Allen-Bradley 2711P-T10C4D1/A HMI Terminal – PanelView Plus 1000
Request verified availability, condition, replacement risk review, packing options and courier lead time for 2711P-T10C4D1/A.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Allen-Bradley
- Primary Part Number
- 2711P-T10C4D1/A
- Product Type
- HMI Terminal
- Series / Family
- ControlLogix
- Manufacturer
- Allen-Bradley / Rockwell Automation
- Country of Origin
- US
- Catalog Category
- HMI Panels
- Operating Temp.
- 0 °C to +55 °C (32 °F to 131 °F)
- Warranty
- 12 months from date of shipment
Allen-Bradley 2711P-T10C4D1/A — Operator Interface Architecture for Deterministic Process Control
The 2711P-T10C4D1/A is a 10.4-inch color touch-screen operator terminal within Rockwell Automation’s PanelView Plus 1000 platform. Its role in a control loop is not decorative — it functions as the primary human-to-controller interface layer, translating tag-level data from the backplane into actionable operator displays while simultaneously accepting discrete and analog command inputs that propagate back to the controller via EtherNet/IP or DH-485. The terminal runs FactoryTalk View Machine Edition (ME) on a Windows CE kernel, which provides a deterministic runtime environment for alarm management, recipe execution, and trend logging without the overhead of a general-purpose OS scheduler.
In a typical ControlLogix or CompactLogix architecture, the 2711P-T10C4D1/A sits at the HMI tier, communicating with the controller’s Ethernet port over a dedicated panel LAN. Tag subscriptions are maintained at configurable update rates (typically 250 ms to 1 s), and the terminal’s internal 512 MB Flash storage retains application files, alarm history, and data logs independently of the controller — ensuring operator visibility is preserved even during controller firmware updates or partial network interruptions.
Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345
Technical Parameters
| Part Number | 2711P-T10C4D1/A |
| Series | PanelView Plus 1000 |
| Manufacturer | Allen-Bradley / Rockwell Automation |
| Display Size | 10.4 in (diagonal), active area 211.2 × 158.4 mm |
| Display Technology | Color TFT LCD, analog resistive touch overlay |
| Resolution | 640 × 480 px (VGA), 65,536 colors |
| Backlight Type | CCFL, rated 50,000 hours at 25 °C |
| Processor | Intel PXA270 @ 520 MHz |
| RAM | 128 MB SDRAM |
| Flash Storage | 512 MB internal |
| Operating System | Microsoft Windows CE 5.0 |
| HMI Runtime | FactoryTalk View Machine Edition (ME) |
| Communication — Ethernet | 10/100 Base-T, RJ-45, EtherNet/IP (ODVA conformance tested) |
| Communication — Serial | RS-232 (DB-9), DH-485 (RJ-45) |
| USB Ports | 1× Type A (host), 1× Type B (device/programming) |
| Supply Voltage | 24V DC ±20% (19.2–28.8 V DC) |
| Power Consumption | ≤ 30 W typical |
| Operating Temperature | 0 °C to +55 °C (32 °F to 131 °F) |
| Storage Temperature | −20 °C to +70 °C |
| Relative Humidity | 5–95% non-condensing |
| Ingress Protection (front) | NEMA 4, 4X, 12, 13 / IP65 |
| Vibration | 2 g, 10–500 Hz (IEC 60068-2-6) |
| Shock | 15 g, 11 ms half-sine (IEC 60068-2-27) |
| Certifications | UL 508, cUL, CE (EMC + LVD), RoHS, ODVA EtherNet/IP |
| Panel Cutout | 280 × 216 mm (W × H) |
| Unit Dimensions | 310 × 246 × 72 mm (W × H × D) |
| Weight | Approx. 2.5 kg |
| Warranty | 12 months from date of shipment |
Hardware Logical Analysis
The 2711P-T10C4D1/A is built on a single-board architecture where the Intel PXA270 XScale processor handles both the FactoryTalk View ME runtime and the communication stack concurrently. The XScale core’s memory management unit (MMU) enforces strict process isolation between the HMI application layer and the network driver stack — a design that prevents a runaway display animation or a large trend buffer write from starving the EtherNet/IP I/O scanner of CPU cycles.
Analog Resistive Touch Overlay: The resistive digitizer operates on a four-wire voltage-divider principle. When the operator contacts the overlay, the controller measures the X and Y voltage ratios across the resistive matrix and resolves touch coordinates to within ±2 mm. Unlike capacitive overlays, the resistive layer responds to any stylus or gloved finger, which is operationally significant in environments where operators wear cut-resistant or chemical-resistant gloves.
