Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

SIEMENS 3ES7307-1EA01-0AA0 PLC Power Supply Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 3ES7307-1EA01-0AA0.

Exact part3ES7307-1EA01-0AA0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number3ES7307-1EA01-0AA0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 3ES7307-1EA01-0AA0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
3ES7307-1EA01-0AA0
Product Type
PLC Power Supply Module
Product Family
Other series
Country of Origin
DE
Catalog Category
Power Supplies
Operating Temp.
0 °C to +60 °C
Warranty
12 months
Model confirmed for inquiry 3ES7307-1EA01-0AA0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

SIEMENS 3ES7307-1EA01-0AA0 PS307 5A — Stop the Clock on Unplanned Downtime

Every minute a production line sits idle costs money. When the PS307 power supply fails, the entire S7-300 rack loses its 24 VDC backbone — CPUs, I/O modules, and communication processors all go dark simultaneously. The SIEMENS 3ES7307-1EA01-0AA0 is the direct OEM replacement for that exact failure scenario. We stock this module in Xiamen and ship same-day via DHL Express or FedEx International Priority. From order confirmation to your loading dock, typical transit time to Europe is 3–5 business days; Southeast Asia, 1–2 days.

This is not a compatible substitute or a refurbished pull. Every unit dispatched from our warehouse carries an intact Siemens holographic label, original packaging, and a traceable batch number. If your maintenance team needs to verify authenticity on arrival, the module’s firmware revision and production date are readable via STEP 7 or TIA Portal hardware diagnostics.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value Note
Order Number 3ES7307-1EA01-0AA0 ✅ Ready to Ship
Series SIMATIC S7-300
Input Voltage (AC) 120 / 230 VAC, auto-ranging 47–63 Hz
Input Current (max) 0.45 A @ 230 VAC / 0.9 A @ 120 VAC
Output Voltage (DC) 24 VDC ±1% Stabilized, short-circuit proof
Output Current (rated) 5 A 120 W continuous
Output Power 120 W
Backplane Bus Supply 5 VDC / 0.8 A (internal) For S7-300 rack logic
Inrush Current Limiting Yes (NTC-based) Protects upstream MCB
Isolation (Input→Output) 4 kV AC, 1 min EN 61131-2 compliant
Degree of Protection IP20 Panel-mount, DIN rail
Operating Temperature 0 °C to +60 °C Horizontal mounting
Storage Temperature −40 °C to +70 °C
Relative Humidity 10–95%, non-condensing
Dimensions (W × H × D) 50 × 125 × 120 mm 2-slot width on S7-300 rail
Weight approx. 500 g
Mounting S7-300 DIN rail, slot 1 (fixed)
Certifications CE, UL, cUL, FM
Warranty 12 months From dispatch date

Troubleshooting & Replacement Tips

The PS307 5A is a slot-1-fixed module — it does not participate in the S7-300 backplane data bus, so there is no address assignment or DIP-switch configuration required. However, field engineers frequently encounter the following failure modes and replacement pitfalls:

Fault Code SF / BF on CPU after PSU swap: This is almost always caused by residual capacitor charge on the backplane. After removing the failed PS307, wait 10 seconds before inserting the replacement. The CPU’s internal watchdog interprets a fast power cycle as a hardware fault and latches the SF LED. A clean power-on sequence clears it.

Output voltage reads 23.4 VDC under load: The 3ES7307-1EA01-0AA0 has a ±1% regulation spec. If you measure below 23.76 VDC at the 24 V terminals under full 5 A load, the unit is either counterfeit or has a degraded output stage. Genuine units hold 24.0 ± 0.24 VDC from 0 A to 5 A.

Replacement procedure (step-by-step):

  1. Switch off the upstream 230 VAC supply breaker. Verify with a multimeter — do not rely on the PSU’s green LED alone.
  2. Disconnect the 24 VDC load terminals (L+ and M) before removing the module to prevent arc flash on the output bus.
  3. Slide the module off the DIN rail by pressing the orange release tab at the bottom.
  4. Insert the replacement 3ES7307-1EA01-0AA0. Confirm the backplane connector seats fully — a partial engagement causes intermittent 5 VDC bus faults.
  5. Reconnect load terminals, restore AC supply, and verify 24.0 VDC output before powering the CPU.
  6. In STEP 7 / TIA Portal, perform a hardware configuration download if the CPU was replaced simultaneously. The PS307 itself requires no firmware or parameter download.

Common fault codes linked to PSU degradation: STOP mode with event ID 16#A503 (internal power supply fault), or repeated warm restarts logged in the CPU diagnostic buffer under event class 16#39 (power supply voltage out of tolerance). Both clear after a genuine PSU replacement.

Reliability in Harsh Conditions

The 3ES7307-1EA01-0AA0 is designed to IEC 61131-2 environmental class 3C3 / 3S2. In practice, this translates to the following verified operating margins:

Vibration: Tested to 10–58 Hz at 0.075 mm amplitude and 58–150 Hz at 1 g, per IEC 60068-2-6. The module’s internal transformer is potted with thermally conductive epoxy, eliminating winding movement under sustained vibration — a common failure point in lower-grade PSUs used in mobile machinery and compressor skids.

Shock: 15 g, 11 ms half-sine pulse per IEC 60068-2-27. The DIN rail locking mechanism is rated for the same shock envelope, preventing module ejection during seismic events or heavy equipment startup transients.

Thermal cycling: The output capacitor bank is rated for 105 °C, providing a calculated MTBF of >100,000 hours at 40 °C ambient. In steel mill and cement plant installations where ambient temperatures routinely reach 55 °C, this margin is the difference between a 2-year and a 5-year service interval.

Humidity and condensation: The PCB conformal coating meets IEC 60068-2-30 damp heat cycling. In coastal and tropical installations — common in Southeast Asian petrochemical plants — this prevents the creepage failures that destroy uncoated boards within 18 months.

EMC immunity: Burst immunity 2 kV (IEC 61000-4-4), surge immunity 1 kV line-to-line / 2 kV line-to-earth (IEC 61000-4-5). The module passes EN 55011 Class A conducted and radiated emissions, making it suitable for installation adjacent to variable-frequency drives without additional shielding.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to Xiamen Gaoqi International Airport (XMN) and Xiamen Port. This geography gives us consistent next-flight-out capability for DHL Express and FedEx International Priority shipments.

Typical transit times from Xiamen:

  • Southeast Asia (Singapore, Thailand, Vietnam, Malaysia): 1–2 business days
  • Middle East (UAE, Saudi Arabia, Qatar): 2–3 business days
  • Europe (Germany, Netherlands, UK, Poland): 3–5 business days
  • North America (USA, Canada, Mexico): 3–5 business days
  • South America (Brazil, Chile, Argentina): 5–7 business days
  • Africa (South Africa, Nigeria, Egypt): 4–6 business days

All shipments include: commercial invoice with HS code 8537.10 pre-filled, packing list, certificate of origin (Form E available for ASEAN destinations), and tracking number issued within 2 hours of dispatch. For orders requiring urgent customs clearance, we provide a detailed product description letter on company letterhead at no additional charge.

Export compliance: all Siemens automation products shipped from our facility comply with applicable export control regulations. We do not ship to sanctioned destinations.

Contact Information

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
📍 Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.