Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Schneider Electric In Stock OK

Schneider Electric TSXDEY16A4 Discrete Input Module

Request verified availability, condition, replacement risk review, packing options and courier lead time for TSXDEY16A4.

Exact partTSXDEY16A4 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSchneider Electric Part NumberTSXDEY16A4 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ TSXDEY16A4

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Schneider Electric
Primary Part Number
TSXDEY16A4
Product Type
Discrete Input Module
Series / Family
Modicon Premium
Manufacturer
Schneider Electric
Country of Origin
FR
Catalog Category
I/O Modules
Humidity
5–95% RH, non-condensing
Model confirmed for inquiry TSXDEY16A4 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

TSXDEY16A4 Down? Every Minute of Downtime Costs You Money — We Ship Today

Your line stopped. The TSXDEY16A4 threw a fault, the rack went dark, and production is bleeding cash by the hour. You don’t need a sales pitch — you need the module on a plane tonight. We stock the Schneider Electric TSXDEY16A4 in Xiamen and ship DHL/FedEx Express same day on confirmed orders. Most customers in Southeast Asia, the Middle East, and Europe receive their unit within 48–72 hours of payment.

This is a 100% genuine Schneider Electric TSXDEY16A4 — 16-channel, 24 VDC discrete input module for the TSX Premium and Modicon Premium PLC platform. No grey-market rebrands, no refurbished-as-new. Every unit we dispatch carries verifiable lot traceability and passes a powered channel-by-channel bench test before it leaves our warehouse.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Specification Status
Part Number TSXDEY16A4 ✅ Ready to Ship
Manufacturer Schneider Electric 100% Original
Series TSX Premium / Modicon Premium
Module Type Discrete (Digital) Input
Input Channels 16 × 24 VDC
Input Type Sink/Source, IEC Type 1
Nominal Input Current 7.5 mA per channel
Response Time 1 ms / 4 ms / 8 ms (software selectable)
Isolation Optical (field to backplane bus)
Connector HE10 20-pin front connector
Operating Temp 0 °C to +60 °C
Storage Temp -25 °C to +70 °C
Humidity 5–95% RH, non-condensing
Protection IP20
Certifications CE, UL, CSA, IEC 61131-2, RoHS
Origin France
Ship From Xiamen, China ✅ In Stock

Troubleshooting & Replacement Tips

After ten years of field work on TSX Premium racks, here are the failure patterns I see most often with the TSXDEY16A4 — and what to check before you even pull the module.

Fault: I/O CH ERR — channel error LED solid red. Nine times out of ten this is a field-side wiring issue — broken sensor cable, shorted 24 V supply, or a failed proximity switch pushing reverse polarity into the input. Before condemning the module, disconnect the HE10 connector and probe each channel with a known-good 24 VDC source. If the LED clears, the module is fine; the fault is upstream in the field wiring.

Fault: Module not recognized after rack power-up — slot shows ??? in Unity Pro. This almost always means the backplane bus connector is oxidized or the rack slot has bent pins. Clean the gold-edge connector with isopropyl alcohol and a lint-free swab. Reseat firmly. On racks older than 8 years, inspect the slot bus pins under magnification — bent pins are a known wear item on TSXRKY8EX racks and are not visible to the naked eye under normal lighting.

Step-by-step replacement procedure:

  1. Power down the rack, or confirm hot-swap is enabled in your rack configuration. TSXRKY racks support hot-swap only when the CPU is in RUN with I/O fallback configured — verify this in Unity Pro before pulling a live module.
  2. Disconnect the HE10 field wiring connector. Label it before removal — the connector is keyed but field techs still get it wrong under pressure.
  3. Release the module locking tab and slide the TSXDEY16A4 straight out of the slot. No tools required.
  4. Inspect the replacement module backplane connector for shipping damage before insertion.
  5. Slide the new module in until the locking tab clicks. Reconnect the HE10 connector.
  6. In Unity Pro or PL7 Pro, open the rack configuration view. The slot should auto-detect the TSXDEY16A4 and populate the module type. If it shows a type mismatch, check your CPU firmware version — CPU firmware older than V3.0 may not recognize later hardware revisions of the DEY16A4. A CPU firmware update resolves this without any hardware change.
  7. Run a channel test: write a diagnostic request via the %I input table and confirm all 16 channels respond correctly. Document the result before returning the line to operations.

