Siemens 6ES7650-8DK80-1AA0 Analog Input Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for 6ES7650-8DK80-1AA0.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- 6ES7650-8DK80-1AA0
- Product Type
- Analog Input Module
- Series / Family
- SIMATIC
- Manufacturer
- Siemens
- Country of Origin
- DE
- Catalog Category
- I/O Modules
- Operating Temp.
- 0 °C to +60 °C
6ES7650-8DK80-1AA0 — Stop the Bleeding: Every Hour of Downtime Costs You Money
Your ET 200 rack just threw a fault. The line is cold. Maintenance is standing by. You’ve already pulled the module and confirmed it’s the 6ES7650-8DK80-1AA0 — a 4-channel, 16-bit analog input card that sits at the heart of your process signal chain. You don’t need a lecture on specifications. You need the part, tested, boxed, and moving toward your dock today.
We stock the Siemens 6ES7650-8DK80-1AA0 in Xiamen. Units are function-tested before dispatch. DHL and FedEx express lanes are open. If you place your order before cut-off, this module can be wheels-up within hours — not days.
⚡ URGENT REQUIREMENT?
Email: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Value | Status |
|---|---|---|
| Part Number | 6ES7650-8DK80-1AA0 | ✅ Ready to Ship |
| Manufacturer | Siemens | — |
| Product Family | SIMATIC ET 200 | — |
| Module Function | Analog Input (AI) | — |
| Number of Channels | 4 (configurable 0/4) | — |
| Signal Range | 0–20 mA / 4–20 mA | — |
| Resolution | 16-bit | — |
| Supply Voltage | 24 V DC | — |
| Channel Isolation | Electrically isolated | — |
| Mounting | DIN rail / ET 200 backplane | — |
| Operating Temperature | 0 °C to +60 °C | — |
| Protection Rating | IP20 | — |
| Bus Interface | PROFIBUS DP | — |
| Certifications | CE, UL, cULus | — |
| Weight | Approx. 500 g | — |
| Origin | Germany | — |
| Stock Location | Xiamen, China | ✅ In Stock |
Troubleshooting & Replacement Tips
Swapping a 6ES7650-8DK80-1AA0 is not just a pull-and-plug operation. Here’s what bites engineers in the field:
1. Address Assignment — Don’t Skip This
The ET 200 system uses slot-based addressing. When you seat the new module, STEP 7 or TIA Portal must recognize it at the correct slot address. If your project was configured with a fixed slot assignment, verify the hardware configuration matches before going online. A mismatch here will throw a Module Not Found or Configuration Error diagnostic — the line stays down and you waste another hour.
2. DIP Switch / Parameterization
This module does not use physical DIP switches for channel configuration — parameterization is done entirely via the software (STEP 7 HW Config or TIA Portal device properties). Before downloading, confirm your channel measurement type (current vs. voltage), wire mode (2-wire, 3-wire, 4-wire transmitter), and diagnostic interrupt settings match your process requirements. A wrong wire-mode setting on a 4–20 mA loop will give you a flat zero or a wire-break fault immediately on startup.
3. Firmware Compatibility
If your ET 200 head station (IM module) is running older firmware, a newer hardware revision of the 6ES7650-8DK80-1AA0 may not be recognized. Check the hardware revision suffix on the module label against your IM firmware version. Siemens publishes compatibility matrices in the product support portal — cross-reference before you install.
4. Common Fault Codes to Know
- SF LED solid red: Module parameterization error — re-download HW config.
- BF LED flashing: Bus fault — check PROFIBUS cable termination and address conflicts.
- Channel diagnostic 0x0A (Wire Break): Open circuit on the current loop — verify field wiring continuity before blaming the module.
- OVF (Overflow) in process image: Input signal exceeds configured range — check transmitter output and scaling.
- Module substitution error in TIA Portal: Hardware revision mismatch — enable “Accept different module” in device properties or update IM firmware.
5. Calibration After Replacement
The 6ES7650-8DK80-1AA0 is factory-calibrated. No field calibration is required after a like-for-like swap. However, if your process uses scaled engineering units in the PLC program, verify the scaling blocks (FC105 in STEP 7 or standard scaling in TIA) are intact and not corrupted in the data block.
Reliability in Harsh Conditions
Industrial environments don’t care about your schedule. Vibration from compressors and conveyors, temperature swings between day and night shifts, humidity in coastal or chemical plant installations — the 6ES7650-8DK80-1AA0 is built to absorb all of it without drifting out of spec.
The module’s electrically isolated channel design means a ground fault on one field instrument won’t cascade into adjacent channels or corrupt your process image. EMC shielding meets IEC 61000 requirements, so it holds its 16-bit resolution even in panels with variable-frequency drives running nearby. The DIN rail mounting with positive locking ensures the module doesn’t work itself loose under continuous vibration — a failure mode that plagues cheaper third-party alternatives.
Operating range of 0 °C to +60 °C covers the vast majority of industrial cabinet environments. For applications pushing the upper boundary — foundries, outdoor enclosures in tropical climates — ensure your panel cooling is adequate before attributing signal drift to the module itself. The hardware is not the weak link; the thermal management of the enclosure usually is.
Units we ship have been stored in climate-controlled conditions and inspected for physical integrity: connector pins, backplane edge connector, and housing latches are all verified before boxing. We do not ship modules with bent pins or cracked housings — those go to the reject pile, not to your plant.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian, China — one of the country’s primary export ports with direct DHL and FedEx gateway access. Here’s how your order moves:
- Order confirmed → same-day or next-morning dispatch for orders placed before 16:00 CST.
- Packaging: Anti-static ESD bag, foam-lined carton, clearly labeled with part number and serial. Export documentation (commercial invoice, packing list, HS code declaration) included in every shipment.
- DHL Express: Europe 2–3 business days, North America 3–4 business days, Southeast Asia 1–2 business days.
- FedEx International Priority: Available on request — same transit benchmarks, useful when DHL capacity is constrained.
- Tracking: AWB number sent to your email within 2 hours of dispatch. Real-time tracking link provided.
- Customs & Duties: We declare accurate commercial values and provide HS code 8537.10 documentation. DAP (Delivered At Place) terms available — you handle import duties at destination. DDP available for select regions — ask when ordering.
- Emergency freight: For genuine production-stop situations, contact us directly on WhatsApp. We can arrange same-day courier pickup and priority airline routing.
We’ve shipped to Germany, the Netherlands, India, Brazil, Australia, and across Southeast Asia. The process is the same every time: fast, documented, and trackable from our warehouse to your receiving dock.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.