Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330195-02-12-50-CN
- Product Type
- Proximity Probe
- Series / Family
- 3301
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Compliance
- API 670 Machinery Protection Standard
330195-02-12-50-CN — Stop the Clock on Your Downtime. Ship Today.
Your turbine is offline. The DCS alarm is screaming. Maintenance is standing by and every minute of lost production is burning through your budget. You already know the root cause: the proximity probe has failed, and without a verified replacement in hand, that machine stays cold. The Bently Nevada 330195-02-12-50-CN — an Extended Temperature Range (ETR) Reverse Mount eddy current probe from the 3300 XL 8mm Series — is on our shelf in Xiamen right now. We have processed emergency orders for power plants, refineries, and compressor stations across four continents. We know what urgency looks like, and we are built to respond to it.
This is not a catalog listing. This is a field-ready replacement unit. Inspected, documented, and packed for express air freight. If you submit your purchase order before 16:00 CST, it moves today.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number / SKU | 330195-02-12-50-CN |
| Brand | Bently Nevada (Baker Hughes) |
| Series | 3300 XL 8mm Proximity Transducer System |
| Probe Type | Reverse Mount, Extended Temperature Range (ETR) |
| Tip Diameter | 8 mm |
| Integral Cable Length | 12 inches (~305 mm), armored |
| Extension Cable Length | 50 inches (~1270 mm) |
| Connector Type | CN (coaxial, field-standard) |
| Mounting Style | Reverse Mount |
| Temperature Rating | Extended Temperature Range — high-temp process service |
| Target Compatibility | AISI 4140 steel; ferromagnetic and non-ferromagnetic metals (system-calibrated) |
| System Interface | Bently Nevada 3300 XL Proximitor® Sensor |
| Compliance | API 670 Machinery Protection Standard |
| Weight | ~40 g |
| Stock Status | ✅ Ready to Ship — Xiamen, China |
Troubleshooting & Replacement Tips
Most common failure modes for the 330195-02-12-50-CN in the field:
1. Gap voltage out of range (typical alarm: -10.0 V to -18.0 V window violated)
Before condemning the probe, check the Proximitor output with a calibrated voltmeter. A reading outside the linear range (-10.0 to -18.0 VDC for standard 8mm gap) usually points to one of three causes: probe tip contamination with conductive debris, mechanical contact between probe tip and shaft (gap collapsed), or a failed Proximitor sensor — not always the probe itself. Swap the Proximitor first if you have a spare; it is the cheaper and faster test.
2. Intermittent vibration signal / noise floor elevated
Armored cable integrity is the first suspect. Inspect the full cable run for pinch points, abrasion against hot surfaces, or connector corrosion at the CN junction. A megohm test between the center conductor and shield will reveal insulation breakdown that visual inspection misses. If resistance drops below 100 MΩ, the cable assembly is compromised — the 330195-02-12-50-CN ships as a probe-plus-integral-cable unit, so the entire assembly must be replaced.
3. Replacement configuration checklist — do not skip these steps:
- Gap setting: The 3300 XL 8mm system nominal gap is 1.0 mm (39.4 mil), corresponding to approximately -10.4 VDC Proximitor output. Set gap with a calibrated feeler gauge or dial indicator before energizing. Do not rely on the monitor alarm to confirm gap — it will not catch a gap that is close but outside the linear range.
- Reverse mount orientation: Confirm probe tip direction against your machine drawing before torquing the locknut. A reverse mount installed in a standard orientation will read inverted polarity — the monitor will see a positive-going signal on shaft movement that should be negative, triggering false alarms or masking real events.
- Extension cable matching: The 50-inch extension cable is integral to this part number. If your installation uses a separate extension cable (330130 series), verify total system cable length does not exceed the Proximitor’s specified range. Mismatched cable lengths shift the sensitivity (mV/mil) and invalidate calibration.
- ETR probe with standard Proximitor: The 330195 ETR probe is fully compatible with standard 3300 XL Proximitor sensors (330180, 330181). No firmware change or Proximitor swap is required when replacing a standard probe with an ETR variant in the same gap range.
