Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 2711P-RW2
- Product Type
- HMI Storage Media
- Series / Family
- PanelView
- Manufacturer
- Allen-Bradley / Rockwell Automation
- Country of Origin
- US
- Catalog Category
- HMI Panels
- Operating Temp.
- 0 °C to +55 °C (IEC 60068-2-1 / IEC 60068-2-2)
- Warranty
- 12 months from date of shipment
Allen-Bradley 2711P-RW2 Compact Flash Card — Internal Non-Volatile Storage Architecture for PanelView Plus 6 HMI Terminals
The 2711P-RW2 is a 128 MB internal Compact Flash (CF) card manufactured by Rockwell Automation for exclusive use within the PanelView Plus and PanelView Plus 6 (2711P-series) HMI platform. It occupies the dedicated internal CF slot on the terminal’s main board, functioning as the primary non-volatile storage medium for the FactoryTalk View ME operating system image, operator interface application projects, alarm and event logs, and firmware update packages. Unlike external USB storage, the internal CF slot is electrically isolated from the operator-accessible panel face, reducing the risk of accidental removal during live operation and eliminating the mechanical wear associated with repeated hot-plug cycles on external connectors.
In a PanelView Plus 6 terminal, the boot sequence reads the OS image directly from the CF card via the internal ATA interface. The terminal’s processor — a 400 MHz ARM-based SoC — maps the CF card as a fixed ATA device at initialization, loading the FactoryTalk View ME kernel into RAM before handing off execution to the application layer. This architecture means the 2711P-RW2 is not a peripheral accessory; it is a structural component of the terminal’s operating environment. Substituting a non-OEM CF card introduces risks at the ATA timing layer: commercial CF cards may not conform to the specific read latency and sector-addressing behavior expected by the PanelView Plus 6 BIOS, resulting in boot failures or file-system corruption under thermal stress.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Parameter | Specification |
|---|---|
| Catalog Number | 2711P-RW2 |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Compatible Platform | PanelView Plus (2711P), PanelView Plus 6 (2711P) |
| Storage Capacity | 128 MB |
| Interface | Internal ATA (Compact Flash Type I/II slot) |
| Form Factor | Internal slot-mount; not field-removable during operation |
| Compatible Terminal Families | 2711P-T6xx, 2711P-T7xx, 2711P-T10xx, 2711P-T12xx, 2711P-T15xx |
| Primary Functions | OS image storage, application backup, firmware delivery, data logging |
| Operating Temperature | 0 °C to +55 °C (IEC 60068-2-1 / IEC 60068-2-2) |
| Storage Temperature | −40 °C to +85 °C |
| Relative Humidity | 5% to 95% non-condensing |
| Vibration Resistance | IEC 60068-2-6: 5–500 Hz, 5 g |
| Shock Resistance | IEC 60068-2-27: 30 g, 11 ms half-sine |
| EMC Compliance | CE (EMC Directive 2014/30/EU), FCC Part 15 Class A |
| Safety Certification | UL 508 (Industrial Control Equipment) |
| RoHS Status | Compliant — EU Directive 2011/65/EU |
| Data Retention (unpowered) | >10 years at 25 °C (JEDEC JESD47 endurance model) |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The 2711P-RW2 employs SLC (Single-Level Cell) NAND flash rather than the MLC or TLC densities common in consumer-grade CF cards. SLC flash stores one bit per cell, yielding a rated program/erase (P/E) cycle endurance of approximately 100,000 cycles per block — roughly 10× the endurance of MLC flash at equivalent capacity. For a PanelView Plus 6 terminal logging alarm events at a rate of 500 records per hour across a 24/7 production schedule, the write amplification factor across the 128 MB address space remains well within the SLC endurance envelope over a 10-year service life, assuming standard wear-leveling firmware behavior.
The card’s internal controller implements static wear leveling, distributing write operations across all available erase blocks regardless of logical address locality. This is critical for HMI applications where the OS image occupies a fixed logical address range and would otherwise concentrate P/E cycles on a narrow block set, accelerating localized cell degradation. The controller also maintains a bad-block management table in a reserved area of the flash array, remapping failed blocks transparently to the host ATA interface without exposing errors to the FactoryTalk View ME file system.
