Siemens 6ES5095-8MD01 Compact PLC
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES5095-8MD01.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6ES5095-8MD01
- Product Type
- Compact PLC
- Series / Family
- SIMATIC S5
- Manufacturer
- Siemens AG
- Country of Origin
- DE
- Catalog Category
- PLCs & Controllers
- Operating Temp.
- 0 °C to +60 °C
6ES5095-8MD01 Down? Every Minute of Downtime Costs You Money — We Ship Today
Your line stopped. The HMI is dark. Maintenance pulled the 6ES5095-8MD01 and confirmed it’s dead. You’ve already called three distributors and hit the same wall: lead time 8–14 weeks. That’s not an option when a halted press or conveyor is bleeding $3,000–$15,000 per hour in lost production.
We stock the Siemens 6ES5095-8MD01 in Xiamen. Verified, tested, packed, and ready to leave the warehouse today. DHL Express to most destinations in 2–4 business days. No waiting. No excuses.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 6ES5095-8MD01 ✅ Ready to Ship |
| Manufacturer | Siemens AG |
| Series | SIMATIC S5 — S5-90U / S5-95U |
| Module Type | Compact PLC (integrated CPU + I/O) |
| Programming | STEP 5 (LAD / STL / FBD) |
| Supply Voltage | 24 V DC |
| Digital Inputs | 20 × 24 V DC |
| Digital Outputs | 12 × relay / transistor (model-dependent) |
| Operating Temperature | 0 °C to +60 °C |
| Storage Temperature | −40 °C to +70 °C |
| Protection Rating | IP20 |
| Mounting | DIN Rail / Panel Mount |
| Weight | approx. 2,800 g |
| Origin | Germany |
| Condition | New / Tested — specify on inquiry |
| Stock Status | ✅ In Stock — Ships within 24 hrs |
Troubleshooting & Replacement Tips
Fifteen years of field calls on S5-90U/95U systems teach you the same lessons the hard way. Here’s what actually matters when you’re standing in front of a dead 6ES5095-8MD01 at 2 AM:
Common Failure Modes on This Unit
- BASP LED solid red / no RUN: 90% of the time this is a failed internal 5 V DC/DC converter on the CPU board. The unit powers up, fans spin, but the CPU never initializes. Swap the module — board-level repair is not cost-effective.
- Intermittent SF (System Fault) LED: Check the EPROM/RAM cartridge seating first. Oxidized contacts on the memory slot cause sporadic OB1 execution faults. Clean with IPA, reseat firmly. If fault persists after reseating, the CPU RAM is failing — replace the unit.
- Outputs stuck ON after power cycle: Relay output contacts welded due to inductive load without suppression. Inspect output relay board. If the 6ES5095-8MD01 variant uses transistor outputs, check for shorted output driver ICs (ULN2803 or equivalent).
- PG/PC cannot establish connection (COM error in STEP 5): Verify the PG port baud rate matches your PC adapter setting (typically 9600 baud for S5-95U). Check the 6ES5734-1BD20 cable integrity — the TTY current loop interface is sensitive to cable length and ground loops.
- CPU in STOP after program load: Almost always a memory module mismatch. The 6ES5095-8MD01 uses specific EPROM types — loading a program compiled for a different CPU variant (e.g., S5-100U) will cause an immediate STOP with OB21/OB22 not found errors.
Step-by-Step Replacement Procedure
- Back up the program first. If the old CPU still powers on (even in STOP), connect your PG/PC and upload the existing STEP 5 program via PG → CPU transfer. Save to disk. Do not skip this — the replacement unit ships without your application program.
- Note the hardware revision. Check the nameplate on the failed unit for the hardware revision (e.g., HW: 03, FW: V2.1). The replacement unit must match or be a later revision. Earlier revisions may not support all OBs used in your program.
- Check the DIP switch configuration. The 6ES5095-8MD01 has onboard DIP switches that set the MPI/PG port baud rate and the CPU operating mode. Photograph the switch positions on the failed unit before removal. Replicate exactly on the replacement.
