Allen-Bradley 2711-T9C1X HMI Terminal – PanelView 900
Request verified availability, condition, replacement risk review, packing options and courier lead time for 2711-T9C1X.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 2711-T9C1X
- Product Type
- HMI Touch Terminal
- Series / Family
- PanelView
- Country of Origin
- US
- Catalog Category
- HMI Panels
- Operating Temp.
- 0 °C to +55 °C (32 °F to 131 °F)
Allen-Bradley 2711-T9C1X: 9-Inch Color Touch HMI Terminal in the PanelView 900 Control Architecture
The Allen-Bradley 2711-T9C1X is a 9-inch color CRT touch screen operator interface terminal belonging to Rockwell Automation’s PanelView 900 series. Operating on a wide-range AC input of 100–240 V at 50/60 Hz, this unit functions as the primary human-machine interface node in discrete manufacturing, process control, and material handling control loops. Its role is not decorative — it is the operator’s sole window into the real-time state of the connected PLC network, translating tag data from DH-485 or RS-232 DF1 communication frames into actionable graphical representations at scan rates governed by the PLC’s output image table update cycle.
In a typical SLC 500 or PLC-5 control loop, the 2711-T9C1X polls the processor’s data table at configurable intervals, renders discrete bit states as pushbutton or indicator graphics, and writes operator inputs back to the output image table via the same serial channel. The terminal’s internal application processor handles screen rendering independently of the PLC scan, ensuring that display refresh does not introduce latency into the control loop. This architectural separation between display processing and control communication is a deliberate design choice that maintains deterministic PLC scan behavior regardless of screen complexity.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Part Number | 2711-T9C1X |
| Brand / OEM | Allen-Bradley (Rockwell Automation) |
| Series | PanelView 900 |
| Display Size | 9 inches (diagonal, CRT color) |
| Input Interface | Resistive touch screen |
| Supply Voltage | 100–240 V AC, 50/60 Hz |
| Power Consumption | Approx. 65 W (typical operating) |
| Communication Ports | RS-232 / RS-422 / DH-485 (port configuration model-dependent) |
| Baud Rate | Up to 19,200 bps (DH-485); up to 19,200 bps (RS-232 DF1) |
| Operating Temperature | 0 °C to +55 °C (32 °F to 131 °F) |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5–95% non-condensing |
| Enclosure Rating (front) | NEMA 4 / 4X / 12 / 13; IP65 equivalent |
| Panel Cutout Dimensions | Approx. 310 mm × 248 mm (W × H) |
| Unit Weight | Approx. 3.6 kg |
| Programming Software | PanelBuilder 1400e / RSView ME (for migration) |
| Memory (application) | Non-volatile flash; application retained on power loss |
| Certifications | UL Listed, CE Marked, CSA Certified, Class I Div 2 (selected variants) |
| Warranty (supplied by us) | 12 months from shipment date |
Hardware Logical Analysis
The 2711-T9C1X is built around a dedicated display controller ASIC that manages CRT raster scanning independently of the communication co-processor. This dual-processor architecture means the serial communication stack — handling DH-485 token-passing or RS-232 DF1 full-duplex framing — operates on its own interrupt-driven execution context. The result is that a momentary spike in screen redraw activity (e.g., a full-screen alarm page transition) does not delay the acknowledgment of incoming PLC data packets, preserving the integrity of the polling cycle.
The RS-232 port implements hardware flow control via RTS/CTS lines, which is critical in electrically noisy panel environments where software flow control (XON/XOFF) can be corrupted by EMI-induced bit errors. The DH-485 port uses a balanced differential signal pair (±5 V swing) with a characteristic impedance of 120 Ω, providing inherent common-mode noise rejection of up to 7 V — sufficient to suppress the ground potential differences commonly encountered between panel enclosures and field device cabinets in large industrial facilities.
