Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Request Quote
Bently Nevada In Stock OK

Bently Nevada 330905-00-19-10-02-00 Proximity Probe

Request verified availability, condition, replacement risk review, packing options and courier lead time for 330905-00-19-10-02-00.

Exact part330905-00-19-10-02-00 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandBently Nevada Part Number330905-00-19-10-02-00 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 330905-00-19-10-02-00

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Bently Nevada
Primary Part Number
330905-00-19-10-02-00
Product Type
Proximity Probe
Series / Family
3309
Country of Origin
US
Catalog Category
Sensors & Switches
Operating Temp.
–35°C to +177°C (probe body); cable to +121°C
Compliance
API 670 5th Ed. · CE · RoHS
Model confirmed for inquiry 330905-00-19-10-02-00 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

330905-00-19-10-02-00 — Stop the Clock on Your Downtime

Every minute a turbine or compressor sits idle, the losses compound. A failed proximity probe shouldn’t be the reason your plant stays down for days. The Bently Nevada 330905-00-19-10-02-00 — a 19 mm eddy current proximity probe with 10-meter integral cable, calibrated for the 3300 NSv driver ecosystem — is on the shelf right now. We ship same day from Xiamen. You get it back online before the next shift change.

This isn’t a grey-market gamble. Every unit we dispatch is 100% original Bently Nevada, sourced with full traceability. The calibration is factory-intact. The connector seats clean. The cable jacket is uncompromised. You install it, zero it, and run — no surprises at 3 AM.

⚡ URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345


Quick Technical Datasheet

Part Number 330905-00-19-10-02-00
Brand Bently Nevada (Baker Hughes)
Series 3300 NSv Proximity Probe System
Probe Tip Diameter 19 mm (0.75 in)
Integral Cable Length 10 m (32.8 ft) — armored, PTFE-jacketed
Output Sensitivity 200 mV/mil (7.87 V/mm)
Linear Measurement Range 0 – 90 mil (0 – 2.29 mm); optimal 20–80 mil
Frequency Response DC to 10,000 Hz (–3 dB)
Supply Voltage –24 VDC nominal (3300 NSv driver)
Operating Temperature –35°C to +177°C (probe body); cable to +121°C
Target Material (calibrated) AISI 4140 steel — recalibrate for other alloys
Connector Code 02 — NSv standard BNC-compatible
Ingress Protection IP67 (probe tip and body)
Compliance API 670 5th Ed. · CE · RoHS
Country of Origin USA
Stock Status ✔ Ready to Ship — Xiamen Warehouse

Troubleshooting & Replacement Tips

Field experience with the 3300 NSv system surfaces the same failure patterns repeatedly. Here’s what to check before you pull the probe — and what to watch when you install the replacement.

Symptom: Monitor shows –24 V rail OK but probe output is stuck at –24 V (full-scale negative)
This is almost always an open circuit in the integral cable, not a failed probe tip. Flex the cable near the connector and near the probe body while watching the output. If the reading flickers, the break is mechanical — the probe assembly needs replacement, not just the driver. Part 330905-00-19-10-02-00 resolves this as a complete factory-calibrated assembly.

Symptom: Output voltage drifts slowly over a shift, alarm trips at 80 mil even though shaft position hasn’t changed
Check the driver’s oscillator frequency first (should be 1–2 MHz). Thermal drift in a failing driver can shift the carrier frequency, which changes the effective sensitivity. Swap the driver before condemning the probe. If the drift persists with a new driver, the probe tip has likely suffered thermal damage — common in installations within 50 mm of a bearing housing running above 150°C.

Symptom: High 1× vibration reading with no corresponding change in bearing temperature or process
Verify the probe tip gap. The 19 mm tip requires a minimum target diameter of approximately 50 mm for full linear range. On smaller shafts, the electromagnetic field wraps around the shaft edge and introduces a non-linearity that looks like vibration. Re-gap to 40–50 mil and recheck.