From an EMC standpoint, the internal CF slot on PanelView Plus 6 terminals is shielded by the terminal’s steel backplane enclosure, which provides a Faraday cage effect attenuating radiated emissions from the flash controller’s clock harmonics. The 2711P-RW2’s PCB layout routes the ATA data bus with controlled impedance traces (typically 50 Ω differential) to minimize signal reflections at the 33 MHz ATA transfer rate, reducing susceptibility to conducted interference on the data lines. This design discipline is absent in commercial CF cards not validated for industrial ATA environments.
Power consumption of the 2711P-RW2 during active read operations is approximately 100 mA at 3.3 V (330 mW), dropping to under 1 mA in standby. The terminal’s internal power rail supplies this directly from the regulated 3.3 V bus, with no dependency on the external 24 V DC supply beyond the terminal’s own power conversion stage. This means CF card operation is unaffected by transient sags on the 24 V input, provided the terminal’s internal capacitor bank sustains the 3.3 V rail during the sag interval — a design parameter verified in Rockwell Automation’s power-hold-up testing for the 2711P platform.
System Integration Benefits
- Zero-Laptop Field Recovery: A pre-loaded 2711P-RW2 enables a field technician to restore a failed PanelView Plus 6 terminal to full operation by swapping the card into a replacement unit — no programming workstation, no FactoryTalk View ME Studio license required on-site. Boot-to-operational time from card insertion is typically under 90 seconds.
- Deterministic Boot Sequencing: Because the OS image resides on a fixed internal ATA device, the terminal’s BIOS boot order is unambiguous. There is no dependency on network PXE boot or external USB enumeration, eliminating the class of startup failures caused by USB device detection timeouts in cold-start conditions below 5 °C.
- Application Version Control: Each 2711P-RW2 card carries a discrete application image. Maintaining a library of cards with labeled version identifiers provides a physical version-control mechanism for validated HMI applications in FDA 21 CFR Part 11 or GAMP 5 environments, where electronic change control records must be traceable to a specific deployed image.
- Alarm and Event Log Persistence: FactoryTalk View ME can be configured to write alarm logs directly to the CF card’s file system. These logs survive complete power loss without battery backup, unlike SRAM-based retention schemes that depend on a supercapacitor or lithium cell with finite hold-up time.
- Firmware Delivery Without Network Exposure: Rockwell Automation’s recommended method for delivering FactoryTalk View ME OS updates to air-gapped or network-isolated terminals is via CF card. The 2711P-RW2 supports this workflow natively, allowing security-conscious facilities to update HMI firmware without connecting the terminal to a corporate LAN or the internet.
- Reduced Spare-Parts Inventory Complexity: A single 2711P-RW2 card loaded with the correct application image can serve as the spare for any terminal in the same 2711P model family, reducing the number of fully configured spare terminals that must be stocked in the MRO warehouse.
- Diagnostic Transparency: The CF card’s file system is accessible via the terminal’s file manager utility, allowing maintenance personnel to retrieve alarm logs, recipe files, and diagnostic data without specialized software — improving mean time to diagnose (MTTD) for process upsets.
- Compatibility Assurance Across Firmware Revisions: Rockwell Automation validates the 2711P-RW2 against each FactoryTalk View ME firmware release. Using the OEM card eliminates the risk of ATA timing incompatibilities introduced when Rockwell updates the terminal’s BIOS or storage driver, which have been documented to cause boot failures with certain third-party CF cards after firmware upgrades.
Quality Assurance & Global Logistics
Every 2711P-RW2 unit dispatched from our Xiamen, China facility is sourced through verified industrial distribution channels with full lot traceability back to Rockwell Automation’s manufacturing records. Pre-shipment inspection covers catalog number label verification against Rockwell’s published artwork specifications, tamper-evident seal integrity check, date code and lot number cross-reference against known counterfeit advisories published by Rockwell Automation’s Product Security Incident Response Team (PSIRT), and packaging condition assessment to confirm no transit damage prior to the outbound shipment.
Units are packed in anti-static shielding bags with desiccant inserts, placed in rigid foam-lined cartons rated for the vibration and shock profiles of international air freight (ISTA 2A). Export documentation — including commercial invoice, packing list, and certificate of origin — is prepared to DDP (Delivered Duty Paid) Incoterms 2020 on request, simplifying customs clearance for buyers in the EU, North America, Southeast Asia, and the Middle East. Standard dispatch from Xiamen is within 1–2 business days of order confirmation for in-stock units. Air express transit times are typically 3–5 business days to major industrial hubs globally. A 12-month warranty covers defects in materials and workmanship from the date of shipment, with advance replacement available for volume accounts.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.