swap insertion events, dynamically reconfiguring its I/O image without requiring a controller download — a capability that directly supports live system maintenance without process interruption.
EMC and Signal Isolation: Each CHARM module incorporates galvanic isolation between the field terminal and the CIOC backplane bus, with isolation barriers rated to withstand transient voltages consistent with IEC 61000-4-5 surge immunity requirements. The CIOC itself employs a multi-layer PCB ground plane architecture that separates analog signal return paths from digital logic ground, suppressing common-mode noise injection from field cable runs that may span hundreds of meters in large process plants. Ferrite bead filtering on the backplane power rails further attenuates high-frequency switching noise originating from adjacent variable-frequency drives or power conversion equipment.
Redundancy and Fault Arbitration: In redundant CIOC configurations, the KL2101X1-BA1 participates in a primary/secondary arbitration protocol over the DeltaV controller backplane. The active CIOC continuously synchronizes its I/O image to the standby unit via a dedicated synchronization channel. On detection of a primary CIOC failure — identified through watchdog timeout or backplane communication loss — the standby unit assumes control within the controller’s configured scan period, with no data loss to the process historian or alarm management layer. This bumpless transfer characteristic is essential for continuous process industries where even a single missed scan can trigger a spurious process trip.
Diagnostic Architecture: The CIOC maintains a per-channel diagnostic register set that tracks open-circuit conditions, out-of-range signals, HART communication failures, and module removal events. These diagnostics are surfaced through DeltaV’s AMS Device Manager and the DeltaV Operate HMI as structured alarm objects, enabling maintenance personnel to identify field device degradation before it escalates to a process deviation. The hardware revision suffix BA1 indicates a specific PCB revision level; operators should cross-reference this against the DeltaV compatibility matrix to confirm firmware alignment with the installed controller version.
System Integration Benefits
- Late-Binding I/O Assignment: Signal type and range are defined at the CHARM module level, not at the marshalling cabinet wiring stage. This allows instrument loop assignments to be finalized after physical installation, compressing the engineering-to-commissioning timeline by eliminating traditional I/O schedule dependencies.
- Hot-Swap Module Replacement: Individual CHARM modules can be removed and replaced under power without interrupting adjacent channels or requiring a controller download. The CIOC automatically re-characterizes the replacement module within one scan cycle, maintaining process continuity during corrective maintenance.
- Deterministic Scan Performance: The CIOC’s polling architecture guarantees a fixed worst-case scan latency across all 96 channels, independent of the number of populated slots. This determinism is a prerequisite for closed-loop control applications where scan jitter directly affects PID tuning stability and process variability.
- HART Multiplexing Without External Hardware: HART pass-through is handled natively at the CHARM module level, eliminating the need for external HART multiplexers or separate HART interface cards. Each channel presents a full HART primary variable and device descriptor to AMS Device Manager, reducing infrastructure cost and cabinet footprint.
- Diagnostic Transparency to HMI Layer: Channel-level fault data is propagated through the DeltaV module database as structured parameters, accessible from DeltaV Operate, DeltaV Diagnostics, and third-party OPC-DA/UA clients. Maintenance teams gain real-time visibility into field device health without requiring physical access to the marshalling cabinet.
- Reduced Marshalling Cabinet Density: Electronic marshalling eliminates the one-to-one correspondence between field terminal blocks and I/O card slots. A single CIOC with a 16-slot carrier replaces multiple conventional I/O cards and their associated junction boxes, reducing cabinet count, cable tray loading, and installation labor on large projects.
- Scalable Expansion Without Rewiring: Adding new field instruments to an existing DeltaV EM system requires only the insertion of a new CHARM module into an available carrier slot. No changes to existing field wiring, no new I/O card procurement, and no controller configuration download are required — a significant operational advantage during plant capacity expansions.
- Lifecycle Alignment with DeltaV Roadmap: As a genuine Emerson component, the KL2101X1-BA1 receives firmware updates and security patches through the standard DeltaV lifecycle support program. This ensures long-term compatibility with DeltaV system upgrades and cybersecurity hardening initiatives, protecting the capital investment in the control system infrastructure.
Quality Assurance & Global Logistics
Every KL2101X1-BA1 unit supplied by siemensplc.com is sourced through verified industrial distribution channels with full manufacturer traceability. Prior to dispatch, each unit undergoes a structured pre-shipment inspection protocol: visual examination for physical damage, connector integrity verification, label and serial number cross-check against manufacturer records, and where applicable, a functional power-on test to confirm backplane communication initialization.
Units are packaged in ESD-protective anti-static bags, enclosed within rigid foam-lined cartons rated for international air freight handling. For shipments to humidity-sensitive destinations, moisture barrier bags with desiccant packs are added as standard. Export documentation — including commercial invoice, packing list, and certificate of conformance — is prepared in compliance with Chinese customs export regulations and the import requirements of the destination country.
Dispatch is handled from our Xiamen, China operations center, with access to major international express carriers including DHL, FedEx, and UPS. Standard transit times to Southeast Asia are 2–4 business days; to Europe and North America, 4–7 business days. For urgent plant shutdown requirements, same-day dispatch on in-stock units is available upon order confirmation before 14:00 CST. All shipments are covered by cargo insurance, and tracking information is provided within 24 hours of dispatch.
A 12-month warranty applies to all genuine new units from the date of shipment. Warranty coverage includes replacement or credit for units confirmed defective under normal operating conditions. Refurbished units, where offered, carry a clearly stated 90-day functional warranty and are individually tested and documented prior to sale.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.