- Post-installation verification: After installation, perform a static gap check and confirm Proximitor output is within the linear range. Then rotate the shaft by hand (if accessible) and verify the monitor displays a clean, noise-free vibration waveform before returning the machine to service.
- 3500 monitor channel configuration: If the replacement triggers a configuration mismatch alarm on the 3500 rack, navigate to the channel configuration in System 1 or the 3500 Rack Configuration Software and confirm the transducer type is set to 3300 XL 8mm. No other parameter change should be required for a like-for-like swap.
Common fault codes on the Bently Nevada 3500 rack when this probe fails:
- OK LED off / Not OK relay energized: Probe gap out of range or open circuit in cable — check gap and cable continuity first.
- Danger alarm with no process change: Probe tip contact with shaft or severe cable noise — inspect mechanically before assuming a real machine event.
- Buffered output signal clipped: Proximitor supply voltage issue — verify -24 VDC supply rail at the rack before replacing the probe.
Reliability in Harsh Conditions
The 3300 XL 8mm platform was not designed for laboratory conditions. It was designed for the inside of a gas turbine enclosure where ambient temperatures exceed 120°C, vibration levels are continuous, and the atmosphere carries hydrocarbon vapors and moisture. The ETR designation on the 330195-02-12-50-CN is not a marketing label — it reflects a validated operating envelope that standard probes cannot match.
The probe body is constructed from 316 stainless steel with a PEEK (polyether ether ketone) tip housing, chosen for its dimensional stability across wide temperature swings and its resistance to the chemical attack common in refinery and petrochemical environments. The armored integral cable uses a fluoropolymer jacket rated for continuous high-temperature service, with a stainless steel braid that provides both mechanical protection and EMI shielding in environments with large variable-frequency drives and high-current bus bars nearby.
Eddy current technology itself is inherently robust: there are no moving parts, no contact with the measured surface, and no wear mechanism. The probe will outlast the machine it monitors if the installation is correct and the cable is protected. Units we supply have been verified against OEM dimensional and electrical specifications — tip geometry, coil impedance, and cable integrity are all checked before the unit leaves our facility.
For installations in classified hazardous areas (Zone 1/Zone 2 or Class I Division 1/2), confirm that the Proximitor sensor in your system carries the appropriate ATEX or FM certification. The probe itself is passive and does not require independent hazardous area certification, but the complete system approval must be verified against your site classification.
Global Express Logistics
Our dispatch hub is in Xiamen, Fujian Province — one of China’s primary export ports with direct daily freight connections to DHL, FedEx, and UPS international hubs. This is not a drop-ship arrangement. The unit is physically in our warehouse, and we control the entire outbound process.
Standard express timeline from order confirmation:
- Same-day dispatch: Orders confirmed and paid before 16:00 CST ship the same business day via DHL Express or FedEx International Priority.
- Southeast Asia (Singapore, Malaysia, Thailand, Indonesia): 2–3 business days door-to-door.
- Middle East (UAE, Saudi Arabia, Qatar, Kuwait): 3–4 business days via DHL Express.
- Europe (Germany, Netherlands, UK, France, Italy): 3–5 business days via FedEx International Priority.
- North America (USA, Canada, Mexico): 3–5 business days via DHL Express or FedEx.
- South America and Africa: 5–7 business days; customs clearance timelines vary by country — contact us for country-specific guidance.
Every shipment includes a commercial invoice, packing list, and certificate of origin prepared to your customs requirements. For shipments to countries with import duty exemptions on industrial spare parts, we can provide the appropriate HS code documentation (HS 9026.80 for proximity measurement instruments). Air waybill tracking numbers are sent within 2 hours of dispatch. We do not use consolidated freight for urgent orders — your unit travels on the first available direct flight, not in a weekly consolidation.
For plant shutdowns with a hard restart deadline, contact us via WhatsApp for real-time coordination. We have managed emergency shipments with 24-hour door-to-door delivery to major industrial hubs in the Gulf and Southeast Asia. Tell us your deadline and we will tell you honestly whether we can meet it.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.