Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- ABB
- Primary Part Number
- RETA-02
- Product Type
- Fieldbus Communication Adapter
- Series / Family
- S800
- Manufacturer
- ABB Ltd.
- Country of Origin
- SE
- Catalog Category
- Motor Drives
- Humidity
- 5–95% RH, non-condensing
ABB RETA-02 Down? Every Minute of Downtime Costs You Money — We Ship Today
Your ACS800 or ACS550 drive just dropped off the EtherNet/IP network. The line is stopped. Maintenance is on the phone. You already know the RETA-02 adapter is the culprit — the drive is healthy, but the fieldbus link is dead. You need a verified, ready-to-ship replacement, not a 6-week lead time from the OEM distributor.
We stock the ABB RETA-02 in Xiamen and dispatch same-day via DHL Express or FedEx International Priority. From our warehouse to your panel room — typically 2–5 business days, anywhere on the planet. One phone call, one tracking number, line back up.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | RETA-02 ✅ Ready to Ship |
| Manufacturer | ABB Ltd. |
| Series Compatibility | ACS800 (all frame sizes), ACS550, ACS350 (via RDNA-01 slot) |
| Protocol | EtherNet/IP (CIP over TCP/IP) — ODVA compliant |
| Physical Ports | 2 × RJ-45, 10/100 Mbps, auto-negotiation, DLR-capable |
| Topology | Linear, Star, Device Level Ring (DLR) |
| Cyclic I/O | Up to 10 words IN / 10 words OUT (configurable) |
| Acyclic Access | Full parameter R/W via Explicit Messaging (Class 3) |
| IP Assignment | DHCP / BOOTP / Manual (drive panel or EDS tool) |
| Power Source | Drive option slot — no external PSU |
| Operating Temp | -10 °C to +55 °C |
| Storage Temp | -40 °C to +70 °C |
| Humidity | 5–95% RH, non-condensing |
| Protection | IP20 |
| Certifications | CE, UL, cUL, RoHS |
| Firmware | Field-upgradeable via drive control panel |
| EDS File | ABB Library doc: 3AFE68573271 |
| Country of Origin | Finland |
| Stock Status | ✅ In Stock — Ships Same Day |
Troubleshooting & Replacement Tips
Common failure signatures that point to a dead RETA-02:
- Drive runs normally in local control, but EtherNet/IP I/O connection drops (Fault 7.xx or Communication Fault on the PLC side)
- Module LEDs: NS LED solid red or alternating red/green — indicates CIP connection failure or duplicate IP conflict
- MS LED flashing red — module self-test failed, internal hardware fault confirmed
- Drive parameter 98.02 (Comm Module Link) shows “Not Connected” despite cable being live
- PLC I/O tree shows the drive node as “Faulted” with error code 0x0800 (Connection Timeout)
Step-by-step hot-swap procedure (ACS800):
- Power down the drive fully — wait for the DC bus to discharge (minimum 5 minutes, verify with meter)
- Note the existing IP address, subnet mask, and gateway from drive parameter group 51 before removal
- Eject the RETA-02 from option slot 1 or 2 — press the locking tab, slide straight out
- Inspect the slot connector on the drive control board for bent pins or corrosion before inserting the replacement
- Seat the new RETA-02 firmly until the latch clicks — do not force
- Power up the drive; the module will self-initialize. Check parameter 98.02 — it should read “EtherNet/IP”
- Re-enter IP settings via parameter group 51 (or use BOOTP/DHCP if your network assigns addresses automatically)
- Cycle the PLC I/O connection — inhibit and re-enable the drive’s EtherNet/IP node in your scanner configuration
- Verify NS LED goes solid green (online, connected) and MS LED goes solid green (module healthy)
- Run a short jog command from the PLC to confirm cyclic data exchange before returning to production
Critical configuration notes engineers miss:
- IP Conflict: If the old module had a static IP, the replacement will default to DHCP. Your PLC will not find it until you reassign the same static address. Always document the IP before pulling the old module.
- Firmware mismatch: RETA-02 firmware must be compatible with the drive’s RMIO board firmware. Check ABB’s compatibility matrix (document 3AFE68573271). Mismatched firmware causes intermittent connection drops that look like network issues.
- DLR ring break: If you’re running a Device Level Ring and you pull the RETA-02 without first breaking the ring at the supervisor, the ring will fault. Disable DLR at the PLC scanner before swapping.
- EDS file version: After firmware update, re-import the matching EDS file into your PLC project. Stale EDS files cause assembly instance mismatches and cryptic connection errors.
- ACS550 slot orientation: The ACS550 uses a different option slot form factor than the ACS800. Confirm your drive model before ordering — RETA-02 fits both, but the mechanical slot on ACS350 requires the RDNA-01 carrier board.
Reliability in Harsh Conditions
The RETA-02 was not designed for a climate-controlled server room. ABB engineered it for the slot inside a VFD cabinet — an environment that sees motor switching transients, conducted EMI from IGBT switching at 4–16 kHz, thermal cycling from drive load changes, and the vibration of a machine running 24/7.
The PCB uses conformal coating on critical signal traces, providing resistance to condensation in high-humidity environments such as food processing washdown areas and coastal installations. The RJ-45 connectors are rated for industrial vibration profiles consistent with IEC 60068-2-6 (sinusoidal vibration) and IEC 60068-2-27 (shock). Operating temperature ceiling of +55 °C means the module survives inside a panel where ambient air temperature can spike during summer production peaks without thermal throttling or data corruption.
Units we ship have been stored in controlled warehouse conditions (temperature 15–25 °C, humidity 40–60% RH) and inspected for electrostatic discharge damage before dispatch. Every board is handled with ESD precautions from our shelf to your door — anti-static bag, foam padding, and a rigid outer carton rated for international air freight handling.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian — one of China’s primary export ports with direct DHL and FedEx gateway access. Here is exactly what happens after you confirm your order:
- Same day (orders before 15:00 CST): Unit pulled from stock, inspected, photographed, packed in anti-static bag + foam insert + double-wall carton. Commercial invoice and packing list prepared with accurate HS code (8537.10) for smooth customs clearance.
- Day 1: DHL Express or FedEx International Priority pickup from our facility. Tracking number sent to your email within 2 hours of handover.
- Day 2–3: Clears Xiamen customs and transits through DHL/FedEx regional hub (typically Hong Kong or Shanghai gateway).
- Day 3–5: Delivery to your door in Europe, North America, Southeast Asia, Middle East, or Australia. Remote locations may add 1–2 days.
- Import duties: We declare accurate commercial value. For EU buyers, we can provide EUR-1 or origin certificates on request to support preferential tariff claims where applicable.
- Emergency freight: For genuine production-down situations, ask about next-flight-out courier options. We have handled shipments that cleared customs and reached the plant floor within 36 hours of order confirmation.
We do not use postal services or economy freight for industrial spare parts. Your downtime cost per hour almost certainly exceeds the freight premium for express shipping — we treat every order as if the line is stopped, because often it is.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.