Siemens SC203-100A-002IR-010-01K-05 Signal Conditioner – SC200 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for SC203-100A-002IR-010-01K-05.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Siemens
- Primary Part Number
- SC203-100A-002IR-010-01K-05
- Product Type
- Signal Conditioner
- Series / Family
- al Conditioner SC200 Series
- Country of Origin
- DE
- Catalog Category
- Industrial Automation Spares
- Operating Temp.
- −20 °C to +60 °C
- Warranty
- 12 months from date of dispatch
SC203-100A-002IR-010-01K-05 — Galvanically Isolated Analog Signal Conditioner for Process Control Loops
The Siemens SC203-100A-002IR-010-01K-05 is a DIN-rail-mounted analog signal conditioner belonging to the SC200 product family. Its primary function within a control loop is to receive a raw field-side analog signal — typically a 4–20 mA current loop or a 0–10 V voltage source — and deliver a galvanically isolated, noise-attenuated replica to the controller-side analog input. This decoupling is not cosmetic: in industrial environments where field instruments share common ground references with variable-frequency drives, solenoid valves, or high-current motor starters, ground potential differences of several volts are routine. Without 3-way isolation, these potentials appear as common-mode noise on the signal conductor, degrading ADC resolution at the PLC input card and introducing measurement offsets that accumulate across the process. The SC203-100A-002IR-010-01K-05 eliminates this failure mode at the panel wiring level, before the signal reaches any controller hardware.
The module is rated for continuous operation across an ambient temperature range of −20 °C to +60 °C and carries CE and RoHS certification, making it suitable for deployment in both European and export-market control panels without additional compliance work. Its 17.5 mm profile allows high-density channel packing on standard 35 mm DIN rail, and plug-in screw terminal blocks permit module replacement without disturbing field wiring — a maintenance characteristic that directly reduces mean time to repair (MTTR) in production environments.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Value |
|---|---|
| Part Number / SKU | SC203-100A-002IR-010-01K-05 |
| Series | SC200 |
| Brand | Siemens |
| Product Type | Analog Signal Conditioner |
| Input Signal | 4–20 mA / 0–10 V DC (configurable) |
| Output Signal | 4–20 mA / 0–10 V DC isolated analog |
| Isolation Type | 3-way galvanic (Input / Output / Power supply) |
| Isolation Voltage | ≥ 1,500 V AC (channel-to-channel) |
| Supply Voltage | 24 V DC ± 10% |
| Current Consumption | ≤ 40 mA at 24 V DC (nominal load) |
| Accuracy | ± 0.1% of full-scale span |
| Temperature Coefficient | ≤ 50 ppm/°C |
| Response Time | ≤ 10 ms (10–90% step response) |
| Operating Temperature | −20 °C to +60 °C |
| Storage Temperature | −40 °C to +85 °C |
| Protection Rating | IP20 (IEC 60529) |
| Mounting | 35 mm DIN rail (EN 60715) |
| Housing Width | 17.5 mm |
| Dimensions (W × H × D) | 17.5 × 99 × 114.5 mm |
| Weight | approx. 500 g |
| Terminal Type | Plug-in screw terminal blocks |
| Certifications | CE, RoHS |
| Country of Origin | Germany |
| Warranty | 12 months from date of dispatch |
Hardware Logical Analysis
The SC203-100A-002IR-010-01K-05 implements a DC/DC converter-based isolation barrier between the field input stage and the output driver stage. The input signal is first conditioned by a precision instrumentation amplifier with a high common-mode rejection ratio (CMRR), typically exceeding 100 dB at 50/60 Hz. This front-end stage suppresses power-line-frequency interference that couples into long field cable runs — a persistent problem in plants where signal cables share conduit with 400 V AC power conductors.
The isolated DC/DC power stage uses a high-frequency transformer operating above 100 kHz, which keeps the transformer core physically small (contributing to the 17.5 mm form factor) while maintaining sufficient energy transfer for the output driver. The output stage reconstructs the analog signal using a precision voltage-to-current or current-to-voltage converter, depending on the configured output mode, with a feedback loop that maintains output accuracy independent of load impedance variations within the rated range.
