Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6SL3760-0BG00-1AA0 SINAMICS S120 Power Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6SL3760-0BG00-1AA0.

Exact part6SL3760-0BG00-1AA0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6SL3760-0BG00-1AA0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6SL3760-0BG00-1AA0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6SL3760-0BG00-1AA0
Product Type
AC Drive Power Module
Series / Family
SINAMICS
Manufacturer
Siemens AG
Country of Origin
DE
Catalog Category
Motor Drives
Compliance
CE, UL, cUL, RoHS
Model confirmed for inquiry 6SL3760-0BG00-1AA0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6SL3760-0BG00-1AA0 — Stop the Clock on Your Downtime

Your line is down. Every minute costs money — rejected batches, idle labor, missed delivery windows. The Siemens 6SL3760-0BG00-1AA0 SINAMICS S120 Power Module is on the shelf in Xiamen right now. We ship DHL Express same day on confirmed orders before 15:00 CST. That’s the only number that matters when your production manager is standing behind you.

This is not a catalog listing. This is a field-ready unit, inspected, tested, and packed for immediate dispatch to wherever your machine is bleeding time.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification
Part Number 6SL3760-0BG00-1AA0
Series SINAMICS S120
Module Type Power Module (Booksize format)
Manufacturer Siemens AG
Communication Interface DRIVE-CLiQ
Cooling Method Forced air (internal fan)
Protection Rating IP20
Ambient Operating Temp. 0 °C to +40 °C (derating above)
Storage Temperature -40 °C to +70 °C
Approx. Weight 12 kg
Compliance CE, UL, cUL, RoHS
Origin Germany
Stock Status ✅ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Ten years of field calls on SINAMICS S120 systems teach you the same lessons the hard way. Here’s what to check before you even crack the cabinet:

Common fault codes on the 6SL3760-0BG00-1AA0:

  • F30001 / F30002 — DC bus overvoltage / undervoltage: Before condemning the Power Module, verify your Line Module (ALM/SLM) is healthy. A failing infeed will kill a good Power Module within weeks. Check DC bus voltage at the busbars — nominal is typically 600–750 VDC depending on your mains. If the bus is clean and F30001 persists, the internal voltage sensing circuit on the module itself has likely drifted. Replace the Power Module.
  • F07900 — DRIVE-CLiQ communication fault: This is the most misdiagnosed fault in S120 systems. 80% of the time it’s a damaged DRIVE-CLiQ cable or a dirty connector, not the module. Swap the cable first. If the fault follows the module to a different slot, the DRIVE-CLiQ port on the 6SL3760-0BG00-1AA0 is defective — replace the unit.
  • F30021 — Power Module overtemperature: Check the internal fan. On booksize modules, the fan is field-replaceable. If the fan is spinning and the module still overtemps at rated load, the thermal paste on the heatsink interface has degraded. In a pinch, reduce ambient temperature or derate the output. Long-term: replace the module.
  • A07012 — Motor Module current limit active: Not a module fault per se, but if this alarm appears immediately after installing a replacement 6SL3760-0BG00-1AA0, verify that the motor data set in the Control Unit matches the connected motor. DRIVE-CLiQ auto-identification (p0010=1, p0015=1) will re-read motor encoder data — run this after every Power Module swap.

Replacement procedure — field checklist:

  • De-energize the drive system and wait a minimum of 5 minutes for DC bus capacitors to discharge. Measure with a calibrated meter before touching busbars — do not trust the LED indicators alone.
  • Disconnect DRIVE-CLiQ cables and label them. On multi-axis systems, cable routing errors after reassembly are a leading cause of post-replacement faults.
  • Note the DIP switch settings on the outgoing module if any are present (topology-dependent). The 6SL3760-0BG00-1AA0 does not use address DIP switches — addressing is handled automatically via DRIVE-CLiQ topology recognition. No manual switch configuration is required.
  • After installing the replacement unit, power up the Control Unit first. Allow DRIVE-CLiQ topology scan to complete (typically 30–60 seconds). The CU will auto-assign the new module. If the system was previously saved with a specific topology, you may receive A01007 (topology mismatch) — accept the new topology via p9906 or STARTER/TIA Portal.
  • Verify firmware compatibility. The 6SL3760-0BG00-1AA0 firmware must be compatible with your Control Unit firmware version. Check p0018 on the CU and cross-reference with the Siemens SINAMICS S120 firmware compatibility matrix. Mismatched firmware is a silent killer — the system may appear to run but exhibit intermittent faults under load.
  • Run a motor identification routine (p1910) before returning the axis to production. This recalibrates current controller gains to the actual motor connected.

Reliability in Harsh Conditions

The SINAMICS S120 platform was not designed for climate-controlled server rooms. It was engineered for the floor — where coolant mist settles on cabinets, where forklift vibration travels through concrete into your drive rack, where summer ambient temperatures in non-air-conditioned facilities push 45 °C before noon.

The 6SL3760-0BG00-1AA0 is rated IP20, which means it relies on the enclosure for environmental protection. What matters is what’s inside: Siemens specifies the power electronics to IEC 60068-2 vibration and shock standards, with sinusoidal vibration tolerance up to 0.075 mm displacement at 10–58 Hz and 1g acceleration at 58–500 Hz. The conformal coating on the PCB assemblies provides a meaningful barrier against condensation and airborne contaminants — a detail that separates genuine Siemens hardware from counterfeit units that fail within months in the same conditions.

Every unit we ship has been stored in a climate-controlled warehouse in Xiamen. Anti-static bags, foam-lined cartons, and humidity indicator cards are standard. We do not stack drive modules. We do not ship without corner protection. If it arrives damaged, we make it right — no argument.

Global Express Logistics

Our warehouse is in Xiamen, Fujian — one of China’s primary export hubs with direct DHL Express and FedEx International Priority gateway access. Here’s how a typical urgent shipment moves:

  • Order confirmed before 15:00 CST: Same-day pick, pack, and handover to DHL/FedEx.
  • Export documentation: Commercial invoice, packing list, and HS code declaration (HS 8537.10 for drive control modules) prepared in-house. No delays waiting for a freight forwarder to generate paperwork.
  • Transit times (typical, not guaranteed): Southeast Asia 1–2 days, Europe 3–5 days, North America 3–5 days, Middle East 3–4 days, South America 5–7 days.
  • Tracking: AWB number sent via email and WhatsApp within 2 hours of pickup scan. We monitor shipments and proactively flag any customs holds.
  • Customs value declaration: Accurate and compliant. We do not under-declare to save you import duty — that creates delays and liability that cost more than the duty itself.
  • Import duty responsibility: DAP (Delivered At Place) is our standard Incoterm. DDP available on request for select destinations — ask before ordering.

If your plant is in a country with complex import regulations (India, Brazil, Indonesia), contact us before ordering. We have routed shipments through these corridors before and know the documentation requirements.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.