Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Allen-Bradley
Primary Part Number
2711PC-T10C4D8
Product Type
HMI Terminal
Series / Family
PanelView
Manufacturer
Allen-Bradley / Rockwell Automation
Country of Origin
US
Catalog Category
HMI Panels
Operating Temp.
0 °C to +55 °C
Warranty
12 months from date of shipment
Model confirmed for inquiry 2711PC-T10C4D8 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Allen-Bradley 2711PC-T10C4D8: 10.4″ DC-Powered Color Touchscreen Operator Terminal for Logix-Based Control Architectures

The 2711PC-T10C4D8 is a 10.4-inch resistive color touchscreen operator interface terminal within Rockwell Automation’s PanelView Plus Compact 1000 platform. Designed for machine-level HMI deployment, this unit operates on a 18–32 VDC supply rail and communicates natively with Logix-family controllers via EtherNet/IP — eliminating the middleware layer that adds latency and configuration overhead in third-party HMI architectures. Its pre-installed FactoryTalk View ME runtime enables direct tag-based data exchange with CompactLogix, ControlLogix, and MicroLogix 1400 controllers without additional software licensing at the panel level.

The terminal targets mid-complexity machine control panels where a 640×480 VGA display, sealed front face (IP65 / NEMA 4/4X), and compact panel cutout footprint are primary engineering constraints. It is deployed across discrete manufacturing, food and beverage processing, material handling, and OEM machine builder applications where deterministic HMI response and low panel integration cost are non-negotiable requirements.

📦 Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Part Number 2711PC-T10C4D8
Platform PanelView Plus Compact 1000
Manufacturer Allen-Bradley / Rockwell Automation
Display Size 10.4 in (diagonal)
Display Type Color TFT LCD
Resolution 640 × 480 px (VGA)
Touch Technology Resistive analog, single-touch
Input Voltage 18–32 VDC (nominal 24 VDC)
Power Consumption ≤ 25 W typical
Communication EtherNet/IP — RJ-45, 10/100 Mbps
USB Host Port 1× USB Type-A (application backup / restore)
USB Device Port 1× USB Type-B (PC programming / download)
Flash Memory 512 MB
RAM 128 MB
Operating System Windows CE 6.0
HMI Runtime FactoryTalk View ME (pre-installed)
Compatible FT View ME Versions v5.x – v8.x
Operating Temperature 0 °C to +55 °C
Storage Temperature -20 °C to +70 °C
Relative Humidity 5–95% RH, non-condensing
Front Face Protection IP65 / NEMA 4, 4X, 12, 13
Weight Approx. 1.1 kg
Certifications UL, cUL, CE, RCM
Warranty 12 months from date of shipment

Hardware Logical Analysis

The 2711PC-T10C4D8 is built on a single-board architecture running Windows CE 6.0 as a hard real-time-capable embedded OS. The resistive touchscreen digitizer operates on a 4-wire analog matrix: when pressure is applied, the controller samples X and Y voltage dividers at a fixed scan rate and resolves touch coordinates through an onboard ADC. This mechanism is inherently immune to EMI-induced false triggering that affects capacitive panels in high-frequency drive environments — a meaningful advantage in VFD-dense panels where radiated emissions in the 2–30 MHz band are common.

The EtherNet/IP stack on this terminal implements both explicit messaging (for configuration and non-time-critical data) and implicit I/O messaging (for cyclic tag updates). The FactoryTalk View ME runtime manages a local tag database that mirrors controller tags via CIP (Common Industrial Protocol) connections. Tag update rates are configurable per display object, allowing engineers to balance network bandwidth against display refresh latency — typically 100–500 ms for non-critical indicators and tighter for alarm-state objects.

The 512 MB flash storage holds the FactoryTalk View ME runtime, the application project file (.mer), and alarm/event log data. The USB host port provides a secondary application transfer path independent of the Ethernet network — critical for field service scenarios where network access is restricted. The USB device port exposes the terminal as a USB serial device to FactoryTalk View ME Studio, enabling direct project download without IP address configuration.

The 18–32 VDC input range accommodates voltage sag on 24 VDC panel rails under load — a common condition in panels with multiple 24 VDC consumers sharing a single power supply. The internal DC-DC converter maintains regulated logic supply voltage across this input range, preventing brownout resets during transient load events.

Front-face sealing to IP65 is achieved through a continuous gasket between the display bezel and the panel cutout surface. The rear enclosure is not rated for liquid ingress — the terminal must be mounted in a sealed enclosure for full environmental protection in washdown applications.

System Integration Benefits

  • Zero-middleware EtherNet/IP connectivity: Direct CIP tag browsing to Logix controllers eliminates OPC-DA/UA server configuration, reducing commissioning time and removing a failure point from the communication chain.
  • 24 VDC rail compatibility: The 18–32 VDC input range aligns with standard panel 24 VDC power supplies, removing the need for a dedicated AC transformer or secondary power supply in DC-powered panels.
  • Pre-installed FactoryTalk View ME runtime: No per-terminal runtime license purchase required. The application project (.mer file) is the only deliverable from the engineering workstation to the terminal.
  • Deterministic display refresh via CIP implicit messaging: Cyclic tag updates over EtherNet/IP provide predictable screen refresh behavior, supporting alarm response time requirements in safety-adjacent applications.
  • IP65 front face for harsh ambient conditions: Sealed against dust ingress and water jets per IEC 60529, enabling deployment in food processing, chemical, and outdoor-rated enclosure applications without additional protective covers.
  • Dual USB architecture for field serviceability: USB host port allows application backup and restore via flash drive without a laptop or network connection — reducing mean time to repair in field service scenarios.
  • FactoryTalk Alarms & Events integration: When configured, the terminal logs alarm states with timestamps to onboard flash, providing a local audit trail independent of the controller’s alarm buffer.
  • FactoryTalk ViewPoint compatibility: Web-based remote monitoring via FactoryTalk ViewPoint allows supervisory visibility of the HMI display from a browser on the same EtherNet/IP network — no additional hardware required.
  • Compact panel cutout footprint: Smaller cutout dimensions versus PanelView Plus 6 equivalents reduce enclosure size requirements and sheet metal cost in OEM machine panel designs.
  • Windows CE 6.0 OS stability: The embedded OS has a documented field history in industrial HMI applications exceeding a decade, with a deterministic process scheduler that prevents background OS tasks from interrupting HMI runtime execution.

Quality Assurance & Global Logistics

Each 2711PC-T10C4D8 unit dispatched from our Xiamen, China facility is sourced from verified supply channels with documented chain of custody. Pre-shipment inspection covers physical integrity of the housing and display, label authenticity verification against Rockwell Automation’s catalog markings, serial number traceability, and firmware version confirmation. Units exhibiting any sign of counterfeit labeling, physical damage, or firmware anomaly are quarantined and excluded from inventory.

Packaging follows anti-static and shock-absorption protocols: the terminal is wrapped in ESD-protective film, placed in foam-lined inner packaging, and shipped in a double-wall corrugated outer carton. For international shipments, we provide a complete documentation package: commercial invoice, packing list, HS code declaration (HS 8537.10), and Certificate of Origin. Expedited air freight via DHL Express, FedEx International Priority, or UPS Worldwide Express is available for time-critical requirements, with typical transit times of 3–7 business days to North America, Europe, and Southeast Asia from Xiamen Gaoqi International Airport.

All units carry a 12-month operational warranty from the date of shipment, covering verified functional defects under normal operating conditions. Warranty claims are processed within 5 business days of receipt of the returned unit. Extended warranty and on-site technical support agreements are available for volume procurement contracts.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.