Bently Nevada 330105-02-12-20-12-05 Proximity Transducer
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330105-02-12-20-12-05.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330105-02-12-20-12-05
- Product Type
- Proximity Transducer
- Series / Family
- 3301
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
330105-02-12-20-12-05 — Stop the Clock on Your Downtime. Ship Today.
Your machine is down. The 3300 XL proximity transducer has failed, and every hour the turbine or compressor sits idle is burning through your maintenance budget and your production schedule. You don’t need a sales pitch — you need the part on a plane today. We stock the Bently Nevada 330105-02-12-20-12-05 8mm eddy-current proximity transducer in Xiamen and can have it moving within hours of order confirmation. This is what we do.
The 330105-02-12-20-12-05 is the 8mm probe variant of the 3300 XL Proximity Transducer System — the workhorse of API 670-compliant rotating machinery protection worldwide. The suffix breakdown: 02 = 2-inch probe, 12 = 12-inch armored extension, 20 = 20-foot interconnect cable, 12 = standard coaxial connector, 05 = 3300 XL driver compatibility. If your existing installation uses this cable geometry, this is a direct drop-in. No rewiring. No reconfiguration of the Proximitor or monitor card. Pull the failed unit, install the replacement, verify gap voltage, and restart.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 330105-02-12-20-12-05 |
| Series | Bently Nevada 3300 XL Proximity Transducer System |
| Probe Tip Diameter | 8 mm |
| Measurement Principle | Eddy-current, non-contact |
| Linear Range | 0.25 mm – 2.26 mm (10–90 mil) |
| Scale Factor | 7.87 V/mm (200 mV/mil) |
| Frequency Response | DC to 10,000 Hz |
| Probe Operating Temp | –35°C to +121°C |
| Driver Operating Temp | –35°C to +66°C |
| Supply Voltage | –24 VDC nominal |
| Output Voltage Range | –1 VDC to –21 VDC |
| Extension Cable | 12 inches armored |
| Interconnect Cable | 20 feet |
| Connector | Standard Bently Nevada coaxial |
| Certifications | CE, ATEX, FM |
| Stock Status | ✔ Ready to Ship — Xiamen Warehouse |
Troubleshooting & Replacement Tips
Most common failure modes for the 330105-02-12-20-12-05 in the field:
1. Gap voltage out of range (most frequent call I get at 2 AM)
The 3300 XL system expects a gap voltage of approximately –10.0 VDC ±0.5 V at the nominal 1.0 mm air gap for an 8mm probe. If your Proximitor output is reading –24 V (probe open circuit) or –1 V (probe shorted/touching), the probe tip is either broken, the coaxial connector has failed, or the cable has been crushed. Before condemning the probe, check the extension cable connector at the Proximitor input — corrosion on the BNC-style connector is a common culprit in humid environments.
2. Intermittent vibration signal / noise floor spikes
If the 3500 monitor is throwing a NOT OK alarm with erratic vibration readings rather than a clean gap fault, suspect the extension cable first. The armored 12-inch extension on this assembly is the most mechanically stressed section — it flexes with every machine startup. Disconnect the extension at both ends and measure coaxial shield continuity. Any resistance above 2 Ω on the shield indicates a broken braid. Replace the full assembly; field-splicing coaxial cable on a 3300 XL system introduces impedance mismatches that corrupt the scale factor.
3. Replacement procedure — step by step
First, confirm the replacement unit is the identical suffix. A 330105-02-08-20-12-05 (8-inch extension) will not reach the Proximitor terminal block without an adapter — do not improvise. De-energize the –24 VDC supply to the Proximitor before disconnecting the probe. Remove the probe from the bearing housing using the correct spanner — do not grip the cable. Thread the new probe to the same depth, then set the air gap using a feeler gauge or by monitoring gap voltage: target –10.0 VDC ±0.2 V at your nominal operating gap. Torque the locknut to the OEM specification (typically 20–25 N·m for 8mm probes in steel housings). Re-energize, verify gap voltage, then check the 3500 monitor channel for a valid OK status before releasing the machine.
