NEGELE DPM-GS-2GW-S Process Display Module – DPM-GS Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for DPM-GS-2GW-S.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- NEGELE
- Primary Part Number
- DPM-GS-2GW-S
- Product Type
- Process Display Module
- Product Family
- Other series
- Manufacturer
- NEGELE Messtechnik GmbH
- Country of Origin
- US
- Catalog Category
- HMI Panels
- Operating Temp.
- -10 °C to +55 °C
- Warranty
- 12 months from date of shipment against manufacturing defects
NEGELE DPM-GS-2GW-S: Precision Process Display Module with Dual Relay Output in Industrial Measurement Loops
The NEGELE DPM-GS-2GW-S is a panel-mount universal process display module engineered for continuous, real-time indication of analog process variables in industrial environments. Manufactured by NEGELE Messtechnik GmbH — a German specialist in hygienic and industrial measurement technology — this unit belongs to the DPM-GS series, which is characterized by its multi-input signal acceptance, dual switching output architecture, and compact 96 × 48 mm DIN panel format. It functions as a standalone display node within a measurement loop, converting raw sensor signals into calibrated engineering-unit readouts without requiring an upstream PLC or HMI for basic indication tasks.
In process industries where operator visibility of live measurement data is a safety and compliance requirement, the DPM-GS-2GW-S occupies a well-defined role: it sits between the field transmitter and the control room, providing local indication with independent switching logic. The dual relay outputs (-2GW suffix) allow the unit to drive alarm annunciators, solenoid valves, or interlock circuits directly — eliminating the need for a separate relay module in simple two-setpoint control loops.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Manufacturer | NEGELE Messtechnik GmbH |
| Part Number | DPM-GS-2GW-S |
| Series | DPM-GS (Universal Process Display) |
| Product Category | Panel-Mount Digital Process Indicator |
| Display Format | 4-digit LED, 14 mm character height |
| Input Signal Types | Thermocouple (J, K, T, S, B, E, N, R), RTD (Pt100, Pt1000), 4–20 mA, 0–10 V, 0–5 V, potentiometer |
| Measurement Accuracy | ±0.2% FS ±1 digit (typical) |
| Relay Outputs | 2 × SPDT relay, 5 A / 250 V AC (resistive load) |
| Output Suffix (-2GW) | Dual relay switching output with independent setpoint assignment |
| Supply Voltage | 85–265 V AC / 20–60 V DC (universal) |
| Power Consumption | ≤ 5 VA |
| Panel Cutout | 92 × 45 mm (1/8 DIN) |
| Mounting Depth | ≤ 110 mm behind panel |
| Front Panel Protection | IP65 (IEC 60529) |
| Rear Terminal Protection | IP20 |
| Operating Temperature | -10 °C to +55 °C |
| Storage Temperature | -25 °C to +70 °C |
| Relative Humidity | ≤ 85% RH, non-condensing |
| EMC Compliance | EN 61326-1 (industrial environment) |
| Safety Standard | EN 61010-1, CE marked |
| Country of Origin | Germany |
| Weight (packaged) | 1,380 g |
| Lead Time (in-stock) | Ships within 3–5 business days from Xiamen, China |
| Lead Time (sourced) | 7–15 business days depending on global availability |
| Warranty | 12 months from date of shipment against manufacturing defects |
Hardware Logical Analysis
The DPM-GS-2GW-S is built around a dedicated signal-conditioning front end that handles the impedance transformation and linearization of diverse sensor types before the signal reaches the analog-to-digital conversion stage. For thermocouple inputs, the unit incorporates cold-junction compensation (CJC) circuitry — a precision thermistor or RTD element mounted at the terminal block — which continuously measures ambient temperature at the connection point and applies a real-time offset correction to the measured EMF. This eliminates the systematic error that would otherwise accumulate in environments with fluctuating ambient temperatures, a common condition in industrial control panels.
For RTD inputs (Pt100, Pt1000), the measurement circuit uses a three-wire or four-wire connection topology to cancel lead resistance errors. The excitation current source is kept low (typically ≤ 1 mA) to prevent self-heating of the resistance element, which would introduce a positive offset error in the displayed value — a critical consideration in hygienic temperature measurement applications where NEGELE’s core market expertise lies.
The dual relay output stage (-2GW) uses independent setpoint registers, each with configurable hysteresis bands. This prevents relay chatter at the switching threshold — a failure mode that accelerates contact wear and generates conducted EMI on the supply rail. The hysteresis window is user-programmable via the front-panel keypad, allowing the engineer to match the switching dead-band to the process dynamics without external timing relays.