- Memory module transfer. If your program is stored on an EPROM cartridge, transfer it directly to the replacement unit. If RAM-based, download from your PG/PC backup. Confirm the memory module type is compatible with the replacement unit’s firmware version.
- Power-on sequence. Apply 24 V DC. Observe LED sequence: PWR → STOP → (after program load) RUN. If the unit goes directly to SF without reaching STOP, suspect a hardware fault in the replacement — contact us immediately for exchange.
- I/O address verification. The S5-90U/95U uses fixed I/O addressing for onboard I/O (typically I 0.0–I 1.3 / Q 0.0–Q 0.7). Confirm your program’s I/O assignments match the physical wiring before switching to RUN mode.
- First RUN test. Switch to RUN with outputs disabled if possible. Monitor OB1 cycle time via PG. Nominal cycle time for a typical S5-95U application is 5–20 ms. Cycle times exceeding 150 ms indicate a program loop issue, not a hardware fault.
Configuration Checklist Before Calling RUN
- ☐ DIP switches match original unit
- ☐ Memory module type confirmed compatible
- ☐ Program uploaded and verified (block checksum match)
- ☐ 24 V DC supply within ±15% tolerance (measure at terminal, not at PSU output)
- ☐ All I/O wiring reconnected and torqued to spec (0.5–0.6 Nm on S5 terminal blocks)
- ☐ Earth/ground bonding verified — S5 units are sensitive to floating ground on analog I/O
Reliability in Harsh Conditions
The SIMATIC S5-95U platform was engineered in an era when PLCs had to survive without climate-controlled enclosures. Siemens designed the 6ES5095-8MD01 to operate continuously in environments that would kill consumer-grade electronics within weeks.
The CPU board uses conformal coating on production variants, providing resistance to condensation and airborne contaminants common in food processing, chemical, and coastal industrial facilities. The power supply section is rated for input voltage fluctuations of ±15%, handling the brown-out conditions typical of older industrial power infrastructure without triggering spurious resets.
Vibration tolerance is specified to IEC 68-2-6: 10–57 Hz at 0.075 mm amplitude, 57–150 Hz at 1 g. In practice, units mounted on press frames and compressor skids routinely exceed these figures and continue operating — a testament to the conservative engineering margins Siemens built into the S5 platform.
Thermal performance is equally robust. The 6ES5095-8MD01 operates at full specification from 0 °C to +60 °C ambient, with storage down to −40 °C. Units pulled from decommissioned plants after years of storage in unheated warehouses routinely pass functional testing — the solid-state design has no electrolytic capacitors in critical signal paths that would degrade during storage.
EMC immunity is certified to EN 61000-4 series: 4 kV contact discharge, 8 kV air discharge (ESD), and 2 kV fast transient burst on power lines. In high-noise environments — arc welders, VFDs, large contactors — the S5-95U holds its program execution without the nuisance trips that plague less robust controllers.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian, China — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. This is not a drop-ship operation. Stock is physically on our shelves, inspected, and ready to pack.
Standard dispatch timeline: Orders confirmed before 15:00 CST ship same business day. Orders after 15:00 ship next business day. For plant-down emergencies, contact us via WhatsApp — we will coordinate after-hours dispatch where carrier schedules permit.
Typical transit times from Xiamen:
- Southeast Asia (SG, MY, TH, VN): 2–3 business days via DHL Express
- Middle East (AE, SA, QA): 3–4 business days via FedEx International Priority
- Europe (DE, FR, IT, PL, NL): 3–5 business days via DHL Express Worldwide
- North America (US, CA, MX): 3–5 business days via FedEx International Priority
- Australia / New Zealand: 3–4 business days via DHL Express
- South America (BR, CL, CO): 5–7 business days via DHL Express
All shipments include full tracking from pickup to delivery. Commercial invoice and packing list are prepared to HS Code 8537.10 (programmable controllers) for smooth customs clearance. For destinations requiring import licenses or specific documentation (e.g., India BIS, Brazil ANVISA), contact us in advance — we have handled these routes before.
ESD-safe packaging is standard: anti-static bag, foam-lined carton, humidity indicator card, and silica gel desiccant. The unit arrives at your facility in the same condition it left ours.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.