Bently Nevada In Stock OK

Bently Nevada 330103-08-19-05-02-00 Proximity Transducer System

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330103-08-19-05-02-00.

Exact part330103-08-19-05-02-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330103-08-19-05-02-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330103-08-19-05-02-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330103-08-19-05-02-00
Product Type
Proximity Transducer System
Series / Family
3301
Country of Origin
US
Catalog Category
Sensors & Switches
Model confirmed for inquiry 330103-08-19-05-02-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330103-08-19-05-02-00 — Stop the Clock on Your Downtime. Ship Today from Xiamen.

Every hour your turbine or compressor sits idle, the losses compound. A tripped vibration channel, a failed Proximitor, a cracked probe tip — these are not maintenance events, they are financial emergencies. The Bently Nevada 330103-08-19-05-02-00 3300 XL 8mm Proximity Transducer System is on the shelf right now. We confirm stock, generate the commercial invoice, and hand it to DHL or FedEx the same business day. Your protection system is back online before your next shift change.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345


Quick Technical Datasheet

Part Number / SKU 330103-08-19-05-02-00  ✅ Ready to Ship
Brand Bently Nevada
Series 3300 XL Proximity Transducer System
Probe Diameter 8 mm
Extension Cable Body 19 mm
Interconnect Cable Length 5 metres
Output Signal –24 VDC nominal bias; linear range –2 VDC to –18 VDC
Sensitivity 7.87 V/mm (200 mV/mil)
Linear Measurement Range 0.25 mm – 2.26 mm (10 mil – 90 mil)
Frequency Response DC to 10,000 Hz (–3 dB)
Supply Voltage –24 VDC (–20 VDC to –26 VDC)
Current Draw ≤ 27 mA
Target Material (Standard) AISI 4140 steel — other alloys require recalibration
Probe Operating Temp –35 °C to +121 °C
Proximitor Operating Temp –35 °C to +66 °C
Ingress Protection IP67 (probe + extension)
Certifications API 670, CE, ATEX Zone 1/2, IECEx, FM, CSA
Connector MIL-C-5015 armored style
Country of Origin USA
HS Code 9031.80
Shipping Status ✅ In Stock — Same-Day Dispatch Available

Troubleshooting & Replacement Tips

Ten years of field calls teach you one thing: most 3300 XL failures are misdiagnosed. Before you condemn the probe, work through this sequence.

Step 1 — Verify the bias voltage first. Connect a calibrated DVM to the Proximitor output. Nominal gap bias should read between –10 VDC and –12 VDC at the machine’s cold, stationary gap. If you’re reading –24 VDC (rail high) or 0 VDC (rail low), the probe is either open-circuit or shorted — not necessarily failed. Check the extension cable connector seating before pulling the probe.

Step 2 — Isolate the three-component chain. The 330103-08-19-05-02-00 is a matched system: probe + 19mm extension + 5m interconnect + Proximitor. Swapping only the probe without replacing the matched extension will shift your calibration by up to 8%. Always replace as a matched set or re-verify sensitivity with a calibration target block after any partial swap.

Step 3 — Common fault codes on 3500 Series monitors.

  • OK LED off / Not OK relay energized: Bias voltage outside –2 to –18 VDC window. Check gap, cable continuity, and Proximitor supply rail (–24 VDC ±10%).
  • Intermittent trip on 1X vibration: Probe tip contamination (oil varnish, metallic debris). Clean with isopropyl alcohol. If runout exceeds 25% of full-scale, inspect shaft surface for mechanical damage.
  • Slow drift on DC gap channel: Thermal expansion of probe mounting bracket. Verify bracket material CTE matches casing. Re-gap at operating temperature if possible.
  • High noise floor on spectrum: Ground loop between Proximitor chassis and monitor rack. Verify single-point grounding per API 670 §6.3. Shield drain wire must be grounded at the monitor end only.

Step 4 — Replacement configuration checklist.

  • Confirm replacement probe is 8mm diameter — do not substitute 5mm (330101) or 11mm (330105) without reconfiguring the monitor channel scale factor.
  • Set the 3500 monitor channel sensitivity to 200 mV/mil (7.87 V/mm) — this is the factory default for 3300 XL 8mm systems.
  • Verify interconnect cable length matches the original (5m for this SKU). Changing cable length alters system calibration; use only the matched cable supplied with this part number.
  • After installation, perform a static gap check: adjust probe tip-to-shaft gap to achieve –10 to –12 VDC output at the Proximitor. This places the shaft in the center of the linear range.
  • No DIP switches or address coding required on the transducer itself — configuration is handled entirely at the 3500 monitor rack I/O module.
  • For ATEX installations: verify the Zener barrier or galvanic isolator is rated for the Proximitor’s input parameters before energizing in a hazardous area.

Reliability in Harsh Conditions

The 3300 XL platform was not designed for a clean instrument room. It was designed for the bearing pedestals of a 50 MW steam turbine running at 3,000 RPM in a tropical petrochemical plant — and it has to keep working when the ambient hits 55 °C, the humidity is 95%, and the maintenance crew is hosing down the deck.

The probe body is machined from 316 stainless steel with a hermetically sealed tip. The IP67 rating is not a marketing claim — it means the probe survives full immersion to 1 metre for 30 minutes. In practice, this translates to survival through steam purges, wash-down cycles, and condensation events that would destroy a standard sensor within weeks.

The armored MIL-C-5015 connector system resists vibration-induced loosening that plagues standard BNC or M12 connectors in high-cycle machinery environments. The extension cable jacket is rated for continuous exposure to lubricating oils, hydraulic fluids, and mild process chemicals without jacket degradation.

Vibration immunity is inherent to the eddy current operating principle — unlike piezoelectric accelerometers, there are no moving parts, no resonant elements, and no sensitivity to cross-axis shock. The system continues to output a valid DC gap signal even during high-amplitude vibration events that would saturate a conventional sensor.

Thermal cycling between –35 °C cold-start and +121 °C probe-tip operating temperature is handled by the matched calibration of the system. Factory calibration accounts for the thermal coefficient of the probe coil, ensuring sensitivity drift remains within ±1% over the full operating range — a specification that matters when your protection setpoints are set to 125 µm peak-to-peak.


Global Express Logistics

Our warehouse is located in Xiamen, China — one of the most logistics-efficient export hubs on the mainland, with direct DHL and FedEx gateway access. Here is exactly what happens after you place an urgent order:

  • T+0 (Order Confirmed): Stock physically verified and quarantined for your order. Commercial invoice, packing list, and Certificate of Conformance generated. Export classification confirmed (EAR99 — no license required for most destinations).
  • T+0 to T+4 hours: Unit packed in anti-static, shock-absorbing packaging. Outer carton labeled with HS code 9031.80 and declared value. Shipment booked with DHL Express or FedEx International Priority — carrier selected based on your destination for fastest transit.
  • T+4 to T+8 hours: Parcel collected by carrier and scanned into the international network. Tracking number issued to you immediately.
  • Transit Times (typical): Southeast Asia 1–2 days | Middle East 2–3 days | Europe 2–3 days | North America 3–4 days | South America / Africa 4–5 days.
  • Customs Documentation: Full export documentation provided. For destinations requiring an import permit or ATEX certification copy, documents are pre-prepared and included in the shipment envelope.

If your plant is in a remote location with customs clearance complexity, contact us before ordering. We have handled emergency shipments to offshore platforms, remote LNG terminals, and landlocked industrial zones — we know how to get the paperwork right the first time.


Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.