EMC performance is addressed at the hardware level through differential-mode and common-mode filtering on the signal input lines, transient suppression diodes (TVS) across relay coil drivers, and a switching power supply designed to meet EN 61326-1 Class A conducted and radiated emission limits. The universal supply input (85–265 V AC / 20–60 V DC) uses a galvanically isolated DC-DC converter stage, which provides ≥ 1.5 kV isolation between the supply rail and the measurement circuitry — protecting the sensor loop from ground-loop currents that would corrupt low-level thermocouple signals.
The front panel achieves IP65 sealing through a continuous elastomeric gasket compressed between the bezel and the panel cutout surface. This construction is compatible with periodic washdown procedures using low-pressure water jets, making the unit suitable for food-grade and pharmaceutical panel installations where hygiene protocols require regular cleaning of control surfaces.
System Integration Benefits
- Standalone Operation Without PLC Dependency: The DPM-GS-2GW-S executes its full indication and switching function without any host controller. In simple two-setpoint alarm loops, this eliminates a PLC I/O card, associated wiring, and the software logic block — reducing both hardware cost and software validation scope in regulated environments.
- Universal Input Reduces Spare-Part Inventory: A single DPM-GS-2GW-S unit covers thermocouple, RTD, and standard analog signal types. Maintenance teams can stock one model to cover multiple measurement loop types across a facility, reducing spare-part SKU count and associated inventory carrying cost.
- Independent Dual Setpoint Switching: Two relay outputs with individually configurable setpoints and hysteresis allow the unit to simultaneously drive a warning alarm and a shutdown interlock from a single measured variable — a function that would otherwise require two separate relay modules or a PLC output card.
- Cold-Junction Compensation for Thermocouple Accuracy: Integrated CJC eliminates the need for an external isothermal terminal block assembly, simplifying panel wiring and removing a potential source of measurement error in installations where the panel temperature varies with ambient conditions.
- IP65 Front Seal for Washdown Environments: Compliance with IP65 allows installation in food processing, beverage, and pharmaceutical panels where periodic cleaning with water or mild detergent solutions is required. This extends the applicable installation environments beyond standard dry industrial panels.
- Universal Supply Voltage Simplifies Global Deployment: The 85–265 V AC / 20–60 V DC supply range covers all standard industrial supply voltages worldwide. A single hardware configuration can be deployed across facilities in different countries without supply voltage variants, simplifying global spare-part standardization.
- Galvanic Isolation Protects Sensor Loop Integrity: The ≥ 1.5 kV isolation between supply and measurement input prevents ground-loop currents from corrupting sensor signals — a common source of measurement drift in large industrial installations with multiple earthing points across the plant.
- Front-Panel Parameter Configuration Without External Tools: All setpoints, input type selection, display scaling, and hysteresis parameters are accessible via the front-panel keypad. No proprietary software, programming cable, or laptop is required for commissioning or setpoint adjustment — reducing the skill requirement for field maintenance personnel.
Quality Assurance & Global Logistics
Every NEGELE DPM-GS-2GW-S unit supplied through siemensplc.com is sourced as genuine OEM product, traceable to authorized NEGELE distribution channels. Prior to dispatch, each unit undergoes a structured pre-shipment inspection protocol: physical integrity check of housing, terminal block, and display window; label and part number verification against the purchase documentation; and functional power-on verification where test equipment is available. Units are retained in original manufacturer packaging with ESD-protective inner wrap to preserve the integrity of the measurement electronics during transit.
Our procurement operation is based in Xiamen, China — a designated national-level port city with direct access to Xiamen Gaoqi International Airport and the Port of Xiamen, one of China’s top-five container ports by throughput volume. This geographic position enables reliable access to international express carriers (DHL, FedEx, UPS, TNT) for time-critical shipments, as well as consolidated sea freight for volume orders. Customs documentation is prepared in compliance with Xiamen Customs regulations, with accurate HS code classification and commercial invoice preparation to minimize clearance delays at destination ports. Multi-currency payment is supported including USD, EUR, HKD, and CNY via T/T bank transfer, PayPal, and platform checkout.
A 12-month warranty applies from the date of shipment. Warranty claims are handled directly by our technical team with a defined RMA process: fault description submission by email, return authorization within 2 business days, and replacement dispatch or repair within the agreed service window. Certificate of conformity and product datasheet are available upon request for procurement compliance documentation.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.