EMC performance is achieved through a combination of design measures: the PCB layout routes high-frequency switching nodes away from the analog signal path; decoupling capacitors are placed at each power rail entry point; and the housing provides a degree of electrostatic shielding. The module meets the EMC requirements of EN 61326-1 for industrial environments, which includes immunity to electrostatic discharge (ESD), radiated RF fields, electrical fast transients (EFT/Burst), and conducted disturbances — the four most common interference mechanisms in switchgear cabinets.
The plug-in terminal block design deserves specific attention from a maintenance engineering perspective. The terminal block carries the field wiring; the module body plugs into it. When a module requires replacement, the terminal block remains wired and in place. The replacement module is inserted in under 30 seconds without any tools or rewiring. This architecture eliminates the risk of wiring errors during maintenance and reduces the skill level required for field replacement.
System Integration Benefits
- Ground loop elimination at source: 3-way galvanic isolation with ≥ 1,500 V AC barrier prevents ground potential differences from appearing as measurement offsets at the PLC analog input, preserving ADC accuracy across the full 12- or 16-bit input range.
- Deterministic signal latency: Response time ≤ 10 ms ensures that fast process variables — such as pressure transients or flow surges — are faithfully represented at the controller input within the PLC scan cycle, supporting closed-loop control with cycle times down to 20 ms.
- High-density panel design: The 17.5 mm width allows 57 channels per metre of DIN rail, reducing panel footprint and associated enclosure costs in multi-loop installations.
- Zero-rewiring module swap: Plug-in terminal blocks decouple field wiring from the module body, reducing MTTR to under two minutes and eliminating wiring-error risk during corrective maintenance.
- Wide ambient temperature tolerance: Operation from −20 °C to +60 °C covers outdoor enclosures in temperate climates and non-air-conditioned machine rooms without derating, reducing the need for panel climate control equipment.
- Universal signal compatibility: Configurable 4–20 mA and 0–10 V input/output modes allow a single module type to interface with the majority of field transmitters and PLC analog input cards, simplifying spare-parts inventory management.
- Low power consumption: ≤ 40 mA at 24 V DC (≤ 960 mW per channel) reduces the load on the panel 24 V DC power supply bus, allowing more channels to be powered from a single supply rail without upsizing the PSU.
- Regulatory compliance pre-certified: CE and RoHS certification eliminates the need for additional compliance testing when integrating the module into CE-marked machinery or equipment destined for EU markets, accelerating time-to-market for OEM panel builders.
- High measurement accuracy: ± 0.1% full-scale accuracy with a temperature coefficient of ≤ 50 ppm/°C maintains signal fidelity across the operating temperature range, supporting process control applications where measurement drift directly affects product quality or safety margins.
- Broad controller compatibility: The standardized 4–20 mA and 0–10 V output signals are accepted by analog input modules from Siemens S7-300/400/1500, Rockwell ControlLogix/CompactLogix, Schneider Modicon M340/M580, ABB AC500, and any other controller with standard analog inputs — no proprietary interface required.
Quality Assurance & Global Logistics
Every SC203-100A-002IR-010-01K-05 unit dispatched from our Xiamen facility is sourced through verified supply channels and undergoes a pre-shipment inspection covering label integrity, part number and date code verification, and visual condition assessment. Units showing any sign of repackaging, relabeling, or physical damage are quarantined and excluded from sale. A 12-month warranty against manufacturing defects is included with every unit, covering failure under normal operating conditions as defined by the published specification.
Logistics operations are managed from Xiamen, China — a major port city with direct access to international express carriers and freight forwarders. Standard dispatch lead time for in-stock units is 1–3 business days. Shipping options include DHL Express (3–7 business days to most destinations), FedEx International Priority, UPS Worldwide Express, and economy air freight (7–15 business days) for cost-sensitive orders. Full export documentation — commercial invoice, packing list, and certificate of origin — is provided with every shipment to support customs clearance. For bulk orders, sea freight (LCL and FCL) is available on request with competitive transit times to major Asian, European, and North American ports.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
📍 Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.