Bently Nevada 330193-00-08-10-00 Proximity Probe
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330193-00-08-10-00.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330193-00-08-10-00
- Product Type
- Proximity Probe
- Series / Family
- 3301
- Manufacturer
- Bently Nevada (Baker Hughes)
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- -50 C to +177 C
330193-00-08-10-00 — Stop the Clock on Your Downtime: Same-Day Dispatch, Verified OEM Stock
Every minute a turbine or compressor sits idle costs real money — production losses, penalty clauses, idle crews. When your 3300 XL proximity probe fails, you don’t have time for a three-week lead time from the OEM. The Bently Nevada 330193-00-08-10-00 Extended Temperature Range Proximity Probe is on our shelf in Xiamen right now. We ship DHL Express within hours of order confirmation. That’s the difference between a four-hour outage and a four-day nightmare.
This is a 100% genuine Bently Nevada (Baker Hughes) unit — not a clone, not a refurb, not a “compatible” substitute. Full traceability documentation available on request. If you’re reading this at 2 AM during an emergency shutdown, here’s what you need to do first:
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 330193-00-08-10-00 | Ready to Ship |
| Manufacturer | Bently Nevada (Baker Hughes) | |
| Series | 3300 XL Extended Temperature Range (ETR) | |
| Probe Type | Eddy-Current Non-Contact Proximity Probe | |
| Tip Diameter | 8 mm | |
| Thread Size | 10-32 UNF | |
| Integral Cable Length | 8 inches (203 mm) | |
| Sensitivity | 200 mV/mil (7.87 V/mm) nominal | |
| Operating Temperature | -50 C to +177 C | |
| Supply Voltage | -24 VDC via Proximitor | |
| Output Range | -2 VDC to -18 VDC | |
| Linear Range | 0.25 mm to 2.25 mm (10 mil to 90 mil) | |
| Target Material | AISI 4140 / AISI 4340 steel | |
| Connector | Standard Bently Nevada coaxial | |
| Housing Material | 316 Stainless Steel | |
| Certifications | CE, CSA, FM Intrinsically Safe | |
| Compatible Proximitor | 3300 XL 8mm (330180-X0-05) | |
| Compatible Extension Cable | 330130 Series 5m or 9m | |
| Weight | Approx. 120 g | |
| Origin | USA (Bently Nevada OEM) | |
| Dispatch Location | Xiamen, China | Ready to Ship |
Troubleshooting and Replacement Tips
After handling hundreds of 3300 XL probe failures in the field, these are the patterns that show up again and again. Work through this list before you condemn the probe — and follow it precisely when you do swap it out.
Common Fault Signatures:
- 3500 rack Alert/Danger with no process change: First suspect is probe gap drift. Check DC gap voltage at the Proximitor output terminal. Nominal gap for most installations is -10 VDC (approx. 50 mil). Reading -2 V or -18 V means the probe tip is either touching the shaft or has pulled out of the bracket. Mechanical check before electrical.
- Intermittent OK/Not OK on the 3500 rack: 90% of the time this is a cracked cable jacket or a loose coaxial connector at the junction box. Flex the cable near the probe body while watching the Proximitor output. If the voltage jumps, the cable is the culprit. The 330193-00-08-10-00 has an integral 8-inch pigtail — damage here means full probe replacement.
- Sensitivity out of spec: Bench-test the probe against a calibrated target block using a 3300 XL Proximitor. If sensitivity has drifted more than 10%, the probe is degraded — common in ETR units that have seen sustained temperatures above 160 C for extended periods. Replace and recalibrate the full system.
- Not OK immediately after probe swap: You likely have a system mismatch. The 330193 is an 8 mm ETR probe — it must be paired with the 3300 XL 8mm Proximitor (330180 series), not the standard temperature version. Mixing ETR probes with non-ETR Proximitors produces a persistent Not OK even with a perfect probe.
- Gap voltage correct but vibration amplitude wrong: Check the extension cable length. The 330193-00-08-10-00 requires a matched 330130 extension cable (5m or 9m). Using a non-matched cable changes system inductance and throws off sensitivity calibration. Always use the matched system.
Step-by-Step Replacement Procedure:
- Step 1 — Isolate: Bypass the channel on the 3500 rack (inhibit alert/danger outputs) before disconnecting the probe. Pulling a live probe on a running machine triggers a spurious trip.
