Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6ES7134-4GB50-0AB0 Analog Input Module – ET 200S

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES7134-4GB50-0AB0.

Exact part6ES7134-4GB50-0AB0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6ES7134-4GB50-0AB0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6ES7134-4GB50-0AB0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6ES7134-4GB50-0AB0
Product Type
Analog Input Module
Series / Family
SIMATIC
Country of Origin
DE
Catalog Category
I/O Modules
Operating Temp.
0 °C to +60 °C (horizontal mounting); 0 °C to +40 °C (vertical)
Warranty
12 months against manufacturing defects
Model confirmed for inquiry 6ES7134-4GB50-0AB0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6ES7134-4GB50-0AB0 — 2-Channel Analog Input Electronic Module for SIMATIC ET 200S Distributed I/O

The 6ES7134-4GB50-0AB0 is a 2-channel analog input electronic module engineered for the Siemens SIMATIC ET 200S distributed I/O platform. Within a PROFIBUS-DP or PROFINET control architecture, this module occupies a precisely defined slot on the ET 200S station rail and delivers digitized process values — voltage or current — directly onto the backplane bus for consumption by the upstream interface module and, ultimately, the S7 CPU. Its role is not peripheral: in closed-loop process control, the fidelity and latency of analog acquisition at this node directly determines the quality of the PID output and the stability of the control loop.

Deployed across automotive body-in-white lines, chemical reactor control panels, pharmaceutical batch systems, and municipal water treatment SCADA networks, the 6ES7134-4GB50-0AB0 has accumulated a substantial field record in environments where signal integrity and deterministic scan behavior are non-negotiable requirements.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Order Number 6ES7134-4GB50-0AB0
Product Family SIMATIC ET 200S
Module Function Analog Input Electronic Module
Number of Analog Inputs 2 channels (AI)
Measurable Signal — Voltage ±10 V, 0–10 V, 1–5 V, ±5 V, ±2.5 V
Measurable Signal — Current 0–20 mA, 4–20 mA, ±20 mA
Resolution 13 bits + sign (14-bit effective word)
Conversion Time per Channel ≥ 6 ms (50 Hz interference suppression mode)
Permissible Input Voltage (continuous) ≤ ±15 V (voltage mode); ≤ 30 mA (current mode)
Input Resistance — Voltage Mode ≥ 100 kΩ
Input Resistance — Current Mode ≤ 50 Ω (shunt)
Supply Voltage 24 V DC via ET 200S backplane bus
Current Consumption from Bus Typ. 50 mA
Galvanic Isolation Channel group vs. backplane bus: isolated; between channels: not isolated
Interference Suppression 50 Hz / 60 Hz selectable
Dimensions (W × H × D) 15 mm × 81 mm × 52 mm
Weight Approx. 46 g
Operating Temperature 0 °C to +60 °C (horizontal mounting); 0 °C to +40 °C (vertical)
Storage Temperature −40 °C to +70 °C
Relative Humidity 10–95%, non-condensing (IEC 60068-2-30)
Degree of Protection IP20 (IEC 60529)
Shock Resistance 15 g / 11 ms (IEC 60068-2-27)
Vibration Resistance 1 g, 10–58 Hz; 0.075 mm, 58–150 Hz (IEC 60068-2-6)
Compatible Terminal Modules 6ES7193-4CA30-0AA0 (2-wire), 6ES7193-4CA40-0AA0 (4-wire)
Compatible Interface Modules IM 151-1 Standard, IM 151-1 FO, IM 151-3 PN
Certifications CE, UL, cULus, ATEX Zone 2 (II 3 G Ex nA IIC T4)
Warranty 12 months against manufacturing defects

Hardware Logical Analysis

The 6ES7134-4GB50-0AB0 implements a sigma-delta (ΣΔ) analog-to-digital conversion architecture. Unlike successive-approximation (SAR) converters, the sigma-delta topology oversamples the input signal at a high clock rate and applies a digital decimation filter to produce the final 13-bit + sign output word. This approach yields two structural advantages in industrial environments: first, the decimation filter inherently attenuates high-frequency noise and aliasing components without requiring external anti-aliasing circuitry; second, the selectable 50 Hz / 60 Hz notch filter is implemented digitally within the same decimation chain, providing ≥ 60 dB rejection of mains-frequency interference — a critical requirement in panel environments where power cables and signal cables share conduit.

Galvanic isolation architecture: The module provides optical isolation between the analog channel group and the ET 200S backplane bus. The isolation barrier is implemented via a DC/DC converter for power and an optocoupler array for the digital data path. This topology prevents ground loops from propagating from field-side sensors — which may reference a local earth potential differing by several volts from the control cabinet ground — into the backplane bus and corrupting data on adjacent modules. The isolation withstand voltage is rated at 500 V AC (test voltage), consistent with IEC 61131-2 requirements for distributed I/O in industrial environments.

EMC design: The module’s PCB layout follows Siemens’ internal EMC design rules for SIMATIC hardware, including ground-plane partitioning between the analog front-end and the digital processing section, controlled-impedance traces on the sigma-delta clock lines, and ferrite bead filtering on the bus power supply pins. The result is a module that meets EN 61000-6-2 (industrial immunity) and EN 61000-6-4 (industrial emissions) without requiring additional external filtering in standard cabinet installations.

Backplane bus interface: The module communicates with the ET 200S interface module via the proprietary SIMATIC ET 200S local bus, a synchronous serial protocol operating at a fixed clock rate determined by the IM. The IM polls each electronic module in a fixed slot sequence during each DP cycle, ensuring that analog values are refreshed at a rate consistent with the PROFIBUS-DP cycle time configured in STEP 7 or TIA Portal. The module’s internal conversion time (≥ 6 ms at 50 Hz suppression) must be accounted for in the DP cycle time budget; if the DP cycle is shorter than the conversion time, the module will return the previous conversion result — a behavior that must be understood during commissioning of fast control loops.

ATEX Zone 2 compliance: The module carries Ex nA IIC T4 certification, classifying it as non-sparking equipment suitable for Zone 2 (occasionally explosive atmosphere) installations. This certification requires that the module be installed in an enclosure providing at least IP54 protection when deployed in hazardous areas, and that the supply voltage remain within the specified 24 V DC ±20% tolerance under all fault conditions.

System Integration Benefits

  • Zero-configuration hardware recognition: TIA Portal and STEP 7 automatically identify the 6ES7134-4GB50-0AB0 by its GSD/GSDML device description. The engineer selects the module from the hardware catalog, assigns the I/O address, and the software generates the correct parameter assignment telegram — no manual register mapping required.
  • Parameterizable measurement range per channel: Each of the two channels can be independently configured for a different signal type (e.g., channel 0 for 4–20 mA, channel 1 for 0–10 V) via the hardware configuration in TIA Portal. This eliminates the need for separate modules when a station mixes sensor types.
  • Integrated diagnostic messaging: The module generates diagnostic interrupts for wire-break detection (in 4-wire current mode), overflow, and underflow conditions. These interrupts are forwarded via the IM to the CPU’s OB82 diagnostic interrupt OB, enabling the application program to respond to sensor faults within one CPU scan cycle without polling.
  • Deterministic scan behavior: Because the ET 200S local bus operates on a fixed polling schedule synchronized to the PROFIBUS-DP cycle, the analog input values presented to the CPU are time-consistent within a single DP cycle. This is essential for multi-variable control algorithms where the relative timing of different process measurements affects control quality.
  • Compact 15 mm slot pitch: The module’s 15 mm width allows high-density I/O configurations on the ET 200S rail. A single ET 200S station can accommodate up to 63 electronic modules (subject to power budget), enabling large analog I/O counts within a single PROFIBUS node address — reducing network complexity and DP cycle time.
  • Seamless migration path: The module is compatible with all ET 200S interface modules from IM 151-1 Standard through IM 151-3 PN, allowing existing PROFIBUS-DP stations to be migrated to PROFINET by replacing only the IM, with no changes to the electronic module population or terminal wiring.
  • TIA Portal V13–V19 support: The module’s device description is included in all current TIA Portal versions, ensuring that projects created with older software versions can be opened and modified in current engineering environments without hardware reconfiguration.
  • Consistent representation in the process image: Analog values are stored in the CPU’s process image input (PII) as 16-bit signed integers in Siemens’ standard analog representation format (−27648 to +27648 for the nominal range), compatible with the standard analog scaling function blocks (FC105/FC106 in STEP 7, NORM_X/SCALE_X in TIA Portal) without custom scaling code.

Quality Assurance & Global Logistics

Every unit of the 6ES7134-4GB50-0AB0 supplied through siemensplc.com is sourced as genuine Siemens OEM hardware. Each module carries a factory-assigned serial number traceable through Siemens’ product authentication system. Before dispatch, units undergo a multi-stage inspection protocol: visual examination of the housing, connector pins, and label authenticity; functional power-on verification; and packaging integrity check. Modules are shipped in original Siemens anti-static packaging or equivalent ESD-safe packaging with desiccant, meeting IEC 61340-5-1 electrostatic discharge protection requirements for sensitive electronic assemblies.

Our logistics operations are based in Xiamen, China — a major international port city with direct air freight connections to Frankfurt, Amsterdam, Los Angeles, Dubai, and Singapore. Standard export documentation includes commercial invoice, packing list, and certificate of origin. For regulated industries, a certificate of conformity and incoming inspection report are available on request. Typical dispatch lead time for in-stock items is 1–3 business days from order confirmation. International express delivery (DHL, FedEx, UPS) to most destinations in Europe, North America, Southeast Asia, and the Middle East is achieved within 3–7 business days. For bulk orders or long-term supply agreements, sea freight consolidation and bonded warehouse arrangements can be coordinated on request.

All supplied units carry a 12-month warranty against manufacturing defects, covering failure under normal operating conditions within the module’s specified environmental and electrical ratings. Warranty claims are processed with a target response time of 48 hours from receipt of the defective unit.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.