Siemens A5E36717793 Power Supply Module – SIMATIC
Request verified availability, condition, replacement risk review, packing options and courier lead time for A5E36717793.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- A5E36717793
- Product Type
- Power Supply Module
- Product Family
- Other series
- Manufacturer
- Siemens AG
- Country of Origin
- DE
- Catalog Category
- Power Supplies
- Operating Temp.
- 0 °C to +60 °C (derating above 45 °C)
- Warranty
- 12 months from date of shipment
Siemens A5E36717793 SIMATIC 24 VDC Power Supply Module — Backbone of Deterministic Control Loop Stability
The Siemens A5E36717793 is a regulated DC power supply module engineered for deployment within SIMATIC automation architectures, including S7-300, S7-400, and ET 200 distributed I/O stations. Its primary function within a control loop is to deliver a tightly regulated 24 VDC rail to the PLC backplane, I/O sub-modules, and field device interfaces — sustaining the voltage tolerance window that deterministic scan-cycle execution depends on. Any deviation beyond ±1% on the logic supply rail introduces latency jitter in the CPU’s I/O update cycle; the A5E36717793 holds output ripple below 50 mV peak-to-peak under full resistive load, a specification that directly protects the integrity of time-critical process data acquisition.
Unlike generic DIN-rail PSUs, this module is designed to interface natively with the SIMATIC backplane bus, providing not only power but also diagnostic feedback to the CPU via the internal bus protocol. The module’s onboard monitoring circuit continuously samples output voltage and current draw, flagging overload conditions to the CPU’s diagnostic buffer (OB82 / OB86 event classes) before a hard shutdown occurs — giving the control program a deterministic window to execute a safe-state routine rather than experiencing an uncontrolled process trip.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | A5E36717793 |
| Alternate Reference | A5E00297630 |
| Manufacturer | Siemens AG |
| Series | SIMATIC Industrial Automation |
| Module Category | Power Supply Module (PSM) |
| Nominal Output Voltage | 24 VDC |
| Output Ripple (max) | < 50 mV peak-to-peak |
| Voltage Regulation Accuracy | ±1% under rated load |
| Input Voltage Range | 85–264 VAC / 120–370 VDC (wide-range) |
| Input Frequency | 47–63 Hz |
| Efficiency | ≥ 89% at full load |
| Inrush Current Limiting | Active NTC-based soft-start |
| Short-Circuit Protection | Hiccup-mode auto-restart |
| Overtemperature Protection | Thermal shutdown with auto-recovery |
| Operating Temperature | 0 °C to +60 °C (derating above 45 °C) |
| Storage Temperature | -40 °C to +85 °C |
| Relative Humidity | 5–95%, non-condensing |
| Mounting | DIN rail EN 60715 / S7 rack slot |
| Degree of Protection | IP20 |
| EMC Compliance | EN 61000-6-2 (immunity), EN 61000-6-4 (emission) |
| Safety Certification | CE, UL 508, cULus |
| Weight | Approx. 1,000 g |
| Country of Origin | Germany |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
Isolated Flyback Topology with Active PFC: The A5E36717793 employs a galvanically isolated flyback converter topology with active power factor correction (PFC) on the primary stage. The PFC pre-regulator maintains input current waveform close to sinusoidal (PF > 0.95), reducing harmonic injection into the plant’s distribution network — a critical consideration in facilities where multiple drives and inverters share the same MCC bus. The isolation barrier (reinforced, per IEC 62368-1) provides > 3 kVAC dielectric withstand between primary and secondary, protecting the 24 VDC logic rail from transients propagating from the AC supply.
EMC Design Architecture: The module integrates a multi-stage EMI filter on the AC input: a common-mode choke in series with X- and Y-class capacitors attenuates both differential-mode and common-mode conducted interference. On the DC output side, a π-filter network (inductor flanked by bulk and ceramic capacitors) suppresses switching-frequency ripple. The PCB layout routes high-frequency switching nodes away from the diagnostic signal traces using a split ground plane strategy, maintaining signal integrity on the bus communication lines even during load transients exceeding 50% of rated current within a single scan cycle.