- Step 2 — Record the gap: Note the existing DC gap voltage before removal. Target is typically -10 VDC plus or minus 0.5 V unless the OEM specifies otherwise.
- Step 3 — Remove the probe: The 330193-00-08-10-00 uses 10-32 UNF thread. Use the correct probe wrench — no pliers on the housing. Back out slowly; on high-temperature installations the thread compound may have seized. Apply penetrating oil and allow 10 minutes before forcing.
- Step 4 — Inspect the bracket: Check the probe holder bore for debris, corrosion, or thread damage. A damaged holder misaligns the new probe and produces erratic readings. Clean with a thread chaser if necessary.
- Step 5 — Install the new probe: Apply a thin coat of anti-seize compound to the threads. Hand-tighten first, then torque to 1.1 N·m (10 in-lb) maximum. Over-torquing cracks the ceramic tip.
- Step 6 — Set the gap: Adjust probe depth until the Proximitor output reads your target gap voltage. Lock the locknut firmly. Re-check gap after locking — the probe can rotate slightly as the nut seats.
- Step 7 — Verify: Remove the inhibit on the 3500 rack. Confirm OK status, check alert and danger setpoints are active, and log the new gap voltage in your maintenance record.
Reliability in Harsh Conditions
The 330193-00-08-10-00 was built for environments that destroy ordinary sensors. The ETR designation reflects a fundamentally different construction approach compared to the standard 3300 XL probe line.
The probe body is machined from 316 stainless steel, resisting chloride-induced stress corrosion cracking in coastal and offshore installations. The cable jacket uses a high-temperature fluoropolymer compound rated to continuous service at 177 C — the same material class used in downhole oil and gas instrumentation. In practice, this means the probe survives the thermal cycling that kills standard probes: cold startup at -50 C, rapid ramp to operating temperature, sustained high-ambient operation near hot gas paths.
Vibration resistance is equally robust. The coaxial connector and integral cable assembly are mechanically secured at the probe body to prevent fretting fatigue — the failure mode that causes intermittent signals in high-vibration installations like reciprocating compressors and steam turbines running above 3,000 RPM. The ceramic-tipped probe face is impervious to the oil mist and process gas condensate that corrodes standard probe tips over time.
Humidity and ingress are handled by the sealed coaxial construction. There are no internal PCBs or active components in the probe itself — the eddy-current coil is a passive element encapsulated in chemically inert compound. No failure mode related to moisture ingress. In tropical and coastal installations where relative humidity regularly exceeds 95%, this passive construction is a significant reliability advantage over active sensor types.
The result is a mean time between failures measured in years, not months — which is why the 3300 XL ETR series remains the reference standard for API 670-compliant machinery protection systems in critical rotating equipment worldwide.
Global Express Logistics
Our dispatch hub is in Xiamen, China — one of the country’s primary export ports with direct DHL and FedEx gateway access. Here is exactly what happens after you place an order or send an RFQ:
- Hour 0-2: Order confirmed, stock allocated, export documentation prepared (commercial invoice, packing list, HS code 9031.80 for proximity sensors).
- Hour 2-4: Unit inspected, photographed, packed in anti-static foam with moisture-desiccant barrier. Tracking number generated and sent to you.
- Hour 4-8: Handed to DHL Express or FedEx International Priority at Xiamen gateway. For urgent orders placed before 14:00 CST, same-day handover is standard.
- Day 1-3: Transit to most destinations in Southeast Asia, Middle East, and Europe. North America typically 2-4 business days via FedEx International Priority.
- Customs clearance: We provide a complete export package — commercial invoice with accurate declared value, packing list, and Certificate of Origin on request. This eliminates customs holds that delay emergency shipments.
For customers in Singapore, Malaysia, India, UAE, Saudi Arabia, Germany, Netherlands, and the United States — we have established shipping lanes with consistent transit times. Bulk orders (5+ units) qualify for air freight consolidation with reduced per-unit shipping cost. We also support EXW, FOB Xiamen, and CIF terms for customers with their own freight forwarders.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved. All product names, trademarks, and part numbers are the property of their respective manufacturers and are used for identification purposes only.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.