Bently Nevada 330903-00-20-05-02-CN Proximity Probe
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330903-00-20-05-02-CN.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330903-00-20-05-02-CN
- Product Type
- Proximity Probe
- Series / Family
- 3309
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- −35°C to +177°C
330903-00-20-05-02-CN: Stop the Clock on Your Downtime — Ship Today from Xiamen
Your turbine is down. The control room is on the phone. Maintenance is standing by. Every hour of unplanned shutdown on a rotating machine costs real money — and the bottleneck is almost always the same: waiting on parts. The Bently Nevada 330903-00-20-05-02-CN 5mm eddy-current proximity probe is one of the most frequently replaced components in any 3300 XL-based machinery protection system, and we keep it on the shelf precisely for moments like this.
We ship from Xiamen via DHL Express and FedEx International Priority. Most orders clear customs and land on your bench within 3–5 business days, regardless of whether you’re in Southeast Asia, the Middle East, or Europe. No waiting on factory lead times. No grey-market risk. Just a verified, original Bently Nevada probe ready to drop into your 3300 XL system and restore protection coverage.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification |
|---|---|
| Part Number | 330903-00-20-05-02-CN |
| Brand | Bently Nevada (Baker Hughes) |
| Series | 3300 XL Proximity Transducer System |
| Probe Type | Eddy-Current Non-Contact Proximity Probe |
| Tip Diameter | 5 mm |
| Cable Length | 2.0 m (integral) |
| Connector Type | CN (Coaxial) |
| Measurement Range | 0 – 2.54 mm (0 – 100 mil) |
| Sensitivity | 7.87 V/mm (200 mV/mil) |
| Bias Voltage (nominal) | −10.0 VDC |
| Operating Temperature | −35°C to +177°C |
| Target Material | AISI 4140 steel or equivalent |
| Approvals | CE, ATEX, FM (verify label) |
| Compatible Proximitor | Bently Nevada 330180 Series (5mm) |
| Compatible Extension Cable | Bently Nevada 330130 Series |
| Compatible Monitor | 3500/40M, 3500/42M, 3500/45 |
| Stock Status | Ready to Ship |
| Origin | United States |
Troubleshooting & Replacement Tips
The 330903-00-20-05-02-CN fails in predictable ways. Here is what to check before you pull the trigger on a replacement, and what to watch for during swap-out.
Common Fault Signatures:
- OK relay drops out, gap voltage reads rail-to-rail: Probe tip is shorted or the integral cable has a break near the connector. Flex the cable near the BNC end while watching the gap voltage — if it flickers, the cable is the culprit, not the probe body.
- 3500 system shows Not OK with gap voltage stuck at 0V or −24V: Confirm the Proximitor supply voltage is present (−24 VDC ±10%). A dead Proximitor will mimic a dead probe. Swap the Proximitor first if you have a spare — it is faster.
- High 1X vibration reading with no mechanical change: Check probe tip for surface contamination — oil varnish, metallic debris. Clean with isopropyl alcohol. If the reading does not normalize, the probe sensitivity has drifted — replace it.
- Intermittent Not OK alarms during startup: Thermal cycling can cause micro-fractures in the integral cable. If your installation exceeds 150°C ambient, inspect the cable jacket for cracking before condemning the probe.
Replacement Procedure — Key Steps:
- De-energize the channel at the 3500 rack before disconnecting. Do not hot-swap proximity probes on live machinery protection systems.
- Record the existing gap voltage before removal — typically −10.0 VDC ±0.5V at nominal air gap. This is your calibration reference for the new probe.
- The 330903-00-20-05-02-CN uses a 5mm tip. Confirm your Proximitor is the 330180 Series (5mm). Mixing 5mm probes with 8mm Proximitors (330185 Series) produces incorrect sensitivity and false readings.
- After installation, adjust the probe gap to achieve −10.0 VDC ±0.2V. Use a non-metallic feeler gauge or calibrated gap-setting tool. Do not rely on thread count alone.
- The 3300 XL system requires no firmware updates or address configuration for probe replacement — it is a passive transducer. No DIP switches, no addressing. The Proximitor handles all signal conditioning.
- Run a static calibration check using the 3500 rack built-in test function before returning the machine to service. Verify OK relay status and gap voltage simultaneously.
Reliability in Harsh Conditions
The 3300 XL proximity transducer system was engineered for continuous operation in the most demanding rotating machinery environments — petrochemical plants, offshore platforms, power generation facilities, and LNG terminals. The 330903-00-20-05-02-CN reflects that design philosophy in every detail.
The probe body is constructed from 316 stainless steel with a PEEK tip housing, providing resistance to hydrocarbon fluids, steam, and aggressive cleaning agents. The integral cable uses a fluoropolymer jacket rated for continuous exposure up to 177°C — well above the operating range of most bearing housings and turbine pedestals. The coaxial cable geometry maintains consistent impedance across the full temperature range, preventing sensitivity drift that would otherwise corrupt vibration readings.
Vibration resistance is built in. The probe assembly withstands 20g sinusoidal vibration across 10–2000 Hz, meaning the probe itself will not generate false signals even when mounted on a machine with severe mechanical looseness. The CN connector is secured with a locking collar to prevent intermittent contact from vibration-induced loosening — a failure mode that accounts for a disproportionate share of nuisance alarms in poorly maintained installations.
Moisture ingress is addressed through hermetic sealing at the probe tip and a fully potted cable termination. The probe can be submerged in oil or exposed to high-pressure wash-down without compromising measurement integrity. For ATEX Zone 1 or Zone 2 hazardous area installations, verify the specific approval code on the unit label against your area classification documentation before installation.
Global Express Logistics
Our Xiamen warehouse is positioned to serve industrial customers across Asia-Pacific, the Middle East, and Europe with the shortest possible transit times. Every order ships individually — no batch consolidation, no delays.
- DHL Express Worldwide: 2–4 business days to most destinations in Southeast Asia, Middle East, and Europe. Real-time tracking from pickup to delivery.
- FedEx International Priority: 3–5 business days. Preferred for North America and Australia.
- Export Documentation: Commercial invoice, packing list, and certificate of origin prepared for every shipment. For ATEX-certified units, EU Declaration of Conformity is included. HS code: 9031.80.
- Urgent Freight: For critical shutdowns requiring next-flight-out service, contact us via WhatsApp. Hand-carry courier from Xiamen to major hub airports can be arranged within 24 hours for confirmed orders.
- Bulk and MRO Orders: Dedicated stock reservation and priority allocation available. Contact us to discuss blanket purchase order terms.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.