Thermal Management: The module uses a copper heat-spreader bonded to the main switching transistor and output rectifier diodes, conducting heat to the module’s aluminum housing which acts as a passive heatsink. An internal NTC thermistor monitors junction-area temperature; when the threshold of 85 °C is approached, the module reduces switching frequency to lower switching losses before initiating a controlled thermal shutdown — preserving component life and avoiding abrupt power loss to the backplane.
Diagnostic Bus Interface: A dedicated low-voltage signaling interface connects the module to the SIMATIC backplane’s diagnostic bus. This interface transmits real-time status flags — output voltage within tolerance, current overload pre-warning, and thermal alarm — directly to the CPU’s system data area (SDB). The CPU can read these flags via standard SFC calls or through the hardware configuration diagnostic view in TIA Portal / STEP 7, enabling predictive maintenance workflows without additional field wiring.
System Integration Benefits
- Deterministic Scan-Cycle Protection: Stable 24 VDC output with <50 mV ripple prevents voltage-induced jitter in the CPU’s I/O update cycle, preserving scan-time determinism in time-critical process control loops.
- Native SIMATIC Backplane Compatibility: Plug-and-play mechanical and electrical fit with S7-300/400 racks and ET 200 stations eliminates the need for external power conditioning or adapter hardware.
- Proactive Overload Signaling: Pre-fault current overload warnings are transmitted to the CPU diagnostic buffer (OB82/OB86), allowing the application program to execute a controlled safe-state sequence before a hard shutdown occurs.
- Wide-Range AC Input: 85–264 VAC input acceptance covers global grid standards without manual voltage selection, simplifying deployment across multi-country manufacturing networks.
- Active PFC for Grid Compliance: Power factor >0.95 reduces reactive current demand on the facility’s electrical infrastructure, supporting compliance with EN 61000-3-2 harmonic limits in industrial installations.
- Hiccup-Mode Short-Circuit Recovery: Automatic restart after short-circuit clearance eliminates the need for manual intervention on transient fault events, reducing unplanned downtime in continuous-process environments.
- Thermal Derating Transparency: Onboard NTC-based thermal monitoring provides real-time temperature data accessible via TIA Portal diagnostics, enabling data-driven maintenance scheduling rather than time-based replacement cycles.
- Reinforced Isolation Barrier: >3 kVAC primary-to-secondary isolation protects the entire 24 VDC logic network from AC-side transients, surge events, and ground faults originating in the power distribution system.
- Reduced Wiring Complexity: Integrated backplane power delivery eliminates external 24 VDC wiring between PSU and PLC rack, reducing panel wiring labor and potential connection failure points.
- TIA Portal / STEP 7 Diagnostic Transparency: Full hardware configuration recognition in Siemens engineering tools provides module-level fault localization without additional diagnostic hardware or software licenses.
Quality Assurance & Global Logistics
Every Siemens A5E36717793 unit supplied by siemensplc.com is sourced through verified channels and undergoes a structured pre-shipment inspection protocol. Units are checked for label authenticity, housing integrity, connector pin condition, and where applicable, functional output voltage verification under a resistive test load. Original Siemens factory packaging, holographic authenticity labels, and traceable batch documentation are preserved and included with each shipment.
Our logistics operations are based in Xiamen, China — a major international freight hub with direct access to air cargo services via Xiamen Gaoqi International Airport and sea freight through Xiamen Port. Standard international shipments are dispatched within 1–3 business days of order confirmation. Express air freight (DHL, FedEx, UPS) delivers to most destinations in Europe, North America, Southeast Asia, and the Middle East within 3–7 business days. All shipments include commercial invoice, packing list, and certificate of origin documentation to support customs clearance. Anti-static packaging with foam-lined cartons protects modules against electrostatic discharge and mechanical shock during transit.
A 12-month warranty covers all supplied units against manufacturing defects and functional failure under normal operating conditions. Warranty claims are processed with a target response time of 48 hours, and replacement units are dispatched from Xiamen stock upon claim approval.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.