Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330103-06-10-10-02-05 Proximity Transducer

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330103-06-10-10-02-05.

Exact part330103-06-10-10-02-05 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330103-06-10-10-02-05 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330103-06-10-10-02-05

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330103-06-10-10-02-05
Product Type
Proximity Transducer
Series / Family
3301
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
–35°C to +177°C (transducer body)
Model confirmed for inquiry 330103-06-10-10-02-05 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330103-06-10-10-02-05 — Stop the Clock on Your Downtime

Every minute a turbine or compressor train sits idle, the losses compound. A failed proximity transducer in a 3300 XL measurement chain is not a scheduled maintenance event — it is an emergency. The 330103-06-10-10-02-05 is the exact eddy-current sensing element your protection system needs back in the loop, and we stock it in Xiamen ready for same-day dispatch. No lead-time negotiation. No factory back-order queue. You call, we ship.

This is a 3300 XL 8mm proximity transducer with a 6-inch (152 mm) integral armored cable, reverse-mount 10-32 UNF thread, and a calibrated 200 mV/mil (7.87 V/mm) sensitivity. It drops directly into any 3300 XL monitor chain — 3300/16, 3300/20, 3300/25 — without recalibration. The part number is OEM-specified in GE, Siemens, Solar Turbines, and MAN Energy Solutions machinery documentation. If your DCS is throwing a transducer fault and your vibration channel has gone dark, this is the part that brings it back.

URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345

Quick Technical Datasheet

Parameter Value Status
Part Number 330103-06-10-10-02-05 Ready to Ship
Series 3300 XL 8mm Proximity Transducer System
Brand Bently Nevada (Baker Hughes)
Tip Diameter 8 mm
Cable Length 6 inches / 152 mm (integral armored)
Thread 10-32 UNF — Reverse Mount
Sensitivity 200 mV/mil | 7.87 V/mm
Linear Range 10–90 mil (0.25–2.29 mm)
Frequency Response DC to 10,000 Hz (–3 dB)
Supply Voltage –24 VDC nominal
Operating Temperature –35°C to +177°C (transducer body)
Target Material AISI 4140 steel (standard)
Output Type Voltage, negative slope, proportional to gap
Connector 10-32 coaxial, 3300 XL extension cable compatible
Approvals CE, CSA, FM (IS configurations available)
Weight ~80 g
Origin USA (Bently Nevada / Baker Hughes)
Dispatch Location Xiamen, China Ready to Ship

Troubleshooting & Replacement Tips

Fault scenario: Monitor channel shows NOT OK or vibration reading pegged at full scale. Before condemning the transducer, work the chain systematically. First, check the extension cable — the 330130-series cables are the most common failure point in high-vibration installations. Disconnect the cable at the monitor end and measure the transducer output voltage directly with a calibrated –24 VDC supply. At a 40 mil (1.0 mm) gap to an AISI 4140 target, you should read approximately –10.4 VDC ±0.5 V. If the reading is absent or erratic, the transducer is confirmed failed.

Replacement procedure — field notes:

  • De-energize the –24 VDC supply rail before disconnecting. The 3300 XL driver is not hot-swap rated at the transducer connector.
  • Record the existing gap voltage before removal. This is your baseline for re-gapping the replacement unit. Target gap is typically 50 mil (1.27 mm) for radial vibration probes unless the OEM drawing specifies otherwise.
  • The 10-32 UNF reverse-mount thread requires a probe holder with the correct bore. Do not attempt to adapt a standard-mount holder — the thread engagement depth differs and you will lose gap accuracy.
  • After installation, verify the gap voltage is within ±2 mV/mil of the original reading before re-energizing the monitor. A drift outside this tolerance indicates a target surface condition issue (rust, scoring, or non-ferrous contamination) rather than a transducer fault.
  • The -05 suffix denotes a specific coaxial connector termination. Confirm your extension cable connector matches before ordering. The -00 suffix variant uses a different termination and is not field-interchangeable without a cable adapter.
  • No firmware or DIP switch configuration is required on the 3300 XL monitor when replacing a like-for-like transducer. The monitor reads sensitivity from the measurement chain, not from a stored parameter. If replacing a different sensitivity transducer (e.g., 100 mV/mil), update the monitor sensitivity setting via configuration software.
  • Common fault codes on 3300/16 and 3300/20 monitors: OK relay de-energized + amber LED = gap out of range (re-gap required); OK relay de-energized + red LED = signal loss (cable or transducer open circuit); intermittent vibration spike = cable shield continuity issue, check the extension cable armor termination at both ends.

Reliability in Harsh Conditions

The 3300 XL 8mm transducer platform was not designed for a clean lab environment. It was engineered for the bearing housings of gas turbines running at 3,600 RPM in 45°C ambient, for the wet end of a seawater injection pump on an offshore platform, and for the hot section of an ethylene cracker where ambient temperatures routinely exceed 120°C. The 330103-06-10-10-02-05 reflects that design intent at every level.

The transducer body is machined from stainless steel with a hermetically sealed tip assembly. The integral armored cable uses a stainless-steel braid over a PTFE-insulated coaxial core — resistant to hydrocarbon fluids, steam condensate, and the mechanical abrasion that destroys standard instrumentation cable in rotating machinery environments. The coaxial connector is a precision 10-32 fitting with a positive-lock engagement that does not back out under vibration.

Operating temperature ceiling of +177°C at the transducer body means it survives direct contact with bearing housing surfaces that would destroy a standard industrial sensor. The eddy-current measurement principle is inherently immune to dust, oil mist, and humidity — there is no optical path to obscure, no contact surface to wear, and no moving part to fatigue. Units in continuous service on critical machinery trains routinely accumulate 80,000+ operating hours before replacement is warranted by calibration drift rather than failure.

Every unit we dispatch is bench-tested for output linearity and sensitivity against a calibrated gap simulation fixture. Sensitivity must fall within 200 mV/mil ±1% before the unit is cleared for shipment.

Global Express Logistics

Our warehouse is in Xiamen, Fujian — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international express networks. For emergency plant-down situations, we operate a same-day cutoff: orders confirmed before 15:00 CST ship the same business day. Standard export documentation — commercial invoice, packing list, and Certificate of Conformance — is prepared in parallel with packing and transmitted electronically before the courier collects.

Typical transit times from Xiamen: Southeast Asia 1–2 days, Middle East and Europe 3–4 days, North America 3–5 days, South America and Africa 5–7 days. For AOG-equivalent plant emergencies, we arrange DHL Express Priority with a next-flight-out option to major hub airports. Customs clearance support is available for all major import markets — we provide HS code documentation, origin certificates, and can prepare DDP shipments to eliminate your import burden entirely.

Packaging is anti-static, moisture-barrier sealed with foam-lined transit protection. The transducer tip and connector are individually capped. We have shipped to 60+ countries without a single transit damage claim on this product line.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.