Mitsubishi FX2N-64MR-001 PLC Module
Request verified availability, condition, replacement risk review, packing options and courier lead time for FX2N-64MR-001.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Mitsubishi Electric
- Primary Part Number
- FX2N-64MR-001
- Product Type
- PLC Module
- Series / Family
- MELSEC FX
- Country of Origin
- JP
- Catalog Category
- Relays & Protection
- Humidity
- 5–95% RH, non-condensing
FX2N-64MR-001 Down? Every Minute of Downtime Has a Price Tag — We Ship Today
Your line stopped. The HMI is dark. Maintenance pulled the base unit and confirmed it: the FX2N-64MR-001 is dead. You’ve already lost two hours of production. The shift supervisor is on your back. Procurement is quoting 6–8 weeks from the OEM channel — a timeline that exists in a different reality from yours right now.
This is exactly the scenario we stock for. At siemensplc.com, the Mitsubishi FX2N-64MR-001 is on the shelf in Xiamen, tested, documented, and ready to clear customs today. We’ve handled emergency replacements for automotive stamping lines in Germany, food packaging plants in Southeast Asia, and textile mills in Turkey — all with the same answer: ship first, paperwork follows.
The FX2N-64MR-001 is a 64-point relay output compact PLC from Mitsubishi Electric’s FX2N series — one of the most widely deployed small-to-mid-range controllers in global discrete manufacturing. With 32 DC inputs and 32 relay outputs, 8,000-step program memory (expandable to 16,000), and a 0.08 µs basic instruction cycle, this unit punches well above its physical size. Relay outputs mean true galvanic isolation between the controller and your field devices — critical when you’re switching inductive loads like solenoid valves, motor contactors, and pneumatic actuators.
The FX2N series reached end-of-life from Mitsubishi Electric, which means the OEM channel is dry. The aftermarket is flooded with counterfeits and refurbished units misrepresented as new. We source exclusively from verified distributor channels, and every unit leaving our warehouse carries a functional test report. If it doesn’t pass our bench test, it doesn’t ship — full stop.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Model | FX2N-64MR-001 | ✅ Ready to Ship |
| Brand | Mitsubishi Electric | |
| Series | FX2N | |
| Total I/O Points | 64 (32 IN / 32 OUT) | |
| Output Type | Relay (MR) — AC/DC, galvanic isolation | |
| Program Memory | 8,000 steps (expandable to 16,000 with memory cassette) | |
| Instruction Cycle | 0.08 µs / basic instruction | |
| Power Supply | 100–240 VAC, 50/60 Hz | |
| Communication | RS-422 built-in; optional 232-BD / 485-BD boards | |
| Max Expansion | 8 modules / 256 I/O total | |
| High-Speed Counters | 6 channels, up to 60 kHz | |
| Operating Temp | 0°C to 55°C | |
| Storage Temp | -25°C to 70°C | |
| Humidity | 5–95% RH, non-condensing | |
| Weight | Approx. 1,060 g | |
| Certifications | CE, UL, cUL | |
| Mounting | DIN rail (35 mm) | |
| Origin | Japan | |
| Condition | 100% Original, New | ✅ Verified |
Troubleshooting & Replacement Tips
Before you pull the unit, confirm the fault is actually the CPU base — not an expansion module or power supply. The FX2N-64MR-001 shares a 24 VDC service power rail with its expansion modules. A shorted FX2N-16EX or FX2N-4AD can drag down the entire rack and mimic a dead CPU. Disconnect all expansion connectors, power up the base unit alone, and check the POWER LED. If it lights and the RUN LED responds to the RUN/STOP switch, your base unit is alive — go hunting in the expansion chain.
Common fault indicators and what they actually mean:
- POWER LED off, no response: Check 100–240 VAC input at terminals L/N. Measure DC 24V at the service power terminals. If input voltage is present but POWER LED is dead, the internal switching PSU has failed — the base unit needs replacement.
- RUN LED flashing (1 Hz): CPU detected a watchdog timeout or program execution error. Connect GX Works2, read the error code from the special register D8060–D8069. Error 6000-series typically indicates a hardware fault; 7000-series points to a memory error — try clearing and reloading the program before condemning the unit.
- RUN LED solid, outputs not responding: Check output relay coil drive voltage at the Y-terminal commons. Relay contacts on the FX2N-64MR-001 are rated 2A/point at 250 VAC — sustained inductive loads without snubbers will burn contacts over time. Use a multimeter in continuity mode across each output terminal with the coil energized. A failed relay contact is a unit-level fault; individual relays are not field-replaceable.