The front panel bezel is constructed from a polycarbonate/ABS composite rated to withstand repeated solvent wipe-downs without surface crazing, a requirement in food processing and pharmaceutical environments. The resistive touch overlay uses a four-wire analog matrix that remains operable with gloved hands and is immune to the false-touch events that capacitive overlays can generate in high-humidity or condensation-prone environments. The CRT phosphor is a P22 triad type, selected for its color gamut stability across the 0–55 °C operating range without requiring active thermal compensation of the deflection yoke.
Internal EMC design follows IEC 61000-4 series test criteria. The power supply section incorporates a common-mode choke on the AC input line, a transient voltage suppressor (TVS) rated at 1.5 kW peak pulse power, and a π-filter capacitor network to attenuate conducted emissions below CISPR 11 Class A limits. This ensures the terminal does not inject switching noise back onto the facility power bus — a non-trivial concern in plants where HMI terminals share distribution panels with variable-frequency drives.
System Integration Benefits
- Zero-modification panel retrofit: The 2711-T9C1X shares the same panel cutout geometry as earlier PanelView 550 and 600 units in the same enclosure family, allowing direct mechanical substitution without re-machining the panel door.
- Native DH-485 token-passing support: The terminal participates in the DH-485 network as a standard node, eliminating the need for protocol converters or gateway devices when connecting to SLC 500 processors — reducing BOM cost and eliminating an additional failure point.
- Application file portability: PanelBuilder 1400e project files (.PBA) transfer directly to the terminal via the RS-232 programming port without requiring a dedicated programming adapter, shortening commissioning time to under 15 minutes for a pre-tested application.
- Deterministic display update: The terminal’s internal polling rate is configurable from 100 ms to 10,000 ms per tag group, allowing engineers to prioritize high-frequency alarm tags over low-priority status displays without increasing PLC communication load.
- Alarm management with latching logic: The built-in alarm subsystem supports latched alarm acknowledgment, ensuring that transient fault conditions that clear before the operator responds are still captured in the alarm history buffer — a requirement under IEC 62682 alarm management guidelines.
- Multi-language display capability: The “X” suffix variant includes extended character set support for European languages (Latin-1 extended), enabling deployment in multinational facilities without application duplication.
- Diagnostic transparency via data table access: The terminal can display raw integer and floating-point values directly from the PLC data table (N, F, T, C file types) without requiring custom ladder logic, reducing the engineering effort needed to build diagnostic screens.
- NEMA 4X front-panel sealing: The IP65-equivalent gasket seal allows the terminal to be installed in outdoor enclosures or washdown zones without additional protective covers, expanding the range of deployable environments beyond typical office-grade HMI products.
Quality Assurance & Global Logistics
Every Allen-Bradley 2711-T9C1X unit supplied by our team is sourced from verified OEM-authorized distribution channels or traceable surplus inventory with documented chain of custody. Before dispatch, each unit undergoes a structured pre-shipment inspection protocol: AC power-on verification at 100 V and 240 V input, display uniformity check across the full CRT raster, touch calibration verification at nine screen zones, and RS-232 loopback communication test at 9,600 bps and 19,200 bps. Serial numbers and firmware revision levels are recorded against each order for full traceability.
Units are packaged in anti-static ESD bags, nested in 30 mm closed-cell polyethylene foam, and enclosed in double-wall corrugated export cartons rated to 32 ECT. This packaging configuration is validated to withstand the ISTA 2A vibration and drop test profile applicable to international air and sea freight. Shipments originate from Xiamen, China, with access to direct air freight lanes to major industrial hubs including Frankfurt, Los Angeles, Dubai, Singapore, and São Paulo. Standard air freight transit times are 3–7 business days to most destinations. DHL Express, FedEx International Priority, and UPS Worldwide Express are available as carrier options. All export documentation — commercial invoice, packing list, and certificate of origin — is prepared in compliance with destination country customs requirements. A 12-month replacement warranty is provided from the shipment date; defective units are replaced at no charge with prepaid return freight on confirmed warranty claims.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.