Siemens PLC sourcing desk · Multi-brand automation spares [email protected] +86 18359268345
Siemens In Stock OK

Siemens 6AV2143-6GA00-0SN0 HMI Touch Panel – SIMATIC TP1500 Comfort

Request verified availability, condition, replacement risk review, packing options and courier lead time for 6AV2143-6GA00-0SN0.

Exact part6AV2143-6GA00-0SN0 RFQ auto-fillPart number attached Export packingDHL / FedEx / UPS Sales replyEmail or WhatsApp
BrandSiemens Part Number6AV2143-6GA00-0SN0 ConditionAvailability Check Lead TimeRFQ Confirmation DocumentsDatasheet / photos by RFQ ShippingExport packing available
Auto-filled RFQ 6AV2143-6GA00-0SN0

Click Request Quote and the part number is inserted into the inquiry form automatically.

Procurement Data

Key Product Information

Core fields for model confirmation and RFQ routing. Detailed product narrative remains below.

Brand
Siemens
Primary Part Number
6AV2143-6GA00-0SN0
Product Type
HMI Touch Panel
Series / Family
SIMATIC
Country of Origin
DE
Catalog Category
HMI Panels
Operating Temp.
0 °C to +50 °C (horizontal mounting); 0 °C to +40 °C (vertical)
Warranty
12 months from shipment date
Model confirmed for inquiry 6AV2143-6GA00-0SN0 Send quantity, destination and urgency. The RFQ form keeps this part number attached.
Request Quote
Product Overview

Siemens 6AV2143-6GA00-0SN0 — 15.4″ SIMATIC HMI TP1500 Comfort: Operator Interface Architecture for High-Density PROFINET Environments

The 6AV2143-6GA00-0SN0 is a 15.4-inch widescreen resistive multi-touch operator panel belonging to Siemens’ SIMATIC HMI Comfort Panel generation. Within a distributed control architecture, this unit occupies the visualization and operator-interaction layer, serving as the primary interface between field-level process data and plant personnel. Its role is not decorative — it is a deterministic data endpoint that reads and writes PLC tags via PROFINET RT/IRT, renders process graphics at configurable refresh cycles, manages alarm queues with timestamped acknowledgment, and logs operational data to removable media or upstream SCADA/MES systems.

The panel is configured exclusively through Siemens TIA Portal (WinCC V13 SP1 minimum), which means the HMI project shares a unified engineering database with the connected S7-1200/1500/300/400 PLC. Tag bindings, alarm definitions, and communication parameters are resolved at compile time — not at runtime — eliminating the class of integration errors common in third-party HMI-PLC pairings. For system integrators managing multi-panel installations, this translates directly into reduced commissioning hours and a single-source audit trail for functional safety documentation.

Real-time Stock & RFQ: [email protected] | WhatsApp: +86 18359268345

Technical Parameters

Parameter Specification
Order Number (MLFB) 6AV2143-6GA00-0SN0
Series SIMATIC HMI Comfort Panel
Display Type 15.4″ TFT Widescreen LCD
Resolution 1280 × 800 px (WXGA)
Color Depth 24-bit (16.7 million colors)
Backlight LED, adjustable brightness
Touch Technology Resistive analog multi-touch
Processor ARM Cortex-A8, 600 MHz
Project Memory 24 MB (internal flash)
User Data Memory 64 MB (internal flash)
Operating System Windows CE 6.0
PROFINET Ports 2 × RJ45, 10/100 Mbit/s, auto-MDI/MDIX
Serial Interface 1 × RS-422/485 (MPI / PROFIBUS DP, up to 12 Mbit/s)
USB Ports 2 × USB 2.0 Type-A (host)
Memory Card Slots 1 × SD/SDHC, 1 × CF (CompactFlash)
Supply Voltage 24 V DC (permissible range: 20.4–28.8 V DC)
Rated Current Draw ≤ 1.5 A @ 24 V DC
Power Consumption Approx. 30 W (typical operating)
Inrush Current ≤ 15 A (< 5 ms)
Protection Rating (Front) IP65 per IEC 60529
Protection Rating (Rear) IP20 per IEC 60529
Operating Temperature 0 °C to +50 °C (horizontal mounting); 0 °C to +40 °C (vertical)
Storage Temperature -20 °C to +60 °C
Relative Humidity 10–90% RH, non-condensing
Vibration Resistance 5–9 Hz: 3.5 mm amplitude; 9–150 Hz: 1 g (IEC 60068-2-6)
Shock Resistance 15 g / 11 ms (IEC 60068-2-27)
Dimensions (W × H × D) 404 × 272 × 56 mm
Panel Cutout (W × H) 380 × 248 mm (ref. doc A5E02479740)
Weight Approx. 4.45 kg
Mounting Orientation Landscape or portrait, panel-mount
Configuration Tool SIMATIC WinCC (TIA Portal) V13 SP1 or higher
Max. PLC Connections 8 simultaneous (PROFINET + MPI/PROFIBUS combined)
Certifications CE, UL, cULus, RCM, KC
Country of Origin Germany
Warranty 12 months from shipment date

Hardware Logical Analysis

The 6AV2143-6GA00-0SN0 integrates a dual-port PROFINET switch at the physical layer, implemented via an embedded ERTEC 200 ASIC. This architecture allows the panel to participate in Media Redundancy Protocol (MRP) ring topologies without an external managed switch — a meaningful cost and latency reduction in ring-redundant machine networks. The two RJ45 ports share a single MAC address from the network perspective but support independent cable paths, so a single cable fault does not interrupt HMI-PLC communication.

