Bently Nevada 330908-00-16-10-02-05 Proximity Probe
Request verified availability, condition, replacement risk review, packing options and courier lead time for 330908-00-16-10-02-05.
Click Request Quote and the part number is inserted into the inquiry form automatically.
- Reply by email: [email protected]
- WhatsApp / Tel: +86 18359268345
- Mon-Sat 9:00-18:00 GMT+8
Key Product Information
Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.
- Brand
- Bently Nevada
- Primary Part Number
- 330908-00-16-10-02-05
- Product Type
- Proximity Probe
- Series / Family
- 3309
- Country of Origin
- US
- Catalog Category
- Sensors & Switches
- Operating Temp.
- −35°C to +177°C
- Compliance
- API 670, IEC 61511, ISO 20816, CE, RoHS
330908-00-16-10-02-05 — Stop the Clock on Your Downtime. Ship Today.
Every hour a turbine or compressor sits idle costs real money — production losses, penalty clauses, idle crews. The Bently Nevada 330908-00-16-10-02-05 proximity probe is one of the most frequently replaced wear items in 3300/3500-series machinery protection systems, and when it fails, you need a verified unit on a plane, not a two-week lead time from a regional distributor. We stock this part in Xiamen and can have it moving via DHL Express within hours of order confirmation.
URGENT REQUIREMENT? Contact: [email protected] | WhatsApp: +86 18359268345
Quick Technical Datasheet
| Parameter | Specification | Status |
|---|---|---|
| Part Number | 330908-00-16-10-02-05 | ✔ Ready to Ship |
| Brand | Bently Nevada | |
| Series | 3300 NSv (Non-Standard Voltage) | |
| Sensing Technology | Eddy Current, Non-Contact | |
| Probe Tip Diameter | 16 mm (5/8 in) | |
| Integral Cable Length | 1.0 m (3.3 ft), armored | |
| Extension Cable Code | 02 — Standard | |
| Connector Code | 05 — BNC/Coaxial | |
| Linear Measurement Range | 0.25 mm – 2.25 mm (10 – 90 mil) | |
| Scale Factor | 7.87 V/mm (200 mV/mil) nominal | |
| Frequency Response | DC to 10,000 Hz | |
| Supply Voltage | −24 VDC via Proximitor® driver | |
| Operating Temperature | −35°C to +177°C | |
| Housing Material | 316 Stainless Steel | |
| Target Material (Standard) | AISI 4140 Steel | |
| Weight | ~60 g | |
| Compliance | API 670, IEC 61511, ISO 20816, CE, RoHS | |
| Origin | USA |
Troubleshooting & Replacement Tips
The 330908-00-16-10-02-05 fails in predictable ways. Here is what to check before you pull the probe and what to verify when you install the replacement:
Common Fault Signatures:
- OK LED extinguished on the 3300/3500 monitor, alarm relay energized: First suspect the probe tip gap. Measure the Proximitor® output voltage — nominal is −10.0 VDC at 1.0 mm gap. A reading outside −2 V to −18 V window indicates probe or driver failure, not a process event.
- Intermittent high-vibration trips with no process correlation: Inspect the integral cable at the probe body exit — this is the highest-stress point. Micro-fractures in the coaxial shield cause noise spikes that the monitor interprets as vibration. Flex the cable gently while watching the raw voltage output; any flicker confirms cable damage.
- Constant −24 V output (rail voltage): Open circuit — probe tip is broken or the coaxial center conductor is severed. Replace the probe. Do not attempt field repair on the integral cable.
- Output stuck at 0 V: Short circuit between center conductor and shield. Usually caused by moisture ingress at the connector or physical crush damage to the cable. Inspect the BNC connector O-ring and replace if hardened.
- Drift over temperature: NSv probes are factory-calibrated for non-standard target alloys (Inconel, titanium, duplex SS). If the shaft material was changed during a previous overhaul and the probe was not re-specified, scale factor mismatch will cause apparent drift. Confirm target material against the probe’s calibration certificate.
Replacement Procedure — Key Steps:
- De-energize the Proximitor® driver before disconnecting the probe. The −24 VDC supply is live at the connector when the driver is powered.
- Record the existing probe gap (feeler gauge or dial indicator) before removal. The replacement probe must be re-gapped to the same nominal — typically 1.0 mm (40 mil) — and the Proximitor® output voltage verified at −10.0 ± 0.5 VDC before returning the machine to service.
- Do not reuse the probe mounting thread sealant. Clean the threads and apply fresh Loctite 243 or equivalent medium-strength threadlocker. Torque to the bracket manufacturer’s specification — over-torquing the stainless body into a steel bracket will gall the threads.
- Route the replacement cable with a minimum bend radius of 25 mm. Avoid routing adjacent to high-voltage cables or VFD output conductors — induced noise will corrupt the low-level analog signal.
- After installation, perform a static gap check and a slow-roll vibration baseline before loading the machine. Document the Proximitor® output voltage and compare against the previous baseline in your historian.
Reliability in Harsh Conditions
The 330908-00-16-10-02-05 is not a laboratory instrument — it is built to survive the environments that destroy lesser sensors. The 316 stainless steel housing resists the sulfurous condensates found in gas turbine bearing pedestals and the chloride-laden atmospheres of coastal LNG terminals. The armored integral cable withstands continuous vibration at the probe body without fatigue failure at the frequencies generated by typical rotating equipment (10–300 Hz fundamental, harmonics to 10 kHz).
Operating temperature ceiling of +177°C covers the majority of hot-section bearing pedestal installations where ambient temperatures routinely exceed 120°C during full-load operation. The eddy current sensing element itself has no moving parts and no wear mechanism — the only failure modes are mechanical damage to the cable or housing, moisture ingress at the connector, or target material mismatch. All three are installation and maintenance issues, not product reliability issues.
Bently Nevada’s manufacturing process for the 3300 NSv series includes 100% factory calibration of each probe against a traceable reference standard. Scale factor is verified at multiple gap points across the full linear range before the unit leaves the factory. This means the probe you install will perform identically to the one it replaces — no field calibration required, no adjustment to the monitor trip setpoints.
Global Express Logistics
Our warehouse is located in Xiamen, Fujian Province — one of China’s primary export hubs with direct access to DHL, FedEx, and UPS international gateways. For urgent replacement orders, the typical process is:
- Order confirmation before 14:00 CST: Same-day dispatch via DHL Express Worldwide or FedEx International Priority.
- Transit times: Southeast Asia 1–2 business days; Middle East and Europe 2–3 business days; North America 3–4 business days; South America and Africa 4–5 business days.
- Export documentation: Commercial invoice, packing list, and certificate of origin are prepared for every shipment. HS Code 9031.80.9090 is pre-declared. For customers requiring a certificate of conformance or material traceability record, request at time of order.
- Customs clearance: We declare accurate values and correct HS codes on every shipment. We do not under-declare. This protects you from customs holds that would defeat the purpose of express shipping.
- Tracking: AWB number provided within 2 hours of dispatch. Real-time tracking link sent to your email.
For volume orders (5+ units), blanket purchase orders, or consignment stock arrangements, contact us directly — we can discuss dedicated inventory allocation to eliminate lead time entirely for your site.
Contact Information
Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
© 2026 siemensplc.com. All rights reserved.
Send This Part Number to Sales
Confirmation Process
We check the full part number, brand, series and visible nameplate information before quotation.
Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.
DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.