Bently Nevada 330130-080-11-00 Proximity Extension Cable
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330130-080-11-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330130-080-11-00
- Product Type
- Proximity Extension Cable
- Series / Family
- 3301
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- –40 °C to +85 °C
- Compliance
- API 670 (5th Ed.), CE, RoHS
330130-080-11-00 Extension Cable — Stop the Clock on Your Downtime
Every minute a turbine or compressor sits idle costs real money. When your Bently Nevada proximity loop goes dark — false high vibration trip, open-circuit fault on the extension cable, or a physical damage event during maintenance — the 330130-080-11-00 is the single part standing between you and restart. We stock it in Xiamen, we ship it today, and it lands on your skid before your next shift change.
This is not a generic cable. The 330130-080-11-00 is a factory-matched, impedance-controlled extension cable engineered specifically for the Bently Nevada 3300 XL and 7200 Series eddy-current proximity measurement systems. Swap it wrong and your gap voltage curve shifts. Swap it right — with this exact part number — and you walk away without touching the Proximitor calibration pot.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Part Number | 330130-080-11-00 ✔ Ready to Ship |
| Brand | Bently Nevada (Baker Hughes) |
| Series | 3300 XL / 7200 Series Proximitor® System |
| Cable Type | Standard Impedance-Matched Extension Cable |
| Cable Length | 8 meters (26.2 ft) |
| Connector Style | MIL-C-5015 armored, field-replaceable ends |
| Inner Conductor | PTFE-insulated, coaxial, impedance-matched to Proximitor driver |
| Outer Jacket | Stainless steel interlocked armor |
| Operating Temperature | –40 °C to +85 °C |
| Probe Compatibility | 3300 XL 8 mm, 11 mm, 14 mm; 7200 Series probes |
| Compliance | API 670 (5th Ed.), CE, RoHS |
| Weight | ~300 g |
| Stock Status | In Stock — Ships within 24 hours from Xiamen |
Troubleshooting & Replacement Tips
Fault scenario 1 — Proximitor output reads –24 V (open circuit). Before condemning the Proximitor module, disconnect the extension cable at both ends and measure coax continuity with a DMM. The 330130-080-11-00 armor is stainless steel but the inner coax is vulnerable at the connector crimp if the cable has been kinked or over-bent during a maintenance outage. A dead short or open on the center conductor is the #1 field failure mode for this part.
Fault scenario 2 — Vibration reading drifts high after cable replacement. This almost always means the replacement cable is a different length or a non-OEM part with mismatched capacitance. The 3300 XL Proximitor is calibrated as a three-component matched set: probe + extension cable + Proximitor. If you install a 5 m cable where an 8 m cable was specified, the gap voltage curve shifts and your alarm/trip setpoints are now wrong. Always replace like-for-like: 330130-080-11-00 for 330130-080-11-00.
Fault scenario 3 — Intermittent OK/Not OK on the monitor card. Check the connector seating at the Proximitor housing first. The MIL-C-5015 connector on this cable requires a firm quarter-turn lock. Vibration in the machine train can back the connector off over time. Torque to spec and apply thread-locking compound if the installation environment has high broadband vibration.
Replacement procedure (field-verified steps):
- De-energize the Proximitor supply rail — typically –24 VDC from the 3500 rack I/O module.
- Tag out the monitor channel and note the current OK/Not OK state for your work permit.
- Disconnect the extension cable at the probe end first, then at the Proximitor end. Never pull by the armor — grip the connector body.
- Route the new 330130-080-11-00 along the same conduit path. Do not coil excess cable — maintain the original routing geometry to avoid EMI pickup.
- Reconnect Proximitor end first, probe end second. Verify quarter-turn lock on both connectors.
- Re-energize and confirm gap voltage is within the linear range (typically –10 V ± 1 V at nominal gap). If gap voltage is outside range, verify probe gap with a feeler gauge before adjusting the Proximitor.
- Clear the monitor channel and confirm OK status. Log the replacement in your CMMS with the new cable serial number.
No firmware update required. The 330130-080-11-00 is a passive cable assembly. There are no DIP switches, no addressing, and no configuration steps. The only variable is physical routing and connector integrity.
Reliability in Harsh Conditions
Turbomachinery environments are brutal. The 330130-080-11-00 is built for exactly that. The stainless steel interlocked armor resists crush loads from cable trays, abrasion from adjacent piping, and the constant low-frequency vibration transmitted through the machine skid structure. In petrochemical plants where ambient temperatures routinely hit 60–70 °C at grade level, the PTFE inner insulation maintains its dielectric properties without softening or migrating — a failure mode common in cheaper PVC-jacketed alternatives.
In offshore and coastal installations, salt-laden air attacks connector contacts within months. The MIL-C-5015 connector on this cable uses gold-plated contacts and a sealed backshell that keeps moisture out of the coax termination. We have seen installations in Southeast Asian LNG terminals where this cable has run continuously for over eight years without a single replacement — not because it was forgotten, but because it simply did not fail.
High-humidity environments — paper mills, cooling tower decks, wet gas compressor stations — are where inferior cables fail first. The 330130-080-11-00’s armor-to-connector interface is sealed at the factory. There is no field-assembled crimp that can wick moisture into the coax. That factory seal is what separates a two-year cable from an eight-year cable in a wet environment.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. For urgent replacement orders, we operate a same-day cut-off: orders confirmed before 15:00 CST ship the same business day.
- DHL Express Worldwide — 2–4 business days to most of Europe, Middle East, and Southeast Asia. Door-to-door with real-time tracking from Xiamen to your receiving dock.
- FedEx International Priority — 1–3 business days to North America and Australia. Preferred for time-critical AOG-style industrial emergencies.
- UPS Expedited — cost-optimized option for non-critical replenishment orders where 5–7 day transit is acceptable.
All shipments include a commercial invoice, packing list, and certificate of origin. For customers in the EU, we provide EUR.1 movement certificates on request. For customers in the Middle East and India, we can provide a Chamber of Commerce-attested COO for customs clearance. Dangerous goods declaration is not required for this cable assembly — it ships as general cargo under HS code 8544.42.
We have shipped to refineries in Saudi Arabia, compressor stations in Kazakhstan, power plants in Vietnam, and paper mills in Finland. The logistics process is the same every time: confirm order, pick and pack, hand to courier, send tracking number within 2 hours of dispatch. No surprises.
Contact Information
📧 Email: [email protected]
📱 WhatsApp: +86 18359268345
🌐 Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.