UniOP ePCL400-9207-30-10-00-10-00-00-00-00 HMI Panel – ePCL400 Series
Request verified availability, condition, replacement risk review, packing options and courier lead time for ePCL400-9207-30-10-00-10-00-00-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- UniOP
- Primary Part Number
- ePCL400-9207-30-10-00-10-00-00-00
- Product Type
- HMI Operator Panel
- Product Family
- Other series
- Country of Origin
- China (distributed via Xiamen)
- Catalog Category
- HMI Panels
- Operating Temp.
- 0 °C to +50 °C
- Warranty
- 12 months against manufacturing defects from date of shipment
UniOP ePCL400-9207-30-10-00-10-00-00-00-00 — Operator Interface Node in Closed-Loop Control Architecture
The ePCL400-9207-30-10-00-10-00-00-00-00 is a configurable industrial HMI operator panel from UniOP’s ePCL400 platform, designed to serve as the primary human-machine interface node within distributed control loops. Unlike general-purpose display terminals, this unit encodes its hardware configuration directly in the part number: the suffix string 9207-30-10-00-10-00-00-00-00 defines display geometry, backlight type, communication port population, I/O option slots, and front-panel protection rating — all factory-set at the point of manufacture. This deterministic hardware specification eliminates field ambiguity and ensures the panel arrives pre-matched to the target application without post-delivery modification.
Within a control loop, the ePCL400-9207-30-10-00-10-00-00-00-00 occupies the supervisory visualization layer. It receives process variable data from the connected PLC or DCS via its configured serial or Ethernet communication port, renders that data on a high-resolution TFT display, and returns operator commands — setpoint adjustments, mode changes, alarm acknowledgements — back to the controller in real time. The panel’s internal processor handles screen rendering, tag database polling, and communication protocol management concurrently, maintaining display refresh rates that keep pace with fast-changing process states in applications such as servo axis monitoring, batch sequencing, and multi-zone temperature control.
The ePCL400 platform supports a broad driver library covering Siemens S7 (MPI, PROFIBUS, Ethernet), Allen-Bradley DF1 and EtherNet/IP, Mitsubishi FX and Q series, Omron Host Link and FINS, Modbus RTU/TCP, and additional protocols via the UniOP eConfigure software environment. This multi-protocol architecture means the panel can be deployed across heterogeneous control environments without hardware changes — only the communication driver configuration in the project file changes.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number / SKU | ePCL400-9207-30-10-00-10-00-00-00-00 |
| Brand | UniOP (Gefran Group) |
| Series | ePCL400 |
| Product Category | Industrial HMI Operator Panel |
| Display Technology | TFT Color LCD with resistive or capacitive touch overlay (per configuration) |
| Display Size | Determined by position 3 of part number suffix (code 30 = approx. 10.4″ diagonal) |
| Resolution | 640 × 480 (VGA) or 800 × 600 (SVGA) depending on display module |
| Processor | 32-bit RISC embedded CPU |
| Program Memory | Non-volatile Flash; project storage ≥ 4 MB |
| Communication Ports | RS-232, RS-485/422, Ethernet 10/100 (port population per suffix code) |
| Supply Voltage | 24 V DC ± 15% (typical ePCL400 supply range) |
| Power Consumption | ≤ 25 W at nominal voltage |
| Operating Temperature | 0 °C to +50 °C |
| Storage Temperature | −20 °C to +70 °C |
| Relative Humidity | 10 % to 90 % RH, non-condensing |
| Front Panel Protection | IP65 (per suffix code 10 at position 6) |
| Rear Enclosure | IP20 |
| Panel Cutout | Standard ePCL400 cutout dimensions (refer to UniOP installation drawing) |
| Weight | Approx. 1,250 g |
| Certifications | CE, UL (subject to specific configuration) |
| Warranty | 12 months against manufacturing defects from date of shipment |
| Country of Origin | China (distributed via Xiamen) |
Hardware Logical Analysis
The ePCL400-9207-30-10-00-10-00-00-00-00 is built around a 32-bit RISC embedded processor that manages three concurrent execution threads: the display rendering engine, the communication stack, and the tag database manager. These threads operate under a real-time operating system (RTOS) kernel that enforces deterministic scheduling — the communication polling cycle does not starve the display refresh task, and alarm state evaluation runs at a fixed scan rate independent of screen complexity.
EMC Design: The panel’s internal PCB layout separates the high-frequency display driver circuitry from the communication interface section using a ground plane partition. Serial communication lines (RS-232, RS-485) pass through transient voltage suppression (TVS) diode arrays at the connector entry points, providing protection against electrostatic discharge (ESD) up to ±15 kV (contact) per IEC 61000-4-2. The Ethernet port incorporates a transformer-isolated PHY, which eliminates ground loop currents between the panel and the network switch — a common source of communication errors in electrically noisy plant environments.
Backlight and Display Longevity: The TFT backlight assembly uses LED technology with a rated service life exceeding 50,000 hours at nominal operating temperature. The backlight driver circuit includes a thermal derating algorithm: as the internal panel temperature rises above 40 °C, the driver reduces backlight current proportionally to maintain junction temperature within the LED manufacturer’s rated envelope. This extends backlight service life in high-ambient-temperature enclosures without requiring external cooling.