- ERR LED on: Pull the error code via D8060. Code 6101 = I/O bus error (check expansion connectors). Code 6102 = I/O module count mismatch (an expansion module may have failed or been removed without updating the parameter settings in GX Works2).
- Battery low alarm (M8006 = ON): The FX2N-64MR-001 uses an FX-BATTERY (ER6VC119B, 3.6V lithium) to retain program memory and the real-time clock. Replace within 30 days of the alarm. Program backup to GX Works2 before battery swap — memory retention during swap is not guaranteed beyond 30 seconds.
Replacement procedure — what to do before the new unit arrives:
- Back up the existing program via GX Works2 (Project → Read from PLC). If the CPU is completely dead, check if a backup exists on the optional FX-EEPROM-32 memory cassette — it survives power loss and can be transferred directly to the replacement unit.
- Document all DIP switch settings on the existing unit. The FX2N-64MR-001 has no address DIP switches on the base unit itself, but if you have FX2N-232-BD or FX2N-485-BD communication boards installed, note the station number settings configured in the PLC parameters (GX Works2 → PLC Parameter → I/O Assignment).
- Label every expansion module connector before disconnecting. The FX2N expansion bus is positional — modules must reconnect in the same physical order or the I/O assignment table will mismatch.
- On the replacement unit, verify firmware version compatibility if you’re using FX2N-specific special function modules (e.g., FX2N-10PG positioning module). Firmware version is readable via D8001 after power-up.
- After program restore, force all outputs OFF in GX Works2 before switching to RUN mode. Verify each output point individually before releasing to automatic operation.
Reliability in Harsh Conditions
The FX2N-64MR-001 was engineered for the factory floor, not the server room. Mitsubishi Electric designed the FX2N series to operate continuously in environments that would kill consumer-grade electronics within weeks.
Vibration resistance: The unit is rated to IEC 61131-2 vibration standards — 10–57 Hz at 0.075 mm amplitude, 57–150 Hz at 9.8 m/s². In practice, this means it survives direct DIN-rail mounting on press machine frames, compressor skids, and conveyor drive panels without the PCB fatigue failures that plague cheaper alternatives. The relay output contacts are mechanically rated for 10 million operations under no-load conditions.
Thermal management: The operating range of 0°C to 55°C covers the vast majority of industrial panel environments. The internal design uses conformal-coated PCBs to resist condensation during temperature cycling — a common failure mode in outdoor enclosures and unheated warehouses. For installations approaching the 55°C ceiling, ensure panel ventilation provides at least 50 mm clearance above and below the unit and that ambient airflow is not blocked by cable bundles.
Electrical noise immunity: Relay outputs provide inherent isolation between the control circuit and the field circuit — no optocoupler degradation over time, no leakage current issues with high-impedance loads. The FX2N-64MR-001’s power supply section includes built-in noise filtering on the AC input, providing immunity to the voltage spikes and harmonic distortion common in heavy industrial power environments. For installations near large VFDs or welding equipment, add a line filter on the AC input and ensure the DIN rail is properly grounded to the panel earth bus.
Humidity and contamination: The 5–95% RH non-condensing rating is backed by conformal coating on critical PCB areas. Units stored in our Xiamen warehouse are kept in climate-controlled conditions with desiccant packaging — not stacked in an uncontrolled warehouse where humidity cycling causes flux residue activation and creep corrosion on connector pins.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian Province, China — one of the most logistics-efficient export cities on the mainland, with direct DHL, FedEx, and UPS gateway access. Here’s what the timeline actually looks like from the moment you confirm your order:
- Order confirmed before 14:00 CST: Same-day dispatch. The unit is packed, export documents generated, and handed to the carrier the same afternoon.
- DHL Express (most destinations): 2–4 business days to Europe, North America, Southeast Asia, and the Middle East. Real-time tracking from pickup to delivery.
- FedEx International Priority: 1–3 business days to the US and select European hubs. Recommended for the most time-critical shutdowns.
- Export documentation: Commercial invoice, packing list, and certificate of origin are prepared for every shipment. For EU customers, we provide EUR.1 movement certificates where applicable. HS code 8537.10 is used for PLC modules — a well-established classification that clears customs without delays at major ports.
- Customs clearance support: We provide pre-shipment documentation to your customs broker on request. For repeat customers, we maintain a standing product description template that accelerates clearance at your local port.
- Insurance: All shipments are fully insured at declared value. In the event of transit damage, we initiate a replacement shipment immediately — we don’t wait for the insurance claim to resolve before sending a replacement.
We’ve shipped to 60+ countries. The most common bottleneck is not the carrier — it’s the time between your line going down and you placing the order. The sooner you contact us, the sooner your line restarts.
Contact Information
📧 Email: [email protected]
💬 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.