EMC Design: The chassis is constructed from die-cast aluminum with continuous conductive gaskets at all panel seams. The front bezel integrates a transparent EMI shielding film bonded to the LCD glass, attenuating radiated emissions from the backlight inverter circuit. The 24V DC power input passes through a common-mode choke and transient voltage suppressor (TVS) array rated to absorb 1 kV/1 μs transients per IEC 61000-4-5, making the terminal suitable for installation in panels adjacent to variable-frequency drives (VFDs) and contactors without additional line filtering in most applications.
DH-485 Physical Layer: The RS-485 transceiver on the DH-485 port is isolated from the main logic ground via an optocoupler barrier, providing galvanic isolation up to 500V. This is architecturally important in multi-panel installations where ground potential differences between remote cabinets can introduce common-mode noise that corrupts serial frames. The isolated transceiver eliminates this failure mode without requiring external isolation repeaters.
Flash Wear Leveling: The 512 MB NAND Flash is managed by a firmware-level wear-leveling algorithm that distributes write cycles across the memory array. Alarm history and data log files — which are written at high frequency in active processes — are directed to a dedicated partition with its own wear counter, preventing log activity from accelerating wear on the application partition where the FactoryTalk ME project resides.
System Integration Benefits
- Zero-configuration tag browsing via EtherNet/IP: The terminal’s RSLinx ME communication layer auto-discovers ControlLogix and CompactLogix controllers on the same subnet, populating the tag database without manual address entry — reducing commissioning time on multi-axis or multi-zone systems.
- Alarm management with state persistence: FactoryTalk View ME maintains alarm state (active, acknowledged, cleared) in non-volatile Flash storage. On power restoration after an unplanned outage, the terminal restores the pre-outage alarm queue, giving operators a complete event history without gaps — a requirement in FDA 21 CFR Part 11 and ISA-18.2 compliant installations.
- Recipe management with version control: Up to 1,000 recipe instances can be stored locally. Each recipe write to the controller is executed as an atomic tag-write block, preventing partial recipe downloads that could leave a process in an undefined state between parameter sets.
- Multi-language runtime switching: FactoryTalk View ME supports up to 20 language sets within a single application file. Language switching is executed at runtime without restarting the application, which is operationally relevant in facilities with multilingual shift workforces.
- Integrated trending with configurable sample rates: The trend object supports sample intervals from 100 ms to 3,600 s per pen, with up to 8 pens per trend chart. Trend data is logged to the internal Flash and can be exported to USB in CSV format for offline analysis in process historians or spreadsheet tools.
- Diagnostic transparency via FactoryTalk Diagnostics: The terminal logs its own communication faults, tag subscription failures, and application errors to a local diagnostic buffer accessible via the terminal’s configuration menu. This self-diagnostic capability allows maintenance engineers to distinguish between controller-side faults and HMI-side communication issues without connecting a laptop to the panel network.
- USB-based application deployment: Application files compiled in FactoryTalk View ME Studio can be transferred to the terminal via USB Type A without a network connection. This is operationally significant for field service scenarios where the panel LAN is isolated from the engineering workstation network for cybersecurity reasons.
- NEMA 4X front-face rating for wash-down zones: The IP65-equivalent front seal allows the terminal to be mounted in food processing, pharmaceutical, and chemical wash-down zones without a secondary protective enclosure over the display — reducing panel depth requirements and improving operator ergonomics.
Quality Assurance & Global Logistics
Every Allen-Bradley 2711P-T10C4D1/A unit dispatched from our Xiamen, China facility undergoes a structured pre-shipment verification protocol. Each terminal is powered on and the FactoryTalk View ME runtime is confirmed to load correctly. The Ethernet port is tested for link negotiation at 10/100 Mbps. The touch overlay is calibrated and verified across a 9-point grid. Firmware version is documented and matched against the catalog revision (/A). Physical inspection covers connector integrity, bezel condition, and label legibility.
Units are packed in anti-static foam-lined cartons with silica gel desiccant packs and humidity indicator cards. Outer cartons are double-walled corrugated with corner protectors rated for the 15 g shock specification of the unit itself. Each shipment includes a packing list, test record, and — where applicable — original OEM documentation.
Logistics from Xiamen port to major global destinations: DHL Express to Europe (3–5 business days), FedEx International Priority to North America (3–5 business days), and regional freight options for Southeast Asia and the Middle East. Full export documentation including commercial invoice, packing list, and certificate of origin is prepared for every international shipment. HS Code 8537.10 applies for customs classification in most jurisdictions. All units carry a 12-month warranty from the date of shipment covering manufacturing defects and verified functional failures.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.