Touch Interface Signal Processing: The resistive touch overlay (where configured) uses a 4-wire analog measurement circuit with a dedicated touch controller IC that performs coordinate averaging over 16 samples per touch event. This averaging filter rejects single-point noise spikes caused by vibration or electrical interference, ensuring that operator touch inputs are registered accurately even on machine tools with significant mechanical vibration at the panel mounting surface.
Non-Volatile Project Storage: The application project — tag database, screen graphics, communication driver configuration — is stored in NOR Flash memory. NOR Flash provides byte-level random read access, which allows the RTOS to execute code directly from Flash without copying it to RAM on startup. This reduces boot time and eliminates the risk of project data corruption from power interruptions during RAM-to-Flash write cycles.
System Integration Benefits
- Deterministic Communication Polling: The ePCL400 communication stack executes tag read/write cycles at a configurable fixed interval (minimum 50 ms), ensuring that process variable updates reach the display within a bounded latency — critical for operator response in fast-process applications such as pressure control and flow regulation.
- Multi-Protocol Driver Library: A single hardware unit supports Siemens S7 (MPI/PROFIBUS/Ethernet), Allen-Bradley DF1/EtherNet/IP, Mitsubishi FX/Q, Omron FINS, Modbus RTU/TCP, and additional protocols — reducing spare parts inventory and training overhead in multi-vendor plant environments.
- Alarm Management with Timestamping: The panel maintains an alarm history buffer with RTC-based timestamps (resolution: 1 second). Alarm records persist through power cycles in non-volatile memory, providing a post-event audit trail without requiring an external historian for basic fault analysis.
- Recipe and Parameter Management: The ePCL400 platform supports recipe data sets stored in Flash, allowing operators to load pre-defined process parameter sets (e.g., product changeover setpoints) directly from the panel without PLC program modification — reducing changeover time in batch manufacturing.
- Trend Display with Data Logging: Real-time trend screens display up to 8 process variables simultaneously with configurable time bases. Logged trend data is stored in circular buffer format in Flash, providing historical process data accessible at the panel without network connectivity.
- Multilingual Screen Support: The eConfigure project environment supports multiple language sets within a single project file. Language switching at runtime is operator-selectable, supporting multinational production facilities without separate panel configurations per language region.
- IP65 Front Panel Sealing: The front panel gasket provides IP65 ingress protection, allowing the panel to be installed in enclosures exposed to wash-down procedures, coolant mist, or dust-laden air without requiring additional protective covers during normal operation.
- Diagnostic Transparency via System Tags: The ePCL400 exposes internal system tags — communication error counters, scan cycle time, backlight hours, and memory utilization — that can be displayed on maintenance screens or logged to the trend buffer. This gives maintenance engineers direct visibility into panel health without connecting a laptop or accessing the eConfigure project.
Quality Assurance & Global Logistics
Every unit of the ePCL400-9207-30-10-00-10-00-00-00-00 supplied through siemensplc.com is sourced from verified supply channels and undergoes a structured pre-shipment verification process at our Xiamen, China facility.
Incoming Inspection: Each panel is inspected against the part number label, packaging integrity, and physical condition upon receipt. Units with damaged packaging, incorrect labeling, or visible physical defects are quarantined and not dispatched.
Functional Verification: Where test equipment is available, panels are powered up and display initialization is confirmed prior to shipment. Communication port continuity is verified using loopback test adapters.
Documentation Package: Each shipment includes the original manufacturer’s documentation where available — datasheet, installation guide, and certificate of conformity. A packing list with serial number and part number is included for customs and receiving inspection.
12-Month Warranty: All units carry a 12-month warranty against manufacturing defects from the date of shipment. Warranty claims are processed via email with photographic evidence of the defect; replacement or repair is arranged within 5 business days of claim approval.
Global Logistics from Xiamen: Shipments are dispatched from Xiamen, China via DHL Express, FedEx International Priority, and UPS Worldwide Expedited. Typical transit times: 3–5 business days to Europe and North America, 2–4 business days to Southeast Asia and the Middle East. All shipments include full tracking and commercial invoice documentation for customs clearance. Export control classification and HS code documentation are provided upon request.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
{
“@context”: “https://schema.org/”,
“@graph”: [
{
“@type”: “Product”,
“name”: “UniOP ePCL400-9207-30-10-00-10-00-00-00-00 Industrial HMI Operator Panel”,
“description”: “UniOP ePCL400-9207-30-10-00-10-00-00-00-00 configurable industrial HMI operator panel from the ePCL400 Series. Multi-protocol communication, IP65 front panel, 12-month warranty. In stock and shipped from Xiamen, China.”,
“sku”: “ePCL400-9207-30-10-00-10-00-00-00-00”,
“mpn”: “ePCL400-9207-30-10-00-10-00-00-00-00”,
“brand”: {“@type”: “Brand”, “name”: “UniOP”},
“manufacturer”: {“@type”: “Organization”, “name”: “UniOP (Gefran Group)”},
“category”: “Industrial HMI Operator Panel”,
“offers”: {
“@type”: “Offer”,
“url”: “https://siemensplc.com”,
“priceCurrency”: “USD”,
“availability”: “https://schema.org/InStock”,
“seller”: {“@type”: “Organization”, “name”: “siemensplc.com”}
}
}
]
}
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.