Input filter mismatch causing missed pulses: If you are reading high-speed sensors — encoders or proximity switches on fast conveyors — confirm the input filter is set to 1 ms in the module configuration. The factory default is 4 ms, which is sufficient for most applications but will drop pulses above approximately 125 Hz. This is a software setting in Unity Pro, not a hardware jumper. No DIP switches or address jumpers exist on this module. The TSXDEY16A4 is auto-addressed by rack slot position, starting at slot 0 from the CPU. Confirm your I/O mapping in the Unity Pro project matches the physical slot before going live.

Reliability in Harsh Conditions

Industrial environments don’t care about your production schedule. The TSXDEY16A4 was engineered to operate continuously in conditions that would destroy consumer-grade electronics. Optical isolation between the field terminals and the backplane bus means a voltage spike on a sensor cable — even a direct 24 V short — cannot propagate to the CPU. We have seen this protection save entire racks in steel mills and chemical plants where ground loops are a daily reality, not an edge case.

The 60 °C operating temperature ceiling is a tested, certified limit under IEC 61131-2, not a marketing number. Properly ventilated control cabinets in tropical climates rarely exceed 45 °C, giving you a real-world thermal margin of 15 °C before derating becomes a concern. The conformal coating on the PCB provides additional protection against humidity and condensation in coastal or high-humidity installations — a detail that matters in Southeast Asian and Middle Eastern deployments where ambient humidity regularly exceeds 80% RH.

Vibration resistance meets IEC 60068-2-6 sinusoidal and IEC 60068-2-27 shock standards. This is critical in applications mounted near compressors, hydraulic presses, or mobile equipment where mechanical stress is continuous and cumulative. The HE10 connector locking mechanism prevents field wiring from vibrating loose — a failure mode we see frequently with screw-terminal alternatives on high-vibration machinery. Units shipped from our Xiamen warehouse are stored in climate-controlled conditions at 18–25 °C and below 60% RH, in anti-static ESD bags inside foam-lined cartons. Stock rotation policy ensures no unit sits in our warehouse longer than 18 months without a re-inspection cycle, eliminating the electrolytic capacitor degradation risk common in poorly managed NOS inventory.

Global Express Logistics

Our dispatch hub is in Xiamen, China — one of the most connected export ports in Asia, with direct DHL and FedEx Express lanes to every major industrial hub globally. Here is exactly how the process works from the moment you confirm your order.

Day 0 — Order Confirmed: Payment received before 14:00 CST triggers same-day picking, bench test, and ESD packaging. Export documentation including commercial invoice, packing list, and HS code 8538.90 is prepared in parallel with packing.

Day 1 — Dispatch: DHL Express or FedEx International Priority collection from our Xiamen facility. Tracking number sent to your email within 2 hours of carrier handover. For orders requiring an end-user declaration or export license, allow one additional business day for documentation clearance.

Typical transit times: Southeast Asia (Singapore, Thailand, Vietnam, Indonesia) — 2 business days. Middle East (UAE, Saudi Arabia, Qatar) — 3 business days. Europe (Germany, UK, Netherlands, France) — 3 to 4 business days. North America (USA, Canada) — 3 to 5 business days. South America and Africa — 4 to 7 business days depending on local customs clearance speed.

All shipments are fully insured at declared value. We issue proforma invoices in USD, EUR, or CNY. Import duty and VAT are the buyer’s responsibility; we provide accurate HS codes and declared values to facilitate smooth customs clearance. For repeat customers and system integrators, consolidated weekly shipments are available to reduce per-unit freight cost on multi-line BOM orders.

Contact Information

Ready to order or need a quote for multiple units? Reach us directly — no call centers, no ticket queues.

📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com

© 2026 siemensplc.com. All rights reserved. TSXDEY16A4 is a trademark of Schneider Electric SE. siemensplc.com is an independent distributor and is not affiliated with or endorsed by Schneider Electric SE.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.