The resistive touch sensor uses a four-wire analog matrix overlaid on the TFT glass. Unlike projected capacitive sensors, resistive technology responds to any stylus — gloved hands, metal probes, or standard fingertips — without calibration drift under EMI. The touch controller samples at approximately 100 Hz and applies a configurable debounce filter (1–255 ms) to suppress false triggers from panel vibration, a common failure mode in press-room and stamping-line installations.

EMC performance is governed by the panel’s internal shielding topology: the display assembly, CPU board, and power supply are separated by grounded aluminum partitions. The 24 V DC input passes through a common-mode choke and transient voltage suppressor (TVS) array rated to IEC 61000-4-5 Level 3 (2 kV line-to-earth surge). The PROFINET ports include transformer-coupled isolation with 1500 V AC dielectric strength, preventing ground loop currents from corrupting Ethernet frames — a failure mode frequently observed in long cable runs across multi-building industrial sites.

The ARM Cortex-A8 processor at 600 MHz runs WinCC Runtime under Windows CE 6.0. Screen refresh is handled by a dedicated 2D graphics accelerator, offloading pixel rendering from the main CPU. This separation ensures that a computationally intensive alarm evaluation cycle does not degrade display frame rate — a critical requirement in process plants where operators must read trend curves and acknowledge alarms simultaneously during upset conditions.

System Integration Benefits

  • Unified TIA Portal Engineering: HMI and PLC projects share a single tag namespace. Changes to PLC data blocks propagate automatically to HMI tag bindings during compilation, eliminating manual cross-referencing and the associated documentation errors.
  • PROFINET IRT Support: Isochronous Real-Time (IRT) communication with jitter below 1 µs enables synchronized data acquisition between the HMI and motion-control axes — relevant for press-line and packaging machine applications where operator displays must reflect actual servo positions without perceptible lag.
  • MPI/PROFIBUS DP Backward Compatibility: The RS-422/485 port supports MPI at 187.5 kbit/s and PROFIBUS DP at up to 12 Mbit/s, allowing the panel to connect directly to legacy S7-300 and S7-400 CPUs without protocol converters. This preserves existing PLC investments during phased modernization projects.
  • Alarm Management with IEC 62682 Alignment: WinCC Runtime supports alarm classes, priorities, and shelving functions consistent with IEC 62682 / ISA-18.2 alarm management standards. Alarm logs with millisecond timestamps are stored to SD/CF card and can be exported in CSV format for post-incident analysis.
  • Recipe Management: Up to 500 recipes with 1000 data records each can be stored on removable media. Recipe transfer to/from PLC data blocks is executed via structured WinCC recipe views, reducing operator parameter-entry errors in batch production.
  • VNC Remote Access: The built-in VNC server (password-protected) allows remote visualization from any VNC client on the plant network. No additional software license is required for read-only remote monitoring — useful for shift supervisors reviewing process status from a control room PC.
  • OPC UA Server (License Upgrade): With a WinCC Runtime Advanced license, the panel exposes an OPC UA server endpoint, enabling direct data exchange with MES/ERP systems without a dedicated SCADA gateway. This reduces the middleware layer count and associated latency in production reporting workflows.
  • Diagnostic Transparency: The panel reports its own hardware status (backlight hours, CPU temperature, memory utilization) via PROFINET diagnostics readable in TIA Portal’s online device view. Predictive maintenance schedules can be based on actual backlight operating hours rather than fixed calendar intervals.

Quality Assurance & Global Logistics

Every 6AV2143-6GA00-0SN0 unit dispatched from our Xiamen, China facility is a genuine Siemens-manufactured product sourced through verified industrial automation supply channels. Each unit undergoes a pre-shipment inspection protocol that includes: power-on functional test at 24 V DC, display uniformity and backlight verification, PROFINET port link-up confirmation, touch calibration check, and serial number documentation against the shipping manifest.

Original Siemens packaging, firmware labels, and where available, factory documentation are preserved intact. The serial number and firmware version are recorded and provided to the buyer with each shipment, enabling full traceability for quality audits and warranty claims.

Warranty coverage is 12 months from the shipment date. Dead-on-arrival (DOA) units are replaced within 7 business days of confirmed fault report. For non-DOA warranty claims, the RMA process is initiated within 24 hours of fault documentation receipt.

Logistics from Xiamen port to global destinations is handled via DHL Express, FedEx International Priority, or sea freight consolidation depending on order volume and buyer timeline. Export documentation — commercial invoice, packing list, certificate of origin, and HS code declaration (8537.10) — is prepared for every shipment. Typical DHL Express transit times: Southeast Asia 2–3 days, Europe 4–6 days, North America 5–7 days, Middle East 4–5 days. Expedited same-day dispatch is available for in-stock units when orders are confirmed before 14:00 CST.

Contact Information

Email: [email protected]
WhatsApp: +86 18359268345
Web: siemensplc.com
Location: Xiamen, China
© 2026 siemensplc.com. All rights reserved.

Ready to quote

Send This Part Number to Sales

[email protected]
RFQ workflow

Confirmation Process

Quality workflow ->
01Model confirmation

We check the full part number, brand, series and visible nameplate information before quotation.

02Availability reply

Sales confirms stock path, condition option, quantity and realistic lead time for export dispatch.

03Packing & courier

DHL, FedEx, UPS or buyer courier arrangements can be reviewed with packing requirements.