Replacement procedure — critical steps:

  • De-energize the –24 VDC supply to the driver before disconnecting the probe connector. Hot-swapping the BNC under power can spike the driver input and damage the oscillator circuit.
  • Do not cut or extend the 10 m integral cable. The probe + cable assembly is factory-calibrated as a matched set. Any splice introduces impedance mismatch that shifts the mV/mil output — your monitor will read incorrect gap values.
  • Confirm your driver part number is NSv-series (3300/16, /20, or /25). The NSv probe is NOT interchangeable with 3300 XL drivers — the calibration curves are different. Mixing them produces a systematic measurement error of up to 15%.
  • After installation, perform a static gap check: with the shaft stationary at the design gap (typically 40–50 mil), verify the driver output matches the expected voltage (8.0–10.0 V for 40–50 mil at 200 mV/mil). If it doesn’t, recheck the gap physically with a feeler gauge before assuming the probe is faulty.
  • If the target material is anything other than AISI 4140 steel (e.g., 17-4 PH stainless, Inconel, titanium), the probe requires recalibration against the actual target material. Running with the default calibration on a non-standard target can produce errors exceeding 20%.

Reliability in Harsh Conditions

The 330905-00-19-10-02-00 is not a lab instrument. It was designed for the inside of a turbine enclosure — where ambient temperatures swing from cold startup to sustained 150°C+ operation, where bearing oil mist coats every surface, and where the machine vibrates at frequencies that shake loose anything not properly secured.

The stainless steel probe body handles the thermal cycling without dimensional creep. The PTFE-jacketed armored cable resists hydrocarbon exposure, steam condensate, and the mechanical abrasion of cable trays that shift during thermal expansion. The IP67 rating on the probe tip and body means a pressure wash during a turnaround won’t compromise the assembly.

Vibration immunity is built into the eddy current measurement principle itself — there are no moving parts, no contact surfaces, no wear mechanisms. The probe generates a 1–2 MHz electromagnetic field and reads the reflected impedance change. The physics don’t degrade with operating hours. What fails in the field is almost always the cable (mechanical fatigue at the connector or probe body) or the driver (thermal stress on the oscillator circuit) — not the probe tip itself. When you replace the 330905-00-19-10-02-00 assembly, you’re replacing the most mechanically vulnerable component of the system with a fresh, factory-verified unit.

Units held in our Xiamen warehouse are stored in temperature-controlled, low-humidity conditions with connector caps installed. Shelf life is indefinite under these conditions. Every unit dispatched passes a physical inspection: tip condition, cable jacket integrity, connector seating torque, and label legibility. Functional verification — a gap vs. output voltage sweep test — is available on request for critical applications.


Global Express Logistics

Our dispatch hub is in Xiamen, China — one of the country’s primary export ports with direct DHL and FedEx gateway access. When you place an urgent order before 14:00 CST, the unit ships the same business day. Here’s what the timeline looks like in practice:

  • Order confirmed → Packed and labeled: Within 2 hours of payment clearance
  • Xiamen → DHL/FedEx gateway: Same day pickup, 17:00–19:00 CST
  • Southeast Asia (SG, MY, TH, ID): 2–3 business days door-to-door
  • Middle East (AE, SA, QA): 3–4 business days
  • Europe (DE, NL, GB, FR): 3–5 business days
  • North America (US, CA): 4–6 business days
  • Australia / New Zealand: 4–5 business days

All shipments include a commercial invoice, packing list, and HS code declaration (HS 9031.80 — instruments for measuring or checking). For US-bound shipments, EAR99 classification documentation is provided. For customers requiring a Certificate of Conformance or material traceability documentation, these are prepared and included in the shipment package at no additional charge.

We track every shipment proactively. If a customs hold occurs, we engage the broker directly and notify you within 24 hours. You don’t chase paperwork — we do.


Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.