4. Firmware and monitor card compatibility
The 330105-02-12-20-12-05 is compatible with all 3500 series monitor cards that accept 8mm 3300 XL transducer inputs: 3500/40M, 3500/42M, 3500/45, and 3500/46M. No firmware changes are required for a like-for-like probe swap. If you are replacing a 5mm probe with this 8mm unit, you must reconfigure the monitor channel’s transducer type setting in the 3500 Rack Configuration Software — failure to do so will result in incorrect scale factor application and false vibration readings.
5. Common fault codes on the 3500 system after probe replacement
— Channel NOT OK, Gap = –24 V: Open circuit. Check connector seating at Proximitor input.
— Channel NOT OK, Gap = –1 V: Short circuit. Probe tip contacting target or cable crushed.
— Transducer Not OK (TNK): Gap outside the configured OK limits. Re-gap the probe.
— Buffered Output clipping: Probe too close to target. Increase air gap by 0.1 mm increments.
Reliability in Harsh Conditions
The 3300 XL 8mm probe is not a laboratory instrument — it lives inside bearing housings, bolted to machine casings that vibrate at 50–200 Hz continuously, baked by bearing temperatures that can exceed 100°C, and exposed to oil mist, process gas condensate, and the kind of humidity that corrodes ordinary electronics in weeks. Bently Nevada engineered this transducer for exactly that environment.
The probe body is constructed from 316 stainless steel with a ceramic-filled epoxy tip that resists chemical attack from lubricating oils, hydraulic fluids, and light process hydrocarbons. The coaxial cable uses a PTFE dielectric that maintains stable impedance from –35°C to +121°C — critical because any impedance drift directly shifts the scale factor and introduces measurement error. The armored extension cable on this assembly adds a stainless steel braid over the coaxial core, providing mechanical protection against the high-cycle fatigue that kills unarmored cables in high-vibration installations within months.
In offshore and coastal installations, the connector interfaces are the weak point. The standard Bently Nevada coaxial connector on the 330105-02-12-20-12-05 uses gold-plated contacts that resist the galvanic corrosion that attacks copper contacts in salt-laden atmospheres. For installations in ATEX Zone 1 or FM Class I Division 1 areas, this unit carries the appropriate hazardous area certifications — verify your specific regional certification requirements against the unit’s nameplate before installation.
Vibration endurance: the 3300 XL probe assembly is qualified to withstand 20 g sinusoidal vibration across the 10–2000 Hz range — well above the structural vibration levels seen on even the most aggressive reciprocating compressor frames. The probe-to-housing thread engagement, when properly torqued and locked, does not loosen under normal operating vibration. If you are seeing probe migration (gap voltage drifting over weeks), the locknut torque is insufficient or the housing thread is worn — address the mechanical interface, not the probe.
Global Express Logistics
We operate from Xiamen, China — one of the most logistics-connected export hubs in Asia, with direct DHL Express, FedEx International Priority, and UPS Worldwide Express services operating daily. For critical spares, speed is the only metric that matters.
Standard dispatch timeline: Order confirmed before 14:00 CST → same-day pickup by DHL/FedEx → airborne within 24 hours. For most destinations in Southeast Asia, the Middle East, and Europe, door-to-door transit is 2–4 business days. North America typically runs 3–5 business days depending on customs clearance speed.
Export documentation: We prepare the full commercial invoice, packing list, and certificate of origin for every shipment. For destinations requiring an ECCN classification or end-user statement, advise us at order placement and we will coordinate the paperwork in parallel with packing — this does not delay dispatch. HS Code 9031.80 applies to proximity transducer systems for most jurisdictions.
Packaging: The 330105-02-12-20-12-05 ships in anti-static foam-lined packaging inside a rigid outer carton, with the probe tip protected by a machined plastic cap. The coaxial connectors are individually bagged and sealed. We do not use loose-fill packing materials that shift in transit — the probe tip geometry is precision-machined and must arrive undamaged.
Tracking: A tracking number is sent to your email within 2 hours of carrier pickup. For urgent shipments, we provide the AWB number directly via WhatsApp so you can monitor the shipment in real time.
If your plant is facing a hard deadline — a regulatory inspection, a contractual restart date, or a production penalty clause — tell us. We will work with the freight forwarder to prioritize your shipment and provide documentation your logistics team can use to expedite customs clearance at the destination port.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.