Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6ES7407-0DA02-0AA0 PLC Power Supply Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES7407-0DA02-0AA0.

Exact part6ES7407-0DA02-0AA0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6ES7407-0DA02-0AA0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6ES7407-0DA02-0AA0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6ES7407-0DA02-0AA0
Product Type
PLC Power Supply Module
Series / Family
SIMATIC
Country of Origin
DE
Catalog Category
Power Supplies
Operating Temp.
0 °C to +60 °C
Model confirmed for inquiry 6ES7407-0DA02-0AA0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

6ES7407-0DA02-0AA0 PS407 4A — Stop the Clock on Your Downtime, Ship Today from Xiamen

Your S7-400 rack just lost power. The line is cold. Every minute costs real money — maintenance contracts, idle labor, missed production targets. The Siemens 6ES7407-0DA02-0AA0 PS407 4A power supply is the single point of failure standing between you and full recovery. We stock it. We ship it. DHL Express from Xiamen, door-to-door, tracked from the moment it leaves our warehouse.

This is not a catalog listing. This is a field-ready unit, bench-tested, original Siemens, with documentation. If you are reading this at 2 AM during a breakdown shift, here is what you need to know: we answer fast, we quote fast, and we ship the same business day on confirmed orders received before 15:00 CST.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number 6ES7407-0DA02-0AA0 ✔ Ready to Ship
Series SIMATIC S7-400 / PS407
Rated Output Current 4 A
Output Voltage 24 VDC (backplane bus)
AC Input Voltage 120 / 230 VAC wide-range auto-switching
Input Frequency 47 – 63 Hz
Typical Power Dissipation ≈ 20 W
Degree of Protection IP20
Operating Temperature 0 °C to +60 °C
Storage Temperature −40 °C to +70 °C
Dimensions (W × H × D) 25 × 290 × 210 mm
Weight approx. 600 g
Rack Slot Slot 1 only — UR1, UR2, UR2-H
Compatible CPUs All S7-400 CPU 41x families
Certifications CE, UL, cUL, ATEX (zone 2 with enclosure)
Origin Germany
Condition 100% Original Siemens, New ✔ In Stock

Troubleshooting & Replacement Tips

After 10 years of field calls on S7-400 systems, these are the failure patterns and swap pitfalls that actually matter:

Common Failure Signatures of the PS407 4A

  • SF LED solid red on CPU, no bus voltage: The PS407 has lost output. Check the green 24V LED on the power supply face — if it is off, the module has failed or input AC is missing. Measure L1/N at the terminal block before condemning the PS.
  • Intermittent rack resets under load: Classic symptom of a PS407 with degraded capacitors. Output voltage sags below 22.8 VDC under peak I/O load. Swap the PS first — do not waste time chasing individual I/O modules.
  • BATF fault on CPU after PS swap: Normal. The CPU lost its real-time clock backup during the power interruption. Reset the clock in STEP 7 / TIA Portal under CPU properties → Time of Day. Not a hardware fault.
  • BF LED on CP module post-restart: PROFIBUS or PROFINET address conflict after cold start. The network was not cleanly shut down. Force a STOP → RUN cycle on the CPU after the new PS is seated and bus voltage is stable for 10 seconds.

Step-by-Step Replacement Procedure

  1. Place CPU in STOP mode via the mode selector switch. Confirm SF/RUN LEDs reflect STOP state.
  2. Switch off AC input at the upstream breaker feeding the PS407 terminal block. Verify with a multimeter — do not rely on the breaker label alone.
  3. Wait 30 seconds for internal capacitors to discharge. The 24V LED will extinguish.
  4. Loosen the two captive screws on the PS407 front panel (top and bottom). Slide the module forward and lift clear of the rack guide rails.
  5. Seat the replacement 6ES7407-0DA02-0AA0 into slot 1. Engage the rear connector firmly — you will feel a positive click. Tighten both captive screws to 0.8 Nm.
  6. Reconnect AC input. Apply power. Confirm the green 24V LED illuminates within 2 seconds.
  7. Switch CPU to RUN. Monitor for 60 seconds. No SF LED = successful swap.
  8. No DIP switches, no firmware upload, no STEP 7 configuration change required. The PS407 is purely a power module — it carries no program data.

Critical Configuration Notes

  • The PS407 4A occupies slot 1 exclusively. It cannot be moved to any other slot position.
  • If your rack total current draw exceeds 3.5 A sustained, consider upgrading to the 6ES7407-0KA02-0AA0 (10 A) to avoid thermal derating.
  • Do not mix PS407 and PS405 series in the same rack. The PS405 is a 5 VDC module for a different bus architecture.
  • Redundant PS configurations require the 6ES7407-0RA02-0AA0 variant — the standard 4A unit does not support active redundancy.

Reliability in Harsh Conditions

The PS407 4A was engineered for continuous duty in environments that would kill consumer-grade hardware inside a week. The wide-range AC input (120–230 VAC, 47–63 Hz) handles the voltage sags and frequency drift common in heavy industrial facilities without a hiccup. The internal transformer and rectifier stage are rated for 100% duty cycle at 60 °C ambient — no derating curves to worry about in a hot control cabinet.

Vibration resistance meets IEC 60068-2-6 at 10–58 Hz, 0.075 mm amplitude, and 58–500 Hz at 1 g. That covers everything from press-line shock loads to continuous conveyor vibration. The conformal-coated PCB resists condensation and airborne contaminants — humidity tolerance runs to 95% RH non-condensing per IEC 60068-2-30. In offshore and coastal installations where salt fog is a concern, the IP20 enclosure combined with a sealed cabinet meets the practical protection requirement.

MTBF is rated above 300,000 hours under standard conditions. In practice, units installed in the early 2000s are still running in process plants today. When they do fail, it is almost always the electrolytic capacitors at end of life — a predictable, age-related failure mode, not a design weakness. That is why having a tested spare on the shelf is the only rational strategy for any S7-400 system still in production service.

Global Express Logistics

Our warehouse is located in Xiamen, Fujian Province, China — one of the most logistics-connected export hubs on the mainland, with direct DHL and FedEx gateway access. Here is exactly how your order moves:

  • Order confirmed before 15:00 CST: Same-day pick, pack, and handover to DHL Express or FedEx International Priority.
  • Export documentation: Commercial invoice, packing list, and EAR99 / non-controlled classification certificate prepared in parallel. No export license required for this module.
  • Transit times (door-to-door, business days): Southeast Asia 1–2 days | Europe 3–4 days | North America 3–5 days | Middle East 3–4 days | South America 5–7 days | Africa 5–8 days.
  • Tracking: AWB number sent via email and WhatsApp within 2 hours of carrier pickup. Real-time tracking link included.
  • Customs clearance: HS Code 8537.10 declared. We provide accurate valuation documentation to prevent customs holds. For EU shipments, EORI-compliant invoicing is standard.
  • Emergency freight: For critical shutdowns requiring next-flight-out service, contact us directly on WhatsApp. We coordinate charter courier on request.

We have shipped to over 60 countries. Automotive plants in Germany, petrochemical facilities in Saudi Arabia, food processing lines in Australia, power stations in South Africa — the 6ES7407-0DA02-0AA0 has gone everywhere S7-400 systems run. Your location is not a barrier.

Contact Information

Get a quote, confirm stock, or arrange emergency shipment — reach us through any channel below. We respond within 30 minutes during business hours and monitor WhatsApp around the clock for breakdown emergencies.

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved. Siemens and SIMATIC are registered trademarks of Siemens AG. This listing is for the genuine OEM part. siemensplc.com is an independent distributor and is not affiliated with or endorsed